1.

WIRE PREPARATION

Prior to crimping contacts, wire must be stripped to a length of .175" ± .025" [4.45 ± 0.64]. Wire
should have no insulation tearing or stretching and no conductor strands missing or damaged.
2.

CONTACT LOADING

Cycle handles to release ratchet and fully open crimp jaws. Insert contact in cavity recommended for
wire size. Adjust alignment and width of crimp wings if necessary to insure capture by crimp jaws.
WARNING:
Contacts may have sharp edges. Use finger protection to avoid cuts. Do not place fingers in
tool areas which may pinch during crimp cycle. Use safety glasses to avoid eye injury.
3.

HAND-CRIMP CYCLE

Close crimp tool until full-cycle ratchet control releases.
4.

CONTACT REMOVAL

After completing the crimp cycle, open jaws fully. Remove crimped contact.
5.

MAINTENANCE

To ensure correct functioning, maintenance must be performed on a regular basis. This includes:
Lubrication of moving parts.
Removal of debris from jaw areas.
Visual inspection for loose hardware, broken or missing parts.
6.

RECOMMENDED CAVITY FOR WIRE GAUGE AND INSULATION TYPES

Use this chart to insure best crimp results with Deutsch stamped and formed contacts
106*-14-01**, 106*-14-10**, 106*-16-01**, 106*-16-07**, and 106*-16-09**:
*
NOTE: when
**
Cavity
Revision Letter:
Title
Description
= 0, P/N is PIN contact;
= PLATING CODE; see individual contact Envelope Drawings for available types.
METRIC Wire Sizes
A
1.0 mm²
A
B
1.5-2.0 mm²
B
D
Engineering Order Number:
I N F O R M A T I O N
INDUSTRIAL
3850 Industrial Avenue
Revisions
1/08/08
2/21/08
12/20/10
*
when
= 2, P/N is SOCKET contact
AWG Insulation Types
16 TXL, 16 GXL, or 16 SXL
14 TXL, 14 GXL or 14 GXL
P20709
Hemet, CA 92545
Drawing Number
0425-037-0000
Date
Approved
R. Reed
D. Meyer
S. Beard
Page
1
of
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DTT-16-00 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Deutsch DTT-16-00

  • Page 1 Removal of debris from jaw areas. Visual inspection for loose hardware, broken or missing parts. RECOMMENDED CAVITY FOR WIRE GAUGE AND INSULATION TYPES Use this chart to insure best crimp results with Deutsch stamped and formed contacts 106*-14-01**, 106*-14-10**, 106*-16-01**, 106*-16-07**, and 106*-16-09**: NOTE: when = 0, P/N is PIN contact;...
  • Page 2 INDUSTRIAL • 3850 Industrial Avenue Hemet, CA 92545 Title Drawing Number INSTRUCTION GUIDE FOR DTT-16-00 0425-037-0000 CONDUCTOR  Cavity FARside  INSULATION Cavity NEARside   Wire Sizes Cavity Identification Revision Letter: Engineering Order Number: P20709 Page I N F O R M A T I O N...

This manual is also suitable for:

9-1606311-2Zpf000000000131994

Table of Contents