Having completed the adjustment of collar frequency, pressing the Accept button yields the following figure:
In the above figure the tubing joint count to liquid level 149.62 is the most accurate value for the depth to the
liquid level. The accuracy of the indicated depth of 4842 ft is dependent on the accuracy of the Average Joint
length that the user has entered in the well information. Note that in this case the operator input value of 31.69
feet/joint is being used in the depth calculation.
Once a change has been made to an Automatic Analysis, notice the screen title changes to reflect Manual
Liquid Level Depth Analysis.