Therafin 31070 Manual

Top drop attaching clamp system for quantum tb3

Advertisement

Quick Links

TOP DROP ATTACHING
CLAMP SYSTEM

PARTS DESCRIPTION

Lock Nut
Mounting
Slot
Mounting
Hole
Step
Collar
Base
Unit

PARTS LIST

Description
Base Unit . . . . . . . . . . . . . . . . . . . . . . . . 2
Step Collar . . . . . . . . . . . . . . . . . . . . . . . . 2
Handle . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Spacer . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Allen Wrench . . . . . . . . . . . . . . . . . . . . . . . 2
Washer, Black . . . . . . . . . . . . . . . . . . . . . . 2
Tension Washer, Silver . . . . . . . . . . . . . . . . . . 2
1-1/4" Button Head Cap Screw . . . . . . . . . . . . . . 2
1-3/4" Button Head Cap Screw . . . . . . . . . . . . . . 2
1/2" Flat Head Cap Screw . . . . . . . . . . . . . . . . 4
T-Nut . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Lock Nut
. . . . . . . . . . . . . . . . . . . . . . . . 2
31070
Flat Head Screw
T-Nut
Black Washer
Tension Washer
Button Head Cap Screw
Spacer
Quantity

ADJUSTING CLAMP TO ARMPAD THICKNESS

The Top Drop Attaching Clamp System can be adjusted to fit a
compressed armpad thickness from 5/8" to approximately 1-15/32".
The actual armpad thickness will be more, but the Top Drop Clamp
compresses the armpad in the "locked" position.
A clamping range from 5/8" to approximately 1" can achieved by
using the 1-1/4" Button Head Cap Screw to hold together the Base
Unit, Step Collar, and Handle.
A clamping range from 1-3/32" to approximately 1-15/32" can be
achieved by using the 1-3/4" Button Head Cap Screw to hold together
the Base Unit, Step Collar, Spacer, and Handle.
Each step in the Step Collar adds approximately 3/32" to the
clamp's adjustment range.
5/8"
Fully Nested Step Collar
23/32"
Step Collar adjusted to first step
13/16"
Step Collar adjusted to second step
29/32"
Step Collar adjusted to third step
1"
Fully Expanded Step Collar
adjusted to fourth step
With Washer
PAGE 1 OF 2 - 08718
1-3/32"
1-3/16"
1-9/32"
1-3/8"
1-15/32"

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 31070 and is the answer not in the manual?

Questions and answers

Summary of Contents for Therafin 31070

  • Page 1 TOP DROP ATTACHING The Top Drop Attaching Clamp System can be adjusted to fit a CLAMP SYSTEM 31070 compressed armpad thickness from 5/8" to approximately 1-15/32". The actual armpad thickness will be more, but the Top Drop Clamp compresses the armpad in the “locked” position.
  • Page 2 (OPTIONAL) USING MOUNTING HOLES Locked Position Therafin’s optional Invisible Tray Attachment System (comes with attaching hardware) may be used with Top Drop Clamps if you don’t want to drill holes through the tray. You would use the countersunk 4. When fitted correctly, armpad will compress between Base Unit and mounting holes on the Top Drop Clamps with the Invisible Tray Handle, to hold entire assembly secure.
  • Page 3 Caution: Always tighten all fasteners securely and inspect fasteners regularly for tightness. Product Identification Bolts To Operate Installation and Assembly Use with Therafin Top Drop Hardware. Image below shows installed device on Right armrest Therafin Top Drop Hardware Step 1: Remove bolts from Pride TB3 Armrest Pad.
  • Page 4 Therafin Corporation. This replacement warranty does not include misuse or neglect of the product. T h e r a f i n C o r p o r a t i o n...

Table of Contents