Ericsson ASB 150 02 Description page 12

Fault tracing description
Table of Contents

Advertisement

Uppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved
2.2.3
LEDs on other Boards
LED
Condition
LEDs in
red
RP disconnects PCM
connection
bus and signalling
field 2
interface from back
(upper
plane
part)
yellow This LED indicates if
the board is in start-up
procedure or if the
board (individual) is
blocked.
green Individual is active
LEDs in
yellow Register is blocked
connection
field 2
(lower
part)
green Register is active
Faktaansvarig - Subject responsible
Kontr/Checked
Correction
This can occur if the CP on the CPU is restarted or a board failure is
detected by the RP. Check if it concerns just one or more board(s). A
watchdog reset on the board could cause a board restart. System
supervision will invoke a system restart if major faults occur. If LED is
continuously ON check if the yellow and green LEDs flash, otherwise
the RP is not working.
This condition is normal for a start-up sequence indicating initialisation
or running self test. If this LED is ON during operation, this indicates
blocking of one or more individual(s). The proper action is to check the
wiring and if the connected equipment is operational (check it's alarm
indication).
This indicates normal system operation and at least one e.g. extension
(individual) is active on the board.
This indicates that the register function on the board is blocked e.g. on
BTU-D or VMU-HD.
This indicates normal system operation. This register function is active
on the board e.g. on BTU-D or VMU-HD.
FAULT TRACING DESCRIPTION
Dokumentnr/Documentnr
1545-ASB 150 02 Uen
Datum/Date
Rev
1999-07-15
F
12(42)