LG-8TM ELITE
QUICK REFERENCE GUIDE
11
10
9
8
7
6
15
ELECTRODES
LEAD WIRES
For more information about your LG-8TM Elite unit, visit us at lgmedsupply.com or call 1-888-633-7360.
The purpose of this guide is to assist you in correctly operating your LG-8TM Elite unit. Do not use
this device for undiagnosed pain symptoms until consulting a physician. This guide is not intended to
replace or substitute the LG-8TM Elite Instruction Manual. PLEASE READ THE INSTRUCTION MANUAL
COMPLETELY BEFORE USING THIS DEVICE. Read, understand and practice the contraindications,
warnings, cautions and operating instructions found on pages 8 – 11 of your instruction manual. Always
follow the operating instructions prescribed by your healthcare provider.
1
Top
Front
DEFINITIONS
TENS
Transcutaneous Electrical
Nerve Stimulator
EMS
Electrical Muscle
Stimulation
IF
Interferential
RUSSIAN
of electro-stimulation
Back
Model: LG-8TM Elite 4 Channel
TENS/EMS/IF/Russia Unit
Supply Voltage: DC 9V/0.8A adaptor or 4XAA 1.5V batteries
Caution: Federal law (USA) restricts this
device to sale by or on the order of a physician
2
3
4
5
INDICATION FOR USE
The TENS and IF modes are often prescribed for:
• Symptomatic relief of chronic intractable pain
• Reduction of
• Post-traumatic acute pain and edema
• Post-surgical acute pain and edema
The EMS and RUSSIAN modes are often prescribed for:
• Relaxation of muscle spasms and edema reduction
• Prevention or retardation of disuse atrophy
• Increasing local blood circulation
• Muscle re-education
• Maintaining or increasing range of motion
• Immediate post-surgical stimulation of lower
Consulting a physician before using for undiagnosed pain.
Live Pain Free, Live Good Today!
Lead connector sockets - 4 channels
1
2
Liquid crystal display (LCD)
3
Panel cover
4
Mode control
5
6
Set control
7
Increment control for pulse rate,
14
pulse width and time indicators
8
Decrement control for pulse rate,
pulse width and time indicators
9
Intensity decrease control for
respective channels
Intensity increase control for
10
respective channels
12
11
Channels 1 – 4 LEDs
12
Belt clip
13
Battery case
14
Battery cover
13
15
AC adapter
LG-8TM Elite parts:
Side
WW3005 – lead wires
E1P2020TC2A – electrodes
leg muscles to prevent venous thrombosis
PAGE 1
Need help?
Do you have a question about the LG-8TM ELITE and is the answer not in the manual?
Questions and answers
I have the LG-8TM Elite and Channels 1 and 2 arbitrarily shut off after a few minutes of operation but Channels 3 and 4 continue to operate. Please advise.
Channels 1 and 2 on the LGMedSupply LG-8TM Elite may be shutting off while Channels 3 and 4 continue to operate due to the timer settings. The device has two adjustable timers: one for Channels 1 and 2 and another for Channels 3 and 4. If the timer for Channels 1 and 2 has expired while the timer for Channels 3 and 4 is still running, this could cause the issue. Adjusting the timer settings may resolve the problem.
This answer is automatically generated