4. CONTENTS
Item No
Description
1
Control Box
2
Wall Bracket
3
Self Tapping Screw ST4 X 30
4
Plastic Wall Plug
5
Thumb Screw M6 X 12
6
Remote Controller
5. INSTALLATION
5.1.
WALL MOUNTING (fig.1).
IMPORTANT! The heater should always have a minimum clearance of 300mm from a ceiling and at least 1000mm from any
object. Ensure that the mounting surface is capable of supporting the weight of the heater.
5.1.1. Using the wall bracket (2) as a template, drill the wall and insert suitable wall fixings (4). NOTE: Minimum height for lower fixing screws
1600mm.
5.1.2. Secure the metal bracket to the wall using screws (3).
5.1.3. Register vertically the heater assembly (1) on to the wall bracket (2) and clamp when in position using the thumb screw (5).
5.1.4. Adjust the angle of heater to direct heat where required.
6. OPERATION
Note: The infrared lamp is fragile and therefore it is important that it is not subjected to any unnecessary shocks or vibration and is not moved
when it is on or still warm. Only move once completely cooled down.
WARNING! Ensure you read, understand and apply the safety instructions in Section 1 before using the heater.
6.1.
Ensure the heater is at least 1000mm from any object. The heater can be tilted from 0° to 25°, set it to the required angle before switching
the heater on.
6.2.
Plug in the heater and switch it on using either the control on the base of the heater or by using the remote.
6.3.
The heater will start on the low setting, each press of the on/power button will cycle the heater onto the medium setting, high setting and
then back to the low setting.
6.4.
When the heater is no longer required, switch off, using the off button on the unit or the off button on the remote and unplug the unit.
NOTE: When switching off using the remote, the heater and lights will be in stand by mode.
6.5.
The heater has a built in tilt switch safety mechanism that switches off the unit if it is tilted beyond 25° either forwards or backwards. This
prevents fire in the event of the unit being knocked over. If the unit does not turn on again when returned to the vertical, tip it
approximately 25° in the opposite direction until you hear the internal switch operate. As the heater switches on return it to the vertical
position.
7. MAINTENANCE
7.1.
Make sure the heater plug is disconnected from the mains supply before any cleaning is attempted. Also allow the heater to cool
completely. DO NOT use water or other liquids, or harsh abrasive cleaners to clean the heater. DO NOT touch the carbon fibre elements
with your fingers as this may damage the tube.
7.2.
Clean the exterior with a soft damp cloth and some mild detergent.
7.3.
To replace any of the elements or lamps, contact your authorised Sealey dealer.
7.4.
To change the remote control batteries, press down and push back the battery cover (fig.2), remove old batteries and replace with two new
AAA batteries.
WARNING! DO NOT mix old and new batteries and dispose of old batteries in accordance with local authority regulations.
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500.
R
ecycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a
recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential
purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak's registered
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
© Jack Sealey Limited
Qty
1
1
4
4
1
1
unserviceable and requires disposal and dispose of the product according to local regulations.
Dispose of this product at the end of its working life in compliance with the EU Directive on
of in an environmentally protective way. Contact your local solid waste authority for recycling information.
Battery Removal: see section 5.4. for battery removal details.
compliance scheme. Jack Sealey Ltd's Batteries Producer Registration Number (BPRN) is BPRN00705
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
fig.2
Environmental Protection
WEEE Regulations
01284 757500
01284 703534
.
www.sealey.co.uk
sales@sealey.co.uk
IWMH2003RC.V2
Issue:3(MB) - 09/12/15

Advertisement

loading