K3G250-PR17-I5
4.3.3 Cable routing
No water may penetrate along the cable in the direction of the cable gland.
NOTE
Damage caused by moisture penetration.
Moisture can penetrate into the terminal box if water is
constantly present at the cable glands.
→ To prevent the constant accumulation of water at the cable
glands, the cable should be routed in a U-shaped loop
(siphon) wherever possible.
→ If this is not possible, a drip edge can be produced by
fitting a cable tie directly in front of the cable gland for example.
Fig. 2: Fan installed lying flat, cable routed in a U-shaped loop.
When routing the cable, ensure that the screwed cable glands are
arranged at the bottom. The cables must always be routed downwards.
Fig. 3: Cable routing for fans installed upright.

4.4 Factory settings

Factory settings with which the device is pre-set by ebm-papst.
Control mode
PWM controlling
parameter set 1
Control mode
PWM controlling
parameter set 2
Fan / device adress
1
Max. PWM / %
100
Min. PWM / %
10
Save set value to
No
EEPROM
Set value control
Analogue (linear)
Control function
Positive (heating)
parameter set 1
Item no. 54783-5-9970 · ENG · Revision 202174 · Release 2018-12-28 · Page 8 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Control function
parameter set 2
Positive (heating)