Page 1
INSTRUCTIONS FOR OPERATION AND CARE OF (Stationary Whirlpool) E-27-S S-90-S Member of 6900-194-000 Revised: February 2016...
Page 2
European Union CE Mark The presence of the CE Mark on Whitehall equipment means that it has been designed, tested and certified as complying with all applicable European Union regulations and recommendations. Waste Electrical and Electronic Equipment (WEEE) This s ymbol on the product or on its packaging indicates that this product must not be disposed of with regular waste.
INSPECTING THE WHIRLPOOL This Whitehall product has been carefully packaged at the Inspection Checklist factory to minimize the possibility of damage during shipping.
Installing the Whirlpool, page 4. A rough-in drawing is available to assist the installer. Contact Whitehall Customer Service, bottom of page, for additional installation not covered in this manual. Ÿ Confirm that the whirlpool operates properly. See Inspecting the Whirlpool , page 2.
(1327) ELECTRICAL REQUIREMENTS: 8 AMPS, 115 VOLTS. 2" COMBINATION DRAIN AND OVERFLOW ASSEMBLY AT WALL PROVIDE ONE 3 POLE RECEPTACLE HOSPITAL FURNISHED BY WHITEHALL GRADE WITH GROUND FAULT INTERRUPT FOR TURBINE OVER RIM INLET ASSEMBLY HOT & COLD WATER INLET THERMOSTATIC MIXING VALVES ARE OPTIONAL 2"...
Installation Instructions 4 " NOTE: THESE INSTALLATION 1" INSTRUCTIONS ARE USED FOR ALL WHITEHALL OR DAKON STATIONARY ALL MODELS. 5" REFERENCE DRAWINGS ASSEMBLIES PAGE NUMBER 2 1 4 " MOTOR/TURBINE RAISING/LOWERING/SM DETAIL "A" RAISING/LOWERING (TOP VIEW) DRAIN OVERFLOW E DRAIN OVERFLOW H/S...
Installation Instructions; -SDO Separate Drain Overflow Installation Instructions; -SDO Separate Drain Overflow 4 " 1" NOTE: THESE INSTALLATION INSTRUCTIONS ARE USED FOR ALL WHITEHALL OR DAKON ALL STATIONARY -SDO MODELS. REFERENCE DRAWINGS ASSEMBLIES PAGE NUMBER 7 7 8 " MOTOR/TURBINE...
Installation Instructions; Slant Back REFERENCE DRAWINGS ASSEMBLIES PAGE NUMBER MOTOR/TURBINE RAISING/LOWERING DRAIN OVERFLOW THERMOMETER 12 1 8 " 6 7 8 " 1 1 4 " TYP. 17" TYP. DETAIL "A" (TOP VIEW) ASSEMBLY PROCEDURE: ROUGH-IN FOR 2" OD DRAIN LINE 1 AND WATER INLET VALVE. (SEE DETAIL A) NOTE: FOR INFORMATION ON OPTIONAL THERMOSTATIC MIXING VALVE CONTACT FACTORY.
Stationary Motor/Turbine Assembly THESE REPAIR PARTS ARE USED FOR THE FOLLOWING MODEL NUMBERS ONLY: 14 15 WHITEHALL MODEL DAKON WHITEHALL MODEL DAKON NUMBERS MODEL NUMBERS NUMBERS MODEL NUMBERS E-15-M-SDP DD-2516 L-75-M-SDP E-15-S DF-2516 L-75-S E-22-M-SDP DD-2818 L-90-M-SDP DD-6018 E-22-S DF-2818...
Stationary “H” Series Parts Diagram THESE REPAIR PARTS ARE USED FOR THE FOLLOWING MODEL NUMBERS ONLY: WHITEHALL MODEL DAKON NUMBERS MODEL NUMBERS H-60-M-SDP DD-3628 H-60-S DF-3628 H-75-M-SDP H-75-S H-90-M-SDP H-90-S H-105-M-SDP DD-4828 H-105-S DF-4828 * NOTE: SEE ADDITIONAL DRAWING FOR DETAIL OF ITEMS NOT SHOWN.
Stationary “L” Series Parts Diagram THESE REPAIR PARTS ARE USED FOR THE FOLLOWING MODEL NUMBERS ONLY: WHITEHALL MODEL DAKON NUMBERS MODEL NUMBERS L-75-M-SDP L-75-S L-90-M-SDP DD-6018 L-90-S DF-6018 L-105-M-SDP DD-6618 L-105-S DF-6618 * NOTE: SEE ADDITIONAL DRAWING FOR DETAIL OF ITEMS NOT SHOWN.
Stationary “P” Series Parts Diagram THESE REPAIR PARTS ARE USED FOR THE FOLLOWING MODEL NUMBERS ONLY: WHITEHALL MODEL DAKON NUMBERS MODEL NUMBERS P-10-M-SDP P-10-S P-15-M-SDP DD-2516 P-15-S DF-2516 P-22-M-SDP DD-2818 P-22-S DF-2818 NOTE: SEE ADDITIONAL DRAWING FOR DETAIL OF ITEMS NOT SHOWN.
Stationary “S” Series Parts Diagram THESE REPAIR PARTS ARE USED FOR THE FOLLOWING MODEL NUMBERS ONLY: WHITEHALL MODEL DAKON NUMBERS MODEL NUMBERS S-85-M-SDP S-85-S DFT-4825 S-90-M-SDP S-90-S S-110-M-SDP S-110-S DFT-5625 NOTE: SEE ADDITIONAL DRAWING FOR DETAIL OF ITEMS NOT SHOWN.
Motor Raising & Lowering Assembly (Small) THESE REPAIR PARTS ARE USED FOR THE FOLLOWING MODEL NUMBERS ONLY: WHITEHALL DAKON MODEL MODEL NUMBERS NUMBERS E-15-S DF-2516 E-22-MU E-22-S DF-2818 E-22-SP P-10-S P-15-S DF-2516 P-22-S DF-2818 R & L ASSY P-10-S R & L ASSY P/E-15-S R &...
R & L ASSY L-75/90/105-S ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION 6530-220-001 1" DIA. R & L ASSY - E-27-S 6503-075-000 1-1/8" x 34" SPRING - H-60/75/90/105-S 6530-235-001 1" DIA. R & L ASSY - E-45/S-85/90/110-S 6503-060-000 1-3/8" x 23-1/2" SPRING - L-75/90/105-S 6530-245-001 1"...
Motor Raising & Lowering Assembly (Slant Back) SCALED x 1-1/2 ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION 6530-260-001 R & L ASSEMBLY 0116-104-000 1/4"-20 x 1/2" PHILLIPS ROUND HEAD SCREW 6502-401-000 1/4"-20 x 5/16 SET SCREW 6530-310-199 END CAP 6530-411-199 LOCKING HUB 6530-520-000...
Separate Drain / Overflow Assembly - P-10, P/E-15/22 1B 1C ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION 6531-200-001 SEPARATE DRAIN OVERFLOW - P-10-S 6531-330-000 STRAINER ASSY - FOR -SDO & BURN TANKS 6531-205-001 SEPARATE DRAIN OVERFLOW - P/E-15-S 6531-331-199 LOCK RING 6531-210-001 SEPARATE DRAIN OVERFLOW - P/E-22-S...
Separate Drain / Overflow Assembly - H60/70/90, S85/90 1D 1E 5C 5D ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION 6531-230-001 SEPARATE DRAIN OVERFLOW - H-60-S 6509-605-199 DRAIN ROD - H-60/75/90-S 6531-235-001 SEPARATE DRAIN OVERFLOW - H-75-S 6509-604-199 DRAIN ROD - S-85/90-S 6531-250-001 SEPARATE DRAIN OVERFLOW - H-90-S 6531-330-000...
Thermometer NOTE: THE THERMOMETER GAUGES TEMPERATURES FROM 40° TO 140° F. DO NOT ALLOW TEMPERATURES TO EXCEED 140° TO AVOID DAMAGING THE THERMOMETER. TO RECALIBRATE: IMMERSE THE STEM A MINIMUM OF 4” INTO THE WATER TURN ON THE TURBINE ASSEMBLY AND ANOTHER ACCURATE TEMPERATURE GAUGE TO COMPARE AND USE THE EXTERNAL ADJUSTMENT SCREW PROVIDED ON THE THERMOMETER CASING AS INDICATED a .
8. Fill the bucket with water and run turbine for five seconds to rinse impeller cavity. *Whitehall recommends the use of Hydrochlor® Whirlpool Antiseptic with all patient treatments. This simplifies cleaning of equipment by eliminating need for repeated rinsing and scrubbing.
To remove rust stains: THINGS TO AVOID Wipe surfaces with CRES (available through Whitehall) or Ÿ Harsh polishing cleanser (Comet, Bon Ami, etc.) equivalent cleaner. Use recommended solutions. Apply Ÿ...
MSDS, Material Safety Data Sheets. You can purchase a recommended disinfectant from Whitehall Customer Motor does not start when switch is turned on: Service (Back of Manual) or your Whitehall distributor. Ÿ Check your power source. Have a qualified technician check switch.
Motor Information MOTOR DISASSEMBLY Motor Cover Waterproof Toggle Switch Cover Switch Motor Wire Connector Assemblies Motor Base Power Cord Capacitor Assembly Condenser Cover SWITCH WIRING (115V) SWITCH WIRING (230V) SWITCH SWITCH POWER INLET POWER INLET MOTOR MOTOR YEL/GRN YEL/GRN...
Page 34
Whitehall Manufacturing Company warrants that its products are free from defects in material or workmanship under normal use and service for a period of one year from date of shipment. Whitehall's liability under this warranty shall be discharged solely by replacement or repair of defective material, provided Whitehall is notified in writing within one year from date of shipment, F.O.B.