Installation Instructions; -SDO Separate Drain Overflow
NOTE: THESE INSTALLATION
INSTRUCTIONS ARE USED FOR ALL
WHITEHALL STATIONARY ALL MODELS
WITH -SDO SEPARATE DRAIN & OVERFLOW
ASSEMBLIES
REFERENCE DRAWINGS
ASSEMBLIES
MOTOR/TURBINE
RAISING & LOWERING - "E" & "P"
RAISING & LOWERING
DRAIN OVERFLOW - "E"
RAIN OVERFLOW - "H" & "S"
DRAIN OVERFLOW - "P"
THERMOMETER
ASSEMBLY PROCEDURE:
A-
ROUGH-IN FOR 2" OD DRAIN LINE 1 AND WATER INLET VALVE.
(SEE DETAIL A) NOTE: FOR INFORMATION ON OPTIONAL
THERMOSTATIC MIXING VALVE CONTACT FACTORY.
B-
LOCATE TANK AND SECURE WITH "L" BRACKETS 2 , WITH
INSTALLER PROVIDED FLOOR ANCHORS AND ANCHORING
HARDWARE. MAKE WASTE CONNECTIONS 1 .
C-
INSTALL MOTOR/TURBINE ASSEMBLY 3 INTO RAISING AND
LOWERING ASSEMBLY 4 BY LOOSENING HANDLE 5 , SLIDING
MOTOR SUPPORT ROD 6 INTO RAISING AND LOWERING
ASSEMBLY 4 AND TIGHTENING HANDLE 5 .
D-
INSTALL THERMOMETER 7 THRU UPPER BRACKET 8 AND
INTO LOWER BRACKET 9 , TIGHTEN SCREW 10 .
E-
TURN THE PRESSURE CONTROL VALVE HANDLE 11 FULLY
CLOCKWISE, THEN FULLY COUNTERCLOCKWISE TO
COMPLETELY LUBRICATE THE PLUNGER ASSEMBLY.
F-
PROVIDE ELECTRICAL SERVICE AND PROPERLY INSTALLED,
GROUND FAULT CIRCUIT INTERRUPTER (GFCI) FOR MOTOR
SPECIFIED. MOTOR SPECIFICATIONS AVAILABLE ARE EITHER
120V AC / 60 HZ ON 15A CIRCUIT OR 240 V AC / 50 HZ ON 10A
WARNING
WARNING
Turbine assembly is provided with a 3-way plug. The
third prong functions as a built-in ground and must be
plugged into a matching grounded GFCI receptacle to
properly ground the product.
WHITEHALL MANUFACTURING • P.O. Box 3527 • City of Industry, CA 91744-0527 U.S.A.
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
Installation Instructions; -SDO Separate Drain Overflow
3
4 "
PAGE NUMBER
9/10
11
12
15
14
17
23
8
10
9
1"
2
C L
3 1 2 "
DETAIL "A"
(TOP VIEW)
7
OPERATION PROCEDURE:
A-
FILL TUB AS DESIRED USING THERMOSTATIC MIXING VALVE.
WATER LEVEL SHOULD BE A MAXIMUM OF 4" BELOW THE RIM
AND A MINIMUM OF 6" ABOVE BOTTOM OF PUMP 12 .
B-
TURN THE PRESSURE CONTROL VALVE HANDLE 11 FULLY
CLOCKWISE, THIS PROVIDES MAX PRESSURE AND AGITATION.
C-
TURN ON THE SWITCH 13 .
D-
ADJUST RAISING AND LOWERING ASSEMBLY 4 BY SLOWLY
PUSHING DOWN ON TOP OF THE MOTOR SUPPORT CASTING 14
UNTIL THE PUMP 12 IS AT THE DESIRED LOCATION. TIGHTEN
HANDLE 5 . INTERNAL BUSHING MAY NEED ADJUSTMENT.
E-
ADJUST PRESSURE CONTROL VALVE 11 TO DELIVER DESIRED
LEVEL OF AGITATION AND PRESSURE.
DRAINING PROCEDURE:
A-
TURN OFF SWITCH 13 .
B-
TURN HANDLE 15 CLOCKWISE TO OPEN DRAIN VALVE 16 .
13