Page 1
Via Malintoppi, 32 63025 FERMO (AP) ITALY Tel/Fax: (0039) 0734 605080 Web: www.elcasnc.com Control board for swing gates. REV. 3 E-Mail: elcasnc@tin.it FOLLOW THIS INSTRUCTIONS CAREFULLY This manual contains important instructions for installation and use of this control board mod. ECLIPSE2.
FOR SAFETY REASON A SAFETY DEVICE MUST BE USE WHEN USING THIS REMOTE CONTROL !!! TERMINALS CONNECTIONS : Antenna, terminal n°2 = RF 15-14 “Start/Stop” push button (n.o. contact) Input from intercom 12Vac see <T> 16-14 SS2 push button motor n 2 command Closing limit switch (n.c.
Page 3
>>>> AT ANY TIME YOU CAN FETCH THE BASIC PROGRAM BY THE RESET FUNCTION <<<< RESET • Turn OFF the power. • Set the dips A7, A8, A10.in ON position • Turn ON the power, the led OK goes ON ,then start to flashing, the reset is finish •...
Page 4
Code Stop A10. set the DIP A9 in ON position and open the contact 60 cm 14 13 between terminals n 13-14. A11. send a code with transmitter as step A2 A12. set the dip A9 in OFF position and close the contact 1 Flash on terminals n 13-14.
Page 5
B5. After 2 seconds that the gate is completely opened send a third command for stopping. Motor2 After 2 sec give the 3th impulse to stop the motor B6. repeat steps B3, B4, B5 for closing time programming. B7. set the DIP A8 in OFF position ,the led OK goes off.
Page 6
B14. set the DIP A7 in OFF position the led OK goes off. NOTE : you can make several movement in opening and in closing, only the last will be memorized !!!!. <C>MOTORS TIME PROGRAMMING WITHOUT SLOWING DOWN. -- set and leave the DIP B4 in ON position. -- set the trimmer Forza to +”...
- time Motor n°1 - C7. place the gate n 2 open and the gate n 1 Motor2 Motor1 to close position. Turn OFF the power. Gate to Turn ON the power program C8. set the DIP A7 in ON position, the led OK goes on.
Page 8
<F> CHANGE DELAY CLOSING TIME F1. set the DIP B3 in ON. position F2. set the DIP A6 in ON position, the led OK goes on, leaving for the time required, then set it in OFF position. Fixed F3. set the DIP B3.in OFF position NOTE: if the dip B3 is leave in ON position the time delay is = 0 second that mean booth motor start in closing at the same...
Page 9
No step by step logic for pneumatic bar If on terminals n 10-11 you connect a pneumatic bar, when the bar is pressed the gate reverse the movement for 1,5 second then stop. <I> RADIO CODE ERASING - erasing all code. I1.
Page 10
<N> NO ELECTRIC-LOCK COMMAND DIP B1 -- set and leave the DIP B1 in ON position <O> NO DELAY IN CLOSING DIP B3 set and leave the DIP B3 in ON position, in this way booth gates close at the same time <P>...
ELCA devices and accessories are guaranteed for a period of 24 months after production, whose date is printed on each items. ELCA will replace or repair its devices, provided that they are returned to our plant. In order to check the actual functioning of the returned pieces, they will remain the property of manufacturer.
Need help?
Do you have a question about the Eclipce 2 and is the answer not in the manual?