Page 2
Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
IDENTIFICATION ID MAX.U500i Contents Contents Contents Safety Instructions Performance Features of ID MAX.U500i Performance Features ....................... 6 myAXXESS Manager ......................6 Available Reader Types ....................6 Scope of Delivery Installation Terminals Antenna Connection ......................13 Power Supply ........................14 5.2.1 Power Supply via Connector X2 ................
Page 4
IDENTIFICATION ID MAX.U500i Contents Buzzer ..........................25 Reader Power Adjustment ....................25 Positioning of the Antenna Mounting of the Transponder Technical Data Radio Approvals 10.1 Europe (CE) ........................31 10.2 USA (FCC) and Canada (IC) .................... 32 10.2.1 USA (FCC) and Canada (IC) Warning Notices ..........32 10.2.2 Installation with FCC/IC Approval ..............
IDENTIFICATION ID MAX.U500i 1 Safety Instructions 1 Safety Instructions Safety Instructions ► The device may only be used for the intended purpose designed by the manufacturer. ► The manual should be conveniently kept available at all times for each user. ►...
IDENTIFICATION ID MAX.U500i 2 Performance Features 2 Performance Features of ID MAX.U500i Performance Features 2.1 Performance Features With its compact size, its weather-resistant housing, a read range of 8 to 10 m and the circular-polarized antenna supporting any transponder orientation, the UHF Vehicle Access Control Reader ID MAX.U500i is ideally suited to provide efficient and secure vehicle access control.
IDENTIFICATION ID MAX.U500i 3 Scope of Delivery 3 Scope of Delivery Scope of Delivery The scope of delivery includes following components: 1 x ID MAX.U500i 1 x MFD 25/01/065 M25 multiple sealing insert for 1 cable; cable ∅ 4–6.5 mm •...
(see Fig. 4), that should be fixed with screw locking varnish, and e.g. a wire rope. The suitable accessory ID ANT.UEB-A can be purchased from FEIG ELECTRONIC. Fig. 1: Dimensional drawing – back view...
IDENTIFICATION ID MAX.U500i 4 Installation Fig. 4: Secondary protection via eye bolt NOTE: FEIG ELECTRONIC GmbH strongly recommends to secure the reader against falling by means of an eye bolt to prevent damage. Page 11 of 36...
IDENTIFICATION ID MAX.U500i 5 Terminals 5 Terminals Terminals The cable connections are located on the lower side of the reader. Fig. 5 shows the arrangement of the connectors and Table 1 gives an overview on the available connectors and interfaces. Table 2 lists the available operating and display elements.
IDENTIFICATION ID MAX.U500i 5 Terminals 5.1 Antenna Connection The TNC socket for connecting the external antenna is located on the lower side of the reader. The maximum tightening torque for the TNC sockets is 0.69 Nm (6.11 lbf in). Fig. 6: External antenna connection CAUTION: Exceeding the tightening torque will destroy the antenna connection.
IDENTIFICATION ID MAX.U500i 5 Terminals 5.2 Power Supply 5.2.1 Power Supply via Connector X2 The supply voltage of 12–24 V DC has to be connected to terminal X2. Fig. 7: Connector X2 pin assignment for power supply Pin Number at Abbreviation Description Connector X2...
IDENTIFICATION ID MAX.U500i 5 Terminals 5.2.2 Power Supply via PoE (Power over Ethernet) Optional the reader can be powered via the Ethernet interface on X1 with the use of a PoE „Power over Ethernet“ power supply according to IEEE802.3at*, Class4 (30/25,5Watt). The DC supply can be achieved via the free pins 4, 5 and 7, 8 (Midspan-Power).
IDENTIFICATION ID MAX.U500i 5 Terminals 5.3 Ethernet Interface on Connector X1 The reader has an integrated 10/100 base-T network port for an RJ-45. Connection is made on X1 and has an automatic “Crossover Detection” according to the 100BASE-T Standard. With structured cabling STP CAT5 cables should be used. This ensures a reliable operation at 10 Mbps or 100 Mbps.
IDENTIFICATION ID MAX.U500i 5 Terminals 5.4 Digital Outputs on Connector X4 There are 2 digital outputs available on terminal X4. The transistor connection, collector and emitter, of the optocoupler output is galvanically isolated from the reader electronic and routed to the outside at terminal X4 without internal additional circuitry.
IDENTIFICATION ID MAX.U500i 5 Terminals CAUTION: • The outputs are designed for an input voltage of 12-24 V DC and an input current of max. 20 mA. • Polarity reversal or overload of the outputs leads to their destruction! • The output is only intended for switching resistive loads.
IDENTIFICATION ID MAX.U500i 5 Terminals CAUTION: • The relay outputs are designed for max. 24 V DC / 2 A continuous load. • The maximum switching current must not exceed 1 A. • The relay outputs are intended for switching resistive loads only. In case an inductive load is connected, the relay contacts must be protected by an external protective circuit.
Page 20
IDENTIFICATION ID MAX.U500i 5 Terminals The external resistor Rext is optional. When wiring the reader, make sure that the input voltage is at least 10.5 V. CAUTION: • The inputs are designed for an input voltage of 12-24 V DC and an input current of max. 20 mA. Polarity reversal or overload of the inputs leads to their destruction! •...
IDENTIFICATION ID MAX.U500i 5 Terminals 5.7 USB Mini Interface on Connector X6 The reader is equipped with an integrated USB on-the-go interface. This can be used either to connect the reader to a host system or, by means of a special on-the-go adapter cable, for connection of a USB memory stick to the reader.
IDENTIFICATION ID MAX.U500i 5 Terminals In addition, the files ACTION.LOG and SERVICE.LOG with further information for service and maintenance for the devices will be generated and stored on the USB flash drive. The function of the CONFIG.INI is described in the following chapter. As vehicle access control reader the ID MAX.U500i stores the event table in the same subdirectory.
IDENTIFICATION ID MAX.U500i 5 Terminals 5.7.4 Copying the Configuration onto a Reader (Config-Cloning) In order to copy the configurations and access control data stored in a USB flash drive to a reader, the reader must be switched off before connecting the USB flash drive. After switching on the reader, the reader will search for a USB flash drive during the boot process and copy the configuration and access control data from the root directory to its memory.
IDENTIFICATION ID MAX.U500i 6 Operating and Display Elements 6 Operating and Display Elements Operating and Display Elements 6.1 Status LEDs The status LEDs are located under the push button T1 and the DIP switches S1. Reader status LEDs Res. Warning Description (yellow) (red)
The output power depends on the antenna gain. For calculating the reader output power the Excel file “Calc-RF-Power.xls” is available from FEIG ELECTRONIC GmbH. If a circular polarized antenna is used the antenna gain [dBic] can be reduced by 3 dB. If using a linear polarized antenna the max.
IDENTIFICATION ID MAX.U500i 7 Positioning of the Antenna 7 Positioning of the Antenna Positioning of the Antenna It is recommended to mount the antenna at the side of the roadway on a mast. The mounting height depends on the type of vehicle that should be detected. Vehicle Type Recommended Mounting Height cars only...
IDENTIFICATION ID MAX.U500i 7 Positioning of the Antenna Fig. 19: Typical vehicle access control application Fig. 20: Positioning of the antenna Page 27 of 36...
The transponders optionally available from FEIG ELECTRONIC GmbH are self-adhesive labels. To mount these transponders, simply remove the protective foil on the back and attach the transponder to the windshield.
IDENTIFICATION ID MAX.U500i 9 Technical Data 9 Technical Data Technical Data ECHANICAL Housing Plastic (ASA-PC) Aluminum Dimension (W x H x D) 290 mm x 290 mm x 100 mm (11.4“ x 11.4“ x 3.9“) Weight 2800 g Mounting VESA FDMI MIS-D 100 mm x 100 mm Protection Class IP 65 Colour...
Page 30
IDENTIFICATION ID MAX.U500i 9 Technical Data NVIRONMENTAL ONDITIONS Temperature Range -25 °C to 55 °C Operation • -25 °C to 85 °C Storage • Humidity 5 % to 95 % (non-condensing) Vibration EN 60068-2-6 10 Hz to 150 Hz: 0,075 mm / 1 g Shock EN 60068-2-27 Acceleration: 30 g...
10 Radio Approvals Radio Approvals 10.1 Europe (CE) Hereby FEIG ELECTRONIC GmbH declares that the radio equipment type ID MAX.U500i is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.feig.de/en/downloads-support/declarations-of-conformity.html...
United States / Canada. The system is intended for industrial and commercial use and requires professional installation. The device and the software required for commissioning and operation are only available from FEIG ELECTRONIC or its distributors. Installation, commissioning, configuration and operation require qualified knowledge of high-frequency and RFID technology due to its complexity.
IDENTIFICATION ID MAX.U500i 10 Radio Approvals 10.2.3 Label Information The following information must be placed at the outer side of the housing in which the reader is mounted. Contains FCC ID: PJMLRU500i Contains IC: 6633A-LRU500i 10.2.4 Antennas Approved in the USA (FCC) and Canada (IC) This radio transmitter (identify the device by certification number, or model number if Category II) has been approved by Industry Canada to operate with the antenna types listed below with maximum permission gain and required antenna impedance for each antenna type indicated.
IDENTIFICATION ID MAX.U500i Annex A: Radio Approvals Annex A: Accessories For the ID MAX.U500i following optional accessories are available: Order Number Article Description 24 V Power Supply Unit; Supply Cable available separately 2557.000.00 ID NET.24V-B for EU, GB and US (not included) 2558.000.00 ID CAB.NET.24V-B-EU Power Supply Unit Cable with continental Europe plug...
IDENTIFICATION ID MAX.U500i List of Tables List of Tables List of Tables Table 1: Connection Terminals ........................12 Table 2: Operating and Display Elements ....................... 12 Table 3: Pin assignment for power supply ....................... 14 Table 4: Validation procedures for external wiring of the power supply ............14 Table 5: Max.
IDENTIFICATION ID MAX.U500i List of Figures List of Figures List of Figures Fig. 1: Dimensional drawing – back view ......................8 Fig. 2: Dimensional drawing – side view ......................9 Fig. 3: Dimensional drawing – top view: opened housing ................10 Fig.