Technical documentation Last changed on: 26.03.2020 Bipolar 4 Quadrant High Voltage Module with Common Floating Ground (CFG) full 4-quadrant capabilities, usable as bipolar current sink and source • perfect for electron optical systems and capacitive loads • low ripple and noise •...
Advices marked as “Caution!” describe actions to avoid possible damages to property. CAUTION! INFORMATION Advices marked as “Information” give important information. INFORMATION Read the manual. Attention high voltage! Important information. EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 3/22...
You may only put the product into operation after it has been established that the high-voltage device complies with • the country-specific regulations, safety regulations and standards of the application. The high-voltage power supply unit may only be installed by qualified personnel. • EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 4/22...
Do not operate the unit in an explosive atmosphere. WARNING! WARNING! Do not operate the unit if you suspect the unit or the connected equipment to be damaged. WARNING! EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 5/22...
Page 6
When controlling, with software, the high voltage systems, make sure that nobody is near the high voltage or can be injured. Caution! INFORMATION Please check the compatibility with the devices used. INFORMATION EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 6/22...
4.2 SLP – Internally powered safety loop Front panel versions Dimensional drawings Limits and Jumper Connectors and PIN assignments Accesories Order guides Appendix Glossary Warranty & Service Disposal Manufacturer contact EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 7/22...
4-quadrant capabilities. The EBS can be used as bipolar current sink and source, which perfectly meets the requirements of electron optical systems or capacitive loads. The EBS is built in common floating ground principle to reduce voltage noise level.
Notes: The resolution of measurable values depends on the settings of the sampling rate and the digital filter! Standard factory settings Table 1: Technical data: Specifications EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 9/22...
Typically newer iseg crate controllers (CC24, CC23, CC238) are delivered with 250kBits/s standard. INFORMATION Wiener M-POD Controller and older iseg hardware is set on 125 kBit/s standard bitrate. EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com...
(the corresponding bits are always set). The loop can be activated by removing the jumper “SL-disable” on the rear side of the module, see 6 Dimensional drawings. EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 11/22...
SL when a trip is detected. 4.2 SLP – Internally powered safety loop Internal current source for the Safety Loop (no galvanic isolation of the SL and the crate GND). EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 12/22...
5 Front panel versions FRONT PANELS Channels 12 / 24 Floating HV Connector Options Figure Table 5: Front panel versions EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 13/22...
6 Dimensional drawings Figure 1: dimensional drawing 3U Figure 2: dimensional drawing 6U SHV EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 14/22...
Figure 3: dimensional drawing 6U REDEL 7 Limits and Jumper Figure 4: limits and jumper 3U Model EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 15/22...
Table 6: HV Connector SAFETY LOOP Name Safety Loop socket Figure LIMIT MONITOR Name Limit monitor socket Figure Table 7: Safety Loop and Limit Connector (drawings not to scale) EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 16/22...
Page 17
EGG.0B.304.CLL Connector FGG.0B.304.CLAD52 Safety Loop (LEMO) Socket ERA.0S.302.CLL Connector FFA.0S.302.CLAC / Z592312 Limit monitor 2pol. (LEMO) Socket EGG.00.302.CLL Connector FGG.00.302.CLAD Table 8: Connectors part number information EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 17/22...
9 Accesories CAUTION! Only use genuine iseg parts like power cables, CAN cables and terminators for stable and safe operation. CAUTION! ACCESSORY ITEM ORDER ITEM CODE REDEL coupling Socket, without contacts Z200325 REDEL Socket contact, ERA.05.403.ZLL1 Z592263 REDEL SL sockets Contact, EGG.3B.665.ZZM Z592262 REDEL socket carrier red SLA.H51.LLZG...
504 = 500µA information) Redel Multipin For Example: (see Table 8: SLP = 002 Connectors part number information) Table 10: Item code parts for different configurations EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 19/22...
11 Appendix For more information please use the following download links: This document http://download.iseg-hv.com/SYSTEMS/MMS/EBS/iseg_datasheet_EBS_en.pdf CAN EDCP Programmers-Guide http://download.iseg-hv.com/SYSTEMS/MMS/CAN_EDCP_Programmers-Guide.pdf iseg Hardware Abstraction Layer http://download.iseg-hv.com/SYSTEMS/MMS/isegHardwareAbstractionLayer.pdf EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 20/22...
Reference temperature HV ON/OFF HV OFF/ON channel(s) high voltage low voltage signal ground Inhibit Polarity KILL KillEnable EBS High Voltage Power Supply series | Last changed on: 26.03.2020 | www.iseg-hv.com 21/22...
Need help?
Do you have a question about the EBS and is the answer not in the manual?
Questions and answers