iseg EBS Technical Documentation Manual

iseg EBS Technical Documentation Manual

Bipolar 4 quadrant high voltage module with common floating ground cfg

Advertisement

Quick Links

Technical documentation
Last changed on: 26.03.2020
EBS
Bipolar 4 Quadrant High Voltage Module with Common Floating Ground (CFG)
full 4-quadrant capabilities, usable as bipolar current sink and source
perfect for electron optical systems and capacitive loads
low ripple and noise
hardware voltage and current limit
programmable parameters (delayed trip etc.)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EBS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for iseg EBS

  • Page 1 Technical documentation Last changed on: 26.03.2020 Bipolar 4 Quadrant High Voltage Module with Common Floating Ground (CFG) full 4-quadrant capabilities, usable as bipolar current sink and source • perfect for electron optical systems and capacitive loads • low ripple and noise •...
  • Page 2: Document History

    Copyright © 2020 by iseg Spezialelektronik GmbH / Germany. All Rights Reserved. This document is under copyright of iseg Spezialelektronik GmbH, Germany. It is forbidden to copy, extract parts, duplicate for any kind of publication without a written permission of iseg Spezialelektronik GmbH. This information has been prepared for assisting operation and maintenance personnel to enable efficient use.
  • Page 3: Safety

    Advices marked as “Caution!” describe actions to avoid possible damages to property. CAUTION! INFORMATION Advices marked as “Information” give important information. INFORMATION Read the manual. Attention high voltage! Important information. EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 3/22...
  • Page 4: Intended Use

    You may only put the product into operation after it has been established that the high-voltage device complies with • the country-specific regulations, safety regulations and standards of the application. The high-voltage power supply unit may only be installed by qualified personnel. • EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 4/22...
  • Page 5: Important Safety Instructions

    Do not operate the unit in an explosive atmosphere. WARNING! WARNING! Do not operate the unit if you suspect the unit or the connected equipment to be damaged. WARNING! EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 5/22...
  • Page 6 When controlling, with software, the high voltage systems, make sure that nobody is near the high voltage or can be injured. Caution! INFORMATION Please check the compatibility with the devices used. INFORMATION EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 6/22...
  • Page 7: Table Of Contents

    4.2 SLP – Internally powered safety loop Front panel versions Dimensional drawings Limits and Jumper Connectors and PIN assignments Accesories Order guides Appendix Glossary Warranty & Service Disposal Manufacturer contact EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 7/22...
  • Page 8: General Description

    4-quadrant capabilities. The EBS can be used as bipolar current sink and source, which perfectly meets the requirements of electron optical systems or capacitive loads. The EBS is built in common floating ground principle to reduce voltage noise level.
  • Page 9: Technical Data

    Notes: The resolution of measurable values depends on the settings of the sampling rate and the digital filter! Standard factory settings Table 1: Technical data: Specifications EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 9/22...
  • Page 10: Handling

    Typically newer iseg crate controllers (CC24, CC23, CC238) are delivered with 250kBits/s standard. INFORMATION Wiener M-POD Controller and older iseg hardware is set on 125 kBit/s standard bitrate. EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com...
  • Page 11: Module Status

    (the corresponding bits are always set). The loop can be activated by removing the jumper “SL-disable” on the rear side of the module, see 6 Dimensional drawings. EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 11/22...
  • Page 12: Delayed Trip

    SL when a trip is detected. 4.2 SLP – Internally powered safety loop Internal current source for the Safety Loop (no galvanic isolation of the SL and the crate GND). EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 12/22...
  • Page 13: Front Panel Versions

    5 Front panel versions FRONT PANELS Channels 12 / 24 Floating HV Connector Options Figure Table 5: Front panel versions EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 13/22...
  • Page 14: Dimensional Drawings

    6 Dimensional drawings Figure 1: dimensional drawing 3U Figure 2: dimensional drawing 6U SHV EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 14/22...
  • Page 15: Limits And Jumper

    Figure 3: dimensional drawing 6U REDEL 7 Limits and Jumper Figure 4: limits and jumper 3U Model EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 15/22...
  • Page 16: Connectors And Pin Assignments

    Table 6: HV Connector SAFETY LOOP Name Safety Loop socket Figure LIMIT MONITOR Name Limit monitor socket Figure Table 7: Safety Loop and Limit Connector (drawings not to scale) EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 16/22...
  • Page 17 EGG.0B.304.CLL Connector FGG.0B.304.CLAD52 Safety Loop (LEMO) Socket ERA.0S.302.CLL Connector FFA.0S.302.CLAC / Z592312 Limit monitor 2pol. (LEMO) Socket EGG.00.302.CLL Connector FGG.00.302.CLAD Table 8: Connectors part number information EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 17/22...
  • Page 18: Accesories

    9 Accesories CAUTION! Only use genuine iseg parts like power cables, CAN cables and terminators for stable and safe operation. CAUTION! ACCESSORY ITEM ORDER ITEM CODE REDEL coupling Socket, without contacts Z200325 REDEL Socket contact, ERA.05.403.ZLL1 Z592263 REDEL SL sockets Contact, EGG.3B.665.ZZM Z592262 REDEL socket carrier red SLA.H51.LLZG...
  • Page 19: Order Guides

    504 = 500µA information) Redel Multipin For Example: (see Table 8: SLP = 002 Connectors part number information) Table 10: Item code parts for different configurations EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 19/22...
  • Page 20: Appendix

    11 Appendix For more information please use the following download links: This document http://download.iseg-hv.com/SYSTEMS/MMS/EBS/iseg_datasheet_EBS_en.pdf CAN EDCP Programmers-Guide http://download.iseg-hv.com/SYSTEMS/MMS/CAN_EDCP_Programmers-Guide.pdf iseg Hardware Abstraction Layer http://download.iseg-hv.com/SYSTEMS/MMS/isegHardwareAbstractionLayer.pdf EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 20/22...
  • Page 21: Glossary

    Reference temperature HV ON/OFF HV OFF/ON channel(s) high voltage low voltage signal ground Inhibit Polarity KILL KillEnable EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 21/22...
  • Page 22: Warranty & Service

    15 Manufacturer contact iseg Spezialelektronik GmbH Bautzner Landstr. 23 01454 Radeberg / OT Rossendorf GERMANY FON: +49 351 26996-0 | FAX: +49 351 26996-21 www.iseg-hv.com info@iseg-hv.de sales@iseg-hv.de EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 22/22...