Four-wire electrical
connection:
Use this method for new installations,
mobile homes, recreational vehicles,
and whenever four-wire installation is
required.
7. Remove the ground-link screw from
the range frame. Save the ground-
link screw. Bend up the ground link
so that it does not contact the range.
ground link
8. Connect the green ground wire from
power supply cord to the range using
the ground-link screw. The ground
wire must be attached first and must
not contact any other terminal.
ground-
link screw
green
ground
wire
9. Connect the neutral (center wire)
wire to the center, silver-colored
terminal screw on the terminal block
using the brass nuts that are
attached to the terminal block cover.
silver-colored
terminal block screw
green
ground
wire
U.L. listed strain relief
and 40 amp range
power supply cord
10. Connect the other two wires to
the outer terminals on the
terminal block.
11. Do not loosen the factory installed
nuts already on the terminal.
Tighten nuts with 3/8" nut driver
for proper electrical connection.
12. Tighten the strain relief screws.
13. Replace the terminal block cover.
Three-wire electrical
connection:
silver-colored terminal
block screw
ground
link
line 1
ground-link
screw
Use this method only if local codes permit
connecting cabinet-ground conductor to
neutral wire of power supply cord.
7. Use the brass terminal nuts attached
to the terminal block cover to
connect the neutral wire (center
wire) to the silver-colored terminal
screw on the terminal block.
8. Connect the other two wires to
outer terminal screws on the
terminal block.
9. Do not loosen factory-installed nuts
already on the terminal. Tighten
nuts with 3/8" nut driver for proper
electrical connection.
10. Tighten the strain relief screws.
11. Reinstall the terminal block cover.
Direct wire method
NOTE: The bag containing three
aluminum terminal lugs must be used
when making a direct wire connection.
neutral wire
(center wire)
Disconnect power before servicing.
Use 8 gauge copper wire, or 6 gauge
aluminum wire.
Electrically ground range.
Failure to follow these instructions can
result in death, fire, or electrical shock.
This range may be connected directly to
the fuse disconnect or circuit breaker box;
or with a U.L.-listed, 40 amp range power
line 2
neutral
(center
wire)
U.L.-listed strain relief
and 40 amp range power
supply cord
WARNING
Electrical Shock Hazard
supply cable. Depending on your
electrical supply, make the required
three-wire or four-wire connection.
1. Disconnect power.
2. Remove the knockout for the power
supply cable.
3. Assemble a U.L.-listed conduit
connector in the opening.
U.L.-listed
conduit
connector
4. Strip the insulation back 1 inch from
the end of each wire.
1"
5. Allow enough slack in the wire to
easily attach the wiring to the terminal
block.
6. Use 3/8" nut driver and remove the
outside nuts on the terminal block
screws. Do not loosen the factory-
tightened nuts behind the outside nuts.
7. IMPORTANT: the aluminum lugs must
be assembled to the terminal posts
with the set screws facing out as
shown.
aluminum
lug
8. Attach three aluminum lugs to
terminal posts.
Use a 3/8" nut driver and tighten the
nuts securely. Nuts must be tightened
to 20 in/lbs of torque for proper
electrical connection.
9. Complete electrical connection
according to your type electrical
supply ("Four-wire electrical
connection" or "Three-wire electrical
connection. " )