Advertisement

paasche

D200 Air Compressor

1/6 HP, 110V, 60Hz, 1.5 AMP, .7 CFM @ 20 PSI,
70 PSI, Shipping Weight: 5.2 kgs (11.6 lbs.)
D200-50 Air Compressor
1/6 HP, 220V, 50Hz, 1.0 AMP, .6 CFM @ 20 PSI,
70 PSI, Shipping Weight: 5.2 kgs (11.6 lbs.)

OPERATION: OILLESS - NEEDS NO LUBRICATION

The compressor is maintenance free. To avoid mal-functions and
premature wear and tear, the following points should be
observed.
1. WARNING: Plug the power cord into a 110V.-60Hz or 220V.-
50Hz Cycle grounded outlet depending on the Model
purchased. Do not use an adapter to by-pass the grounding
feature. Do not operate compressor in a wet area.
2. Place compressor on a level surface, preferably on the floor.
3. Carrying compressor while operating is not advisable.
4. Do not let the compressor run unnecessarily, i.e. the unit
should be switched off when the airbrush is not being used.
5. Always remove the power cord from the electric outlet when
making adjustment or changing parts.
6. Always provide plenty of ventilation while spraying.
7. Never smoke or eat while spraying.
8. Wear a respirator and eye protection when spraying.

TROUBLE-SHOOTING:

1. Low air flow
Possible causes:
-Reed valve (#33)
or air valve (#38)
damaged
-Diaphragm (#31) damaged
-6 screws (#42) are too loose
-Air hose leaking
2. Noisy operation
Possible causes:
-6 screws (#42) are too tight
-Bearing fault
3. Humming but does not work
Possible causes:
-6 screws (#42) are too tight
-Armature fault
Paasche Airbrush Company
4311 North Normandy
Chicago, IL 60634-1395
Phone: 773-867-9191 • Fax: 773-867-9198
Website: paascheairbrush.com
E-Mail: info@paascheairbrush.com
What to do:
-Change the defective air
valve plate or air valve
-Change the diaphragm
-Tighten the screws
-Check seal, or change
What to do:
- Loosen the screws, and
then tighten them equally.
Do not over tighten.
-Return to Factory.
What to do:
-Loosen the screws, and
then tighten them equally.
Do not over tighten.
-Return to the Factory.
INSTRUCTION AND PARTS LIST D200&D200-50, 8/2005
Supercedes Instructions & Parts List D200&D200-50, 1/2004
WARNING: When a flammable liquid is sprayed, there
may be danger of fire or explosion especially in a closed
room: keep compressor at least 20 feet away from areas
where hazardous concentrations of flammable vapors
are likely to occur. Disconnect power before servicing.
ATTENTION: Lorsqu'un liquide inflammable est
pulverise, il peut y avoir danger d'incendie ou
d'explosion, specialement dans une piece fermee;
garder le compresseur a au moins 20 pieds des
endroits ou des concentrations dangereuses de
vapeurs inflammables sont susceptibles de se
produire. Debrancher avant toute maintenance.
4. Does not work
Possible causes:
-Armature fault
NOTICE:
If you need to disassemble the compressor, take care to note the
position and orientation of the parts to assure the correct re-
assembly.
D200 Air Compressor, 110V.,60Hz.
D200-50 Air Compressor, 220V., 50Hz.
Manufactured in Taiwan for Paasche
What to do:
-Return to the Factory.
Note:
PLUG
Note:
PLUG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for paasche D200

  • Page 1 INSTRUCTION AND PARTS LIST D200&D200-50, 8/2005 paasche Supercedes Instructions & Parts List D200&D200-50, 1/2004 D200 Air Compressor WARNING: When a flammable liquid is sprayed, there may be danger of fire or explosion especially in a closed room: keep compressor at least 20 feet away from areas 1/6 HP, 110V, 60Hz, 1.5 AMP, .7 CFM @ 20 PSI,...
  • Page 2 Page 2 Paasche D200 or D200-50 Air Compressor D200 or D200-50 AIR COMPRESSOR PARTS Part No. Description Part No. Description D200-01 Housing (110V.,60HZ) D200-24 Washer Part No. Description D200-01-50 Housing (220V.,50HZ) D200-25 Screw D200-48 Screw D200-02 Armature D200-27 Screw D200-49...

This manual is also suitable for:

D200-50

Table of Contents