CHANGING THE BATTERIES When battery life display on the FLM-3 begins to blink and the unit starts to beep, this will indicate that it’s time to replace the batteries. Open the bottom cover of the device, removed the batteries and insert new batteries while matching proper positioning.
Page 3
HOW TO USE THE FLM-3 1. Insert the 1/4” hose into to the fitting on unit. 2. Remove the battery discharge protection tab which is located on the bottom of the unit in order to turn the power on. 3. Press the “SET” button and hold for 3 seconds in order to select the preferred unit of measurement (LPM or GPM).
FEATURES The FM-200 is an easy-to-install flow monitor that enables you to check and measure flow rates in Liters Per Minute (LPM) or Gallons Per Minute (GPM). This product enables users to manage clean water when a water purifier filter expiration date is set to match the flow rate capacity. A user can set a specific flow rate limit, and if the flow rate exceeds the set limit, an alarm will sound along with an icon that will appear on the display screen.
INSTALLATION INSTRUCTIONS CONT’D How to Insert the Hose: Insert the hose towards the direction where the arrow points to install. How to Remove the Hose: While pressing the grey ring, pull the hose towards the direction where the arrow points to separate the hose. LCD SCREEN DESCRIPTION Liters Liters...
BUTTON EXPLANATION Power “ON/OFF”. Move the shift button to the right in order to choose digits when setting an alarm. Increases the number of the selected digit when setting an alarm. Press and hold to speed up. Accesses the flow rate, “SET” mode, entry and save features. Press and hold for 3 seconds or order to switch measurement units from liters to gallons and vice versa.
Page 7
ALARM SETTING FEATURE If the cumulated flow rate exceeds the limit that the user originally set, the water flow alarm will beep 5 times and the alarm icon on the LCD display will blink. In this case, change your water purifier filter and reset the unit.
The warranty does not cover water damage to the FLM-3 due to parts not securely closed. Products with any evidence of such damage will not be repaired or replaced.