Program Values - Bosch GWH 2700 ES LP User Manual

Bosch appliances water heater user manual
Hide thumbs Also See for GWH 2700 ES LP:
Table of Contents

Advertisement

Maintenance and service
6.5

Program values

This section describes details on programming the
appliance. For most applications the factory default
values will robust and stable operation. Only adjust the
factory settings if the installation requires changes as
indicated in the appropriate section of this manual.
Program
Description
P1
Maximum Power
P2
Minimum Power
P3
Remote Con-
trols installed
P4
Access to Diag-
nostic Mode
P5
Cascade Mode
P6
Temperature
Unit
P7
Appliance Type
P8
Back light
P9
Fan Purge
Table 18 Program values, factory default settings and ranges.
* Incorrect setting causes errors.
36
Factory Default
MIN
NG: 48, LP: 46
21
7
7
_0
_0
E
0d
NO
NO
°F
°F
NO
Cd
dE
dE
Refer to chapter 6.6 Control board diagnostics (page
37) regarding how to access these P-modes.
Caution:
Misadjusted
values
can
malfunction, errors, and service
calls.
MAX
Comment
NG: 50, LP: 49
see chapter 3.12, page 27.
note: reducing P1 values below
maximum will reduce maximum
power of the appliance.
20
see chapter 3.3.6, page 17
6
see chapter 5.5, page 31
10f
see chapter 6.6, page 37
CC
contact Bosch for details
°C
NO
Condensing / Non-condensing*
ON
dE turns back light off after 60
seconds
pushed, ON turns backlight on
permanently
runs secondary and primary fan
when
depressing the "P" - button
program
lead
to
appliance
from
last
button
P9
is
selected
6 720 608 542
by

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwh 2700 es ngGwh 2400 es ngGwh 2400 es l