Download Print this page

Denon AVR-2312CI Protocol Manual page 27

Avr control protocol
Hide thumbs Also See for AVR-2312CI:

Advertisement

EVENT(or RESPONSE) and PARAMETER list
EVENT
PARAMETER
PW
ON
STANDBY
MV
**
CV
FL **
FR **
C **
SW **
SL **
SR **
SBL **
SBR **
SB **
FHL **
FHR **
MU
ON
OFF
SI
CD
TUNER
DVD
BD
TV
SAT/CBL
DVR
GAME
The PARAMETER of MV, CV EVENT : Uses two or three ASCII characters. (see page6 J) section)
function
POWER ON/STANDBY change
MASTER VOLUME change , **:00 to 99 by ASCII
98 = 18dB(MAX)
80 = 0dB
00 = -80dB
995 = -80.5dB
99 = ---(MIN)
CHANNEL VOLUME change , **:00,38 to 62 by ASCII
62 = +12dB(MAX)
50 = 0dB
38 = -12dB(MIN)
00 = OFF (define ONLY SWch in DIRECT mode.)
(at SBch 2SP)
(at SBch 2SP)
(at SBch 1SP)
OUTPUT MUTE ON/OFF change
INPUT source change
- 27 -
example
PWON<CR>
PWSTANDBY<CR>
MV80<CR>
CVFL 50<CR>
CVFR 50<CR>
CVC 50<CR>
CVSW 50<CR>
CVSL 50<CR>
CVSR 50<CR>
CVSBL 50<CR>
CVSBR 50<CR>
CVSB 50<CR>
CVFHL 50<CR>
CVFHR 50<CR>
MUON<CR>
MUOFF<CR>
SICD<CR>
SITUNER<CR>
SIDVD<CR>
SIBD<CR>
SITV<CR>
SISAT/CBL<CR>
SIDVR<CR>
SIGAME<CR>

Advertisement