Advertisement

Quick Links

NOTICE:
This equipment has been tested and it complies with
This device complies with Part 15 of the FCC Rules.
Operation shall be subject to the following two
conditions:
(1) This device may not cause harmful interface, and
(2) This device must accept any interface received,
including interface that may cause undesirable
operation.
the limits for a Class a digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to
provide a reasonable protection against harmful
interference when the equipment is operated under a
commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in
a residential area is likely to cause harmful
interference in which case the user will be required to
correct the interference at his own expenses.
Note: All brands and trademarks shall belong to their
respective owner.
Note: Specification is subject to changes without
notice.
0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AR-3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for ArgoxScan AR-3000

  • Page 1 NOTICE: This equipment has been tested and it complies with This device complies with Part 15 of the FCC Rules. Operation shall be subject to the following two conditions: (1) This device may not cause harmful interface, and (2) This device must accept any interface received, including interface that may cause undesirable operation.
  • Page 2 Using the ArgoxScan AR-3000 The ArgoxScan can automatically scan barcode at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code.
  • Page 3: Table Of Contents

    CONTENTS Chapter 1 Introduction Introduction Default Setting ………………………………………. ArgoxScanAR-3000 specification ……………….. Programming the ArgoxScan…………………….. Chapter 2 Parameter Setting Interface Interface Selection ………………………………….. USB HID Keyboard……………………………….… RS-232 …………………………………………….…. Pin Assignments ……………………………………. System Control Scan mode...…………………………………………. Indication …………………………..………………… Code Option UPCA ……………………………………..………….
  • Page 4 Telepen ………………………………………………. Standard 2 of 5 ……………………………………… China Post …………………………………………… Italian pharmacode ………………………….……… GS1 Data Omniidirectiona (RSS-14)……..………. GS1 Databar Limited (RSS- Limited )………..…… GS1 Databar Expanded (RSS-Expanded) ……….. String Format String Setting / Transmission (Prefix/Suffix)………………………………………… String Setting / Transmission (Preamble/Postamble)……………………………… String Setting / Transmission (Insert Group Characters)…………………………..
  • Page 5 Introduction Installation RS-232 Disconnect power to the terminal/computer. Connect the appropriate interface cable and external power supply (DC adapter) to the scanner. Plug the serial connector into the serial port on the back of your computer/terminal. Tighten the two screws to secure the connector to the port.
  • Page 6: Default Setting

    Default setting For each barcode shown as below: Read Checksum Checksum Code Enable Code Type Verification Transmission Enable Enable 3000 UPC-A UPC-E EAN-13 EAN-8 * Code-39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code-128 V two digits Code-93 &...
  • Page 7: Interface

    AR-3000 Operational Light Source 623 nm Visible Red LED Optical System 2500 pixel CCD (Charge-coupled device) Depth of Scan Field 0-85 mm (code 39, PCS=90%, 20mils) Scanning Width 50 mm at 10mm Scan Speed 300 scans/sec Resolution 3mil Code39,PCS=90% Print Contrast 30% or more Pitch: ±60°...
  • Page 8 Current - Operating 200 mA@5 VDC Current - Standby 60 mA@5 VDC Physical and Environment Operating 0℃ to 50℃ (32℉ to 122℉) Temperature Storage -20℃ to 60℃ Temperature (-4℉ to 140℉) Humidity 5% to 90% relative humidity, non-condensing Light Level Up to 20000 Lux.
  • Page 9 Programming Scan Utility Programming Manual (Reading special barcode) method DOS command through RS-232, Windows configuration program Program upgrade Enabled built-in flash memory Programmable Code type selection, check digit characteristics selection, Decoding option Transmitted character delay, Message suffix, Good read beep tone and volume, Scanner trigger selection, interface type ,Data Editing...
  • Page 10 Programming the AR-3000 To program the AR-3000, you must scan a series of programming barcode in the correct order. On the last page of this manual, you will see a table of alphanumeric barcodes, which are used to program the various options presented.
  • Page 11 Program Barcode Program Option Bar Code Option Alphanumeric Entry Keyboard Wedge Interface RS-232 selection Wand emulation /RS-232 04* Auto detection Reserved Exit Option Barcode On the last page Exit Barcode Finish barcode...
  • Page 12: Interface Selection

    Interface Selection This decoder built-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial and the latest USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface.
  • Page 13: Usb Hid Keyboard

    USB HID Keyboard USB HID Keyboard Layout: The selecting of keyboard layout supports languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard”...
  • Page 14 Program Option Bar Code Option Alphanumeric Entry * Belgium Keyboard layout Danish France Germany Italian Portuguese Spanish Swedish Switzerland Latin American Japanese Disable * Enable Function key * Alphabetic key Numeric keypad Numeric key (Num lock state...
  • Page 15 only)Alt+Keypad Caps lock”ON” * Caps lock”OFF” Caps lock Caps lock for Mac Exit...
  • Page 16 RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 11 Xoff: Transmit Off (ASCII Code13 Flow control: None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol.
  • Page 17 communication of the scanner to wait for handshaking acknowledgment from the host computer. Program Option Bar Code Option Alphanumeric Entry None * RTS/CTS Flow control Xon/Xoff ACK/NAK 00-99 (msec) 00-99 * Inter-character delay 00-99 (10 msec) 00-99 * Block transmission delay 00-99 (100 msec) 00-99...
  • Page 18 Program Option Bar Code Option Alphanumeric Entry 600 BPS 1200 BPS Baud rate 2400 BPS 4800 BPS 9600 BPS * 19200 BPS 38400 BPS 57600BPS 115200BPS None * Parity Even 8 bits * 7 bits Data bit One bit * Two bits Stop bit Exit...
  • Page 19: Pin Assignments

    Pin Assignments RS-232 DB-9F Connector (To Host Side): Definition VCC (+5V)
  • Page 20 Scan Scanning mode: Good-read off-The trigger button must be pressed to activate scanning. The light source of the scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning.
  • Page 21 Program Option Bar Code Option Alphanumeric Entry Good-read off * Momentary Scanning mode Alternate Timeout off Continue (led on) Test only Continue (led off) 01-99 (second) 00-99 * Stand-by duration 01-99 (10 msec) 01-99 * Double read timeout 00-99 00-09 *...
  • Page 22 Scan Global min./max. code length: These are to define the min/ max readable code length of all symbologies. Code length less than min. code length or more than max. code length will not be read. In general, you can set the same value for both min.
  • Page 23 Program Option Bar Code Option Alphanumeric Entry 00-99 00-99 * Global min. code length 00-99 04-99 * Global max. code length * Disable Enable Inverted image scan Disable * Enable CTS trigger Exit...
  • Page 24 Scan Position indication: If the function is enabled, scan beam will flash as a pointer to help you aim at the bar code prior to scanning. The code will not be scanned until you press the trigger. Stand mode selection: Normally activated with continuous mode.
  • Page 25: Indication

    Indication Exit Power on alert: After power-on the scanner will generate an alert signal to indicate a successful self-test. LED indication: After each successful reading, the LED above the scanner will light up to indicate a good barcode reading. Beeper indication: After each successful reading, the scanner will beep to indicate a good barcode reading, and its Beep loudness, Beep tone freq.
  • Page 26 Program Option Bar Code Option Alphanumeric Entry Disable * Enable Power on alert Disable * Enable LED indication Disable * Enable Beeper indication 00-07 00-07 * Beep loudness 00-99 (100Hz) 00-99 * Beep tone freq. 00-99 (10 msec) 00-99 * Beep tone duration Exit...
  • Page 27: Upca

    UPCA Format Leading Data Digits Check Zero (11 Digits) Digit Read: Enable or disable the read function. Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero.
  • Page 28 Program Option Bar Code Option Alphanumeric Entry Disable * Enable Read Disable * Enable Check-sum transmission * Disable Enable Datamagic 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < A > Code ID setting Exit...
  • Page 29 UPCA Insertion group number selection: The scanner offers max. two insertion groups for one symbology. By setting one or two digits to indicate which insertion group you want to insert. You may refer to Character insertion. The function is to insert specific characters as a group into the transmitted data of selected symbologies.
  • Page 30 Program Option Bar Code Option Alphanumeric Entry 00-44 00-44 * Insert group number selection * None 2 digits Supplement digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 Exit...
  • Page 31 UPCA Truncation / Expansion: The leading “0” digits of UPCA data characters can be truncated when the function is enabled. Program Option Bar Code Option Alphanumeric Entry None * Truncate leading Truncation/ zero Expansion Expand to EAN13 00-99 00-99 * (verifications) Supplement Check Counter...
  • Page 32: Upce

    UPCE Read: Format Leading Data Digits (6 Check Zero Digits) Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Program Option Bar Code Option Alphanumeric...
  • Page 33 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < E > Code ID setting Exit...
  • Page 34 UPCE Insertion group number selection: Refer to Insertion group number selection of UPCA. Supplement digits: Format Supplement Digits Leading Data Digits Check 2 or 5 or Zero (6 Digits) Digit UCC/EAN Expansion: The expansion function is used only for UPCE and EAN-8 code reading.
  • Page 35 2, UCC/EAN 128 5, UCC/EAN 128 * None Truncate leading Truncation/Expansion zero Expand to EAN13 Expand to UPCA * Disable Enable Expansion * Disable Enable UPCE-1 00-99 00-99 * (verifications) Supplement Check Counter Exit...
  • Page 36 EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Truncate leading zero: Refer to Truncation / Expansion of UPCA. Program Option Bar Code Option Alphanumeric Entry...
  • Page 37 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending Exit...
  • Page 38 EAN-13 Code ID setting: Refer to page 30 Insertion group number selection of UPCA. Insertion group number selection: Refer to Insertion group selection of UPCA. Supplement digits: Format Supplement Digits Data Digits Check 2 or 5 or (12 Digits) Digits UCC / EAN ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two...
  • Page 39 * None 2 digits Supplement digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 * Disable Enable ISBN/ISSN conversion 00-99 00-99 * (verifications) Supplement Check Counter Exit...
  • Page 40 EAN-8 Read: Format Data Digits Check (7 Digits) Digits Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 30 Insertion group number selection of UPCA.
  • Page 41 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending Two characters 00-ffH, 00-ffH * 00-ffH ASCII < FF > Code ID setting code 00-44 00-44 * Insert group number selection Exit...
  • Page 42 EAN-8 Supplement digits: Format Supplement Digits Data Digits Check 2 or 5 or (7 Digits) Digits UCC/EAN 128 Truncation / Expansion: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE. Program Option Bar Code Option Alphanumeric Entry *...
  • Page 43 * Disable Enable Expansion 00-99 00-99 * (verifications) Supplement Check Counter Exit...
  • Page 44 Code 39 Read: Format Start Data Digits Checksum “★” ( Variable) (Optional) “★” Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check-sum transmission: By setting Enable, checksum will be transmitted.
  • Page 45 * Disable/Disable Disable/Enable Check-sum transmit Enable /Enable /verify * Disable Enable Datamagic 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-20 00-20 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH code * < >...
  • Page 46: Code 39

    Code 39 Insertion group number selection: Refer to page 30 Insertion group number selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is data with a total of 128 characters to represent Full ASCII code. It is combined with one of the digits +, %, $ and/ with one of the alpha digits (A to Z).
  • Page 47 * Standard Full ASCII Format * Disable Enable Append * Disable Enable Start/end transmission Exit...
  • Page 48: Interleaved 2 Of 5

    Interleaved 2 of 5 Read: Format Data Digits Checksum (Variable) (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 49 * Disable Enable Datamagic 00-64 00-64 * Max. code leading 00-64 00-64 * Min. code leading 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < i > Code ID setting 00-44 00-44 * Insert group number selection Exit...
  • Page 50: Industrial 2 Of 5

    Industrial 2 of 5 Read: Format Data Digits Checksum (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 30 Insertion group number selection of UPCA.
  • Page 51 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < i > Code ID setting 00-44 00-44 * Insert group number selection Exit...
  • Page 52: Matrix 2 Of 5 Eur

    Matrix 2 of 5 Eur Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min.
  • Page 53: Code-93

    * Disable Enable Datamagic 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < B > Code ID setting 00-44 00- 44 *...
  • Page 54 Codabar Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 55 * Disable Enable Datamagic 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII code 00-ffH * < % > Code ID setting Exit...
  • Page 56 Codabar Insertion group number selection: Refer to Insertion group number selection of UPCA. Start/End type: The Codabar has four pairs of Start/End patterns; you may select one pair to match your application. Start/End Transmission: Refer to Start/End Transmission of Code 39. Program Option Bar Code Option...
  • Page 57 Code-128 Read: Format Data Digits Checksum (Variable) (Optional) Checksum Verification: The checksum is made as the sum module 103 of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Program Option Bar Code Option Alphanumeric Entry Disable *...
  • Page 58 Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to Insertion group number selection of UPCA. Format: The Code-128 can be translated to UCC/EAN-128 format if it starts with a FNC1 character.
  • Page 59 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < # > Code ID setting 00-44 00-44 * Insert group number selection * Standard UCC/EAN-128 Format Exit...
  • Page 60: Code-11

    Code-128 Append: When this function is enabled, it won't show the data immediately if scanner reads a barcode that includes FNC2 code. It will show all data until it read the barcode, which doesn't have FNC2 code. UCC/ EAN 128 ID setting: To set the code ID for UCC/EAN-128 output format.
  • Page 61 Code-93 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Program Option Bar Code Option Alphanumeric Entry...
  • Page 62 Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to Insertion group number selection of UPCA. Program Option Bar Code Option...
  • Page 63 00-ffH ASCII 00-ffH * code < & > Code ID setting 00-44 00-44 * Insert group number selection Exit...
  • Page 64 Code-11 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min.
  • Page 65: Msi/Plessey

    * Disable Enable Datamagic 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII code 00-ffH * < O > Code ID setting 00-44 00-44 * Insert group number selection Exit...
  • Page 66 Read: Format Data Digits Checksum1 Checksum2 (Variable) (Optional) (Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented using 3 kinds of methods Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits.
  • Page 67 * N/disable N/MOD 10 Checksum N/Mod 10,10 Transmit/Verifiy N/mod 11,10 Y/ Mod10 Y/ Mod 10,10 Y/ Mod 11/10 * Disable Enable Datamagic 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 *...
  • Page 68 Code ID setting 00-44 00-44 * Insert group number selection Exit...
  • Page 69: Uk/Plessey

    UK/plessey Read: Format Data Digits Checksum1+2 (Variable) (Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
  • Page 70 * Disable Enable Datamagic 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < @ > Code ID setting 00-44 00-44 * Insert group number selection Exit...
  • Page 71: Telepen

    Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 72 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < S > Code ID setting 00-44 00-44 * Insert group number selection Numeric only *...
  • Page 73: Standard 2 Of 5

    Standard 2 of 5 Read: Format Data Digits Checksum1 (Variable) (Optional) Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39.
  • Page 74 * Disable Enable Datamagic 00-64 00-64 * Max. code length 00-64 *JAC* 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < i > Code ID setting 00-44 00-44 *...
  • Page 75: China Post

    China Post Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to Insertion group number selection of UPCA.
  • Page 76 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < t > Code ID setting 00-44 00-44 * Insert group number selection Exit...
  • Page 77: Italian Pharmacode

    Italian Pharmacode (Code 32) Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to Insertion group number selection of UPCA.
  • Page 78 00-64 00-64 * Max. code length 00-64 00-64 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 01-ffH * code < p > Code ID setting 00-44 00-44 * Insert group number selection *...
  • Page 79 GS1 Databar Omnidirectional Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to Transmission, Code ID transmission must be set as AIM ID enable.
  • Page 80 * Disable Enable Datamagic 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < R4 > Code ID setting 00-44 00-44 * Insert group number selection * Disable Enable UCC/EAN128 emulation Exit...
  • Page 81: Gs1 Databar Limited (Rss- Limited )

    GS1 Databar Limited Read: Format Data Digits Checksum1 (Variable) (Optional) Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to Insertion group number selection of UPCA. UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation of RSS-14.
  • Page 82 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < RL > Code ID setting 00-44 00-44 * Insert group number selection * Disable Enable UCC/EAN128 emulation Exit...
  • Page 83: Gs1 Databar Expanded (Rss-Expanded)

    GS1 Databar Expanded Read: Format Data Digits Checksum1 (Variable) (Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to Insertion group number selection of UPCA.
  • Page 84 00-99 00-99 * Min. code length 0-15 00-15 * Truncate leading 0-15 00-15 * Truncate ending 00-ffH ASCII 00-ffH * code < RX > Code ID setting 00-44 00-44 * Insert group number selection * Disable Enable UCC/EAN128 emulation Exit...
  • Page 85: String Setting / Transmission

    String setting / Transmission (Prefix / Suffix) Prefix / Suffix characters setting: Characters defined as prefix or suffix characters will be transmitted immediately with the scanned data for all symbologies. Up to 12 ASCII characters can be defined as Prefix or Suffix. Format of barcode data transmission: Code Barcode...
  • Page 86 Program Option Bar Code Option Alphanumeric Entry * None 1-22 characters 00-ffH ASCII Prefix characters code setting * None 1-22 characters 00-ffH ASCII Suffix characters code setting Exit...
  • Page 87: String Setting / Transmission (Preamble/Postamble)

    String setting / Transmission (Preamble/Postamble) Preamble/ Postamble characters: Preamble or Postamble characters will be appended to the data automatically for all symbologies. However, the transmission will not activate unless Preamble / Postamble transmission is enabled. Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted.
  • Page 88 Program Option Bar Code Option Alphanumeric Entry * None 1-12characters 00-ffH ASCII Preamble characters code setting * None 1-12haracters 00-ffH ASCII Postamble code characters setting Disable * Enable Preamble transmission * Disable Enable Postamble transmission Exit...
  • Page 89: String Setting / Transmission (Insert Group Characters)

    String setting / Transmission (Insert Group Characters) Insert G1/G2/G3/G4 character setting: The scanner supports inserting two groups with each group 22 characters into transmitted data of selected symbologies. The two groups can be inserted into scanned data of the selected symbologies or positioned at leading / ending of data.
  • Page 90 5) Repeat the same procedure in Insert G2 characters setting. 6) Scan Exit barcode. Insert data group 1-4 position. Please refer to Chapter- Transmission, page 65 and to the specific barcode that you want to use. Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbols.
  • Page 91 String setting / Transmission (Insert Group Characters) Program * None 1-12 characters 00-ffH ASCII Insert G3 characters code setting * None 1-12 characters 00-ffH ASCII Insert G4 characters code setting * None Insert G5 characters 1-12 characters 00-ffH ASCII setting code *...
  • Page 92 setting code None 00* Insert G10 1-12 characters 00-ffH ASCII characters setting code 00-63 00-63 * (00: no insertion) Insert data group 1 position 00-63 00-63 * (00: no insertion) Insert data group 2 position 00-63 00-63 * (00: no insertion) Insert data group 3 position 00-63...
  • Page 93: String Setting / Transmission (Others)

    String setting / Transmission (Others) Code ID position: Upon using, the transmitting position of Code ID can be selected to place Before Code Data or After Code Data when it is transmitted. Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM Code length transmission: A number of data digits can be transmitted before the code data when Enable is selected.
  • Page 94 * Before code data After code data Code ID position * Disable Proprietary ID Code ID AIM ID transmission * Disable Enable Code length transmission * Disable Enable Code name transmission * Disable Upper case Case conversion Lower case *For barcode data only Exit...
  • Page 95: Datamagic

    Datamagic DataMagic has eight functions. The Scanner allows a maximum of 10 Rules. Functions are described below. Important Data Magic default is disabled. To enable Data Magic function, go to Code Option and find Data Magic column to enable it. Each Rule has the following structure: Leading+RuleNo.+Action+Parameter1+ Parameter2 Leading:...
  • Page 96 RULE7 RULE8 RULE9 RULE10 Action: 0~9, 0->Insert Front, 1->Cut Front, 2->Cut Back, 3-> Replace, 4->Keep Front,...
  • Page 97 5->Keep Back, 6-> Find & Cut Front, 7-> Find & Cut Back. 8->Insert Back, 9->Erase Parameter1: Each function is indicated differently. Parameter2: Each function is indicated differently. To erase all of the DataMagic setting values, just scan the barcode below.
  • Page 98 To display all of the current related setting results, scan: Program (DataMagic settings) (Inserted Group settings)
  • Page 99 Example Data Original Barcode Data: ARGOX89121121 Insert Group 1: ARGOX Insert Group 2: argox Insert Group 3: GOX Insert Group 4: Tel: Insert Front: In the original data, insert a group at a specified position from the front. Para1 specifies the insert position (starting from position 0).
  • Page 100 Programming for the example above: Program RULE1 Insert Front Para1 (Two digits) Para2 (Two digits) Finish Exit...
  • Page 101: Test Chart

    Test Chart (Bar code samples marked with symbol “*” are enabled initially.) CODABAR CODE-11 CODE-128 * CODE-39 * CODE-93 EAN-13 *...
  • Page 102 STANDRAD-25 EAN-8 * INDUSTRIAL-25 UPCE * INTERLEAVED-25 *...
  • Page 103 MATRIX 25 MSI/PLESSEY UPCA * UK/PLESSEY GS1 dat bar...
  • Page 104: Ascii Code Table

    ASCII Code Table Note: For keyboard wedge only. Null Down Left Right PgUp PgDn Home Enter Insert Ctrl+ Delete Alt+ “ & ‘ ★ ﹛ , < \ ︱ ﹜ > 〜...
  • Page 105: Parameter Setting List

    Program Barcode standard parameter setting list If you wish to display the current configuration of your AR-3000, scanner over the host terminal/computer, scan the Barcode standard parameter setting list bar code. Unique parameter list If you wish to display the unique parameter setting list, scan...
  • Page 106 Query Datamagic Setting Formatted: Indent: Left 0.75 ch, First line: 0.5 ch Program Firmware version list If you wish to display the Datamagic setting , scan the “Query Datamagic Setting ” barcode. Exit Query present scanner firmware version Program Firmware version list If you wish to display the firmware version, scan the “Firmware version list”...
  • Page 107 Reset scanner to factory default settings Program WARNING: Default value initialization If you wish to return the AR-3000 to all the factory default settings, scan the Default value initialization bar code.
  • Page 108 Finish...

Table of Contents