Extra Information On Operation Of The Dvld; Averaging Time & Distance Thresholds - Davicom DVLD-1 User Manual

Lightning detector
Table of Contents

Advertisement

19) Of particular interest is the display of data trending with the 1LD01 variable. Simply putting
it into the Input ID of a Trending graph object will produce a display as shown below. Note
that you must log-off after setting this up, the data will appear in the graph the next time
you log back on.

5 Extra information on operation of the DVLD

5.1 Averaging time & distance thresholds
Independently of the Davicom's settings, the DVLD's internal circuit is always operating and
actively listening for the electromagnetic signature of lightning strikes. It can detect both cloud-
to-ground and cloud-to-cloud strikes. If the hardware-based averaging and distance estimation
DVLD User Manual