National Instruments PXIe-4610 Getting Started Manual

National Instruments PXIe-4610 Getting Started Manual

Hide thumbs Also See for PXIe-4610:

Advertisement

Quick Links

GETTING STARTED GUIDE
NI PXIe-4610
Power Amplifier
Français
This document explains how to install, configure, and set up the NI PXIe-4610 power amplifier.
NI-DAQmx 9.8 has added support for the NI PXIe-4610 device. To download the NI-DAQmx
driver, visit
ni.com/info
Electromagnetic Compatibility Guidelines
This product was tested and complies with the regulatory requirements and limits for
electromagnetic compatibility (EMC) as stated in the product specifications. These requirements
and limits are designed to provide reasonable protection against harmful interference when the
product is operated in its intended operational electromagnetic environment.
This product is intended for use in industrial locations. There is no guarantee that harmful
interference will not occur in a particular installation, when the product is connected to a test
object, or if the product is used in residential areas. To minimize the potential for the product to
cause interference to radio and television reception or to experience unacceptable performance
degradation, install and use this product in strict accordance with the instructions in the product
documentation.
Furthermore, any changes or modifications to the product not expressly approved by National
Instruments could void your authority to operate it under your local regulatory rules.
Caution
in the operational environment when test leads are attached or when connected to a
test object.
Caution
shielded cables and accessories.
Caution
must be no longer than 3 m (10 ft).
Caution
impair the protection the NI PXIe-4610 provides.
Deutsch
ni.com/manuals
and enter the Info Code
This product may become more sensitive to electromagnetic disturbances
To ensure the specified EMC performance, operate this product only with
To ensure the specified EMC performance, the length of all I/O cables
Using the NI PXIe-4610 in a manner not described in this document may
.
daqmx

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXIe-4610 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for National Instruments PXIe-4610

  • Page 1 Power Amplifier Français Deutsch ni.com/manuals This document explains how to install, configure, and set up the NI PXIe-4610 power amplifier. NI-DAQmx 9.8 has added support for the NI PXIe-4610 device. To download the NI-DAQmx driver, visit and enter the Info Code ni.com/info...
  • Page 2: Verify The Kit Contents

    Unpacking The NI PXIe-4610 module ships in an antistatic package to prevent electrostatic discharge from damaging device components. To prevent such damage when handling the device, ground yourself using a grounding strap or by holding a grounded object and complete the following steps: Touch the antistatic package to a metal part of the grounded object before removing the device from package.
  • Page 3: Install The Software

    Align the NI PXIe-4610 with the card guides on the top and bottom of the selected slots. NI PXIe-4610 Power Amplifier Getting Started Guide | © National Instruments | 3...
  • Page 4 10. Tighten the two front panel mounting screws to 0.31 N · m (2.7 lb · in.) on the top and bottom of the module front panel to secure the NI PXIe-4610 to the chassis. 11. Power on the chassis.
  • Page 5 Enable the NI PXIe-4610 Outputs The NI PXIe-4610 outputs are disabled by default. You must enable the outputs in MAX or programmatically. Complete the following steps to enable the outputs using MAX: Launch MAX. In the Configuration pane, expand Devices and Interfaces to see a list of installed devices.
  • Page 6 Figure 4 shows the connection of a floating signal source to an NI PXIe-4610 input. Figure 4. Connection for Floating Signal Source Signal Source – IN CHx – NI PXIe-4610 Connect a Load to the NI PXIe-4610 Output The NI PXIe-4610 outputs are differential and ground-referenced.
  • Page 7 Figure 6 shows the connection of a balanced, ground-referenced load to an NI PXIe-4610 output. Figure 6. Connection for Balanced Ground-Referenced Load Ω OUT CHx+ – OUT CHx – Ω NI PXIe-4610 You can connect an unbalanced, ground-referenced load, provided the impedance to ground can be driven by the NI PXIe-4610 outputs.
  • Page 8 Figure 8. NI PXIe-4610 Front Panel 8 | ni.com | NI PXIe-4610 Power Amplifier Getting Started Guide...
  • Page 9: Worldwide Support And Services

    512 795 8248. For telephone support outside the United States, visit the Worldwide Offices section of to access the branch office websites, which provide up-to-date ni.com/niglobal contact information, support phone numbers, email addresses, and current events. NI PXIe-4610 Power Amplifier Getting Started Guide | © National Instruments | 9...
  • Page 10 NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. © 2013 National Instruments. All rights reserved.

Table of Contents