Applications; Automatically Recording Harmonics - BRUEL & KJAER 1022 Instructions And Applications

Beat frequency oscillator
Table of Contents

Advertisement

2. Press pushbutton marked
SINGLE CHART and
hold in.
(Paper
will
move and the reference voltage
commences
to record). Release push-
button when paper has moved to about the
"200" c/s
line.
3.
Units
are
correctly synchronized
when
switching
from the 80
ci
s
to the 100
c/
s
filter takes place
on
the 90
c/
s
line.
4. As a
means to
see
how far the paper has to be
shifted,
it is re-
commended
to draw
a
line, by means
of
the
"100
mV
Ref." button
on
the front plate
of
the Recorder,
at
the
point
where the paper has
stopped.
By using this line
as a
reference the paper
can be shifted
the
appro·
p riate distance to
give correct synchronization.
5.
To
check
the
synchronization,
run the recording until
the pen
is
stopped on
for
example
the 2ooo
c/
f>
line. When
correctly syn-
chronized,
the
switching
of the
800 c/s
to the 1ooo
c/
s
filter
should
now take place
at
the
900
c/
s
line. If this is not the
case
repe•
a t
from item
2.
G. Finally reset the Writing
Speed on
250 mm
or
lower if the large
figures
are
being used,
and
to
a figure of 500
mm
or
less if using
the
small figures.
To
complete
the
synchronization sequency
the B.F.O. Type
10·
2 2
must
be
synchronized
with the
f~·equency
cal·ibration
on
the paper.
1. Rotate main
scale of
B.F.O. manually until it
corresponds
to the
frequency denoted by the
stylus,
firstly moving it to
a
higher
fre-
quency
and
then rotating it back until it
arrives on
the
desired
frequency. This will take up
any
possible backlash with the
gears
of
the B.F.O.
2.
Move the
switch AUTOMATIC SCANNING of
the B.F.O. to the
"on"
position.
All
units
should
now be in
complete synchronization and on
switching
the toggle
switch of
the PAPER DRIVE
on
the Recorder
to
"start",
the
combination
will
operate
in
complete
unison.
EXAMPLES OF APPLICATIONS
Applications
for the
combined
B.F.O. 1022
and Level
Recorder
2305
have
been described,
and
illustrated, under this heading in the
earlier
phase
of
this manual.
Now one
important use
for
the treble
combination,
B.F.O.
+
Level Recorder
+
Spectrometer
(i.e. the
AF
Response
and Spectrum Re-
corder Type 3332)
will be
described,
followed
by another example
using
the
Spectrometer and
Level Recorder with the
exclusion of
the B.F.O. 1022
section.
Automatically Recording Harmonics.
The
Type
3332
combination
is well-suited
for
the
automatic recording of
harmonic
distort•
i on,
as
the
Spectrometer can be switched
to
select any
specific
harmonic
component of
the
fundamental
in use, up to
and
including
49

Hide quick links: