DRYDEN AQUA DA-GEN User Manual

DRYDEN AQUA DA-GEN User Manual

Hide thumbs Also See for DA-GEN:

Advertisement

DA-GEN
Dryden Aqua Generator
USER MANUAL
The DA-GEN
®
is an innovative water treatment system and additional an intelligent pool controller. The DA-GEN
combines Hydrolysis with Electrolysis with a low mineral content.
The Hydrolysis produces free radicals and other oxygen compounds like ozone, peroxide and persulfate. All these
oxidants destroy organic substances and pathogens in the water. Free radicals are the strongest oxidants we
know. They oxidise and decompose in a few seconds. To guarantee a safe residual disinfection the DA-GEN
produces a very small amount of chlorine. In combination with Dryden DAISY
content of 1 to 2 kg MgCl
or NaCl per m
2
The DA-GEN
®
also controls all your pool equipment centrally. Thanks to WiFi you can check and control your
pool system 24/7.
Control panel
4
1
2
3
110-230 V
1
Connection cell
Gas detector connection
2
5
3
Main 230V connection
6
4
ON/OFF switch
Heating ON/OFF
Status of the auxiliary relays
Current time
Production intensity
in %
(normally 40-100%)
Automatic measurements: pH/redoX/
free chlorine/conductivity
(according to options)
Status of filtration relay
(see chapter 12- Filtration)
man
Manual
aut
Automatic
Communication display – mother board
PLUS key
MINUS key
Modify value/selection
Modify value/selection
Shortcut Backwash
Shortcut Light
(press 3s)
(press 3s)
1. DESCRIPTION
3
.
5
6
4 Amp fuse for panel and cell
4 Amp fuse relays
2. MAIN SCREEN
12:30
1 2 3 4
hydrolysis
100
%
measures
7.4
pH
700
Rx
mV
0.30
Cl
ppm
man
off
OK key
Select/confirm
®
®
we need a very low mineral
Cell
4
1
5
2
Water temperature
If the cover is open the filtration speed is "medium" (if with
Cover
frequency controlled pump)
Polarity 1 /
Pol 1
Waiting time
---
Filtration stopped due to lack of water flow
Flow
25º
Lack of conductivity or salt / low water temperature / scale on
Low
cell / exhausted cell
Pol 1
Cover
LOW
7.4 OFF
7.0
AL3
7.4
pH Setpoint
700 OFF
Function of pH dosing pump
FL1
AL3
ON/OFF
0.30 FL2
AL3
Maximum dosing time exceeded
FL1
TANK
7.0
Setpoint pH minimum (if using pH-Minus and pH-Plus)
man
off
Additional chlorine pump (optional)
ON/OFF
FL 1
Flow alarm (Paddle/Gas)
700
Minimum Redox Setpoint
Maximum dosing time exceeded
AL3
0.30
Free Chlorine Minimum Setpoint
FL 1
Flow alarm (Paddle/Gas) /
AL3
Maximum dosing time exceeded
TANK
Low level pH-Minus bottle
Lights
Manual /
Automatic
man
aut
UP key
Navigation up
1
®
®
1
Cell
2
Gas detector connector
3
Cell connector
3
Cell housing
4
5
Gas detector (internal)
1
Except DA-GEN 150
Polarity 2
Pol 2
(check working hours)
(
to reset the alarm)
(
to reset the alarm)
Flow alarm rotameter Cl
FL 2
(
to reset the alarm)
RETURN/ESCAPE
DOWN key
key
Navigation down
1
2
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DA-GEN and is the answer not in the manual?

Questions and answers

Summary of Contents for DRYDEN AQUA DA-GEN

  • Page 1 The Hydrolysis produces free radicals and other oxygen compounds like ozone, peroxide and persulfate. All these oxidants destroy organic substances and pathogens in the water. Free radicals are the strongest oxidants we know. They oxidise and decompose in a few seconds. To guarantee a safe residual disinfection the DA-GEN ®...
  • Page 2: System Installation

    In case of sharing the power supply with other devices please consult a technician in order to dimension a correct installation. Maximum Maximum Product consumption Product consumption DA-GEN 24 90 W DA-GEN 240 680 W DA-GEN 45 125 W DA-GEN 360 1000 W DA-GEN 90...
  • Page 3: System Settings

    5. INITIAL WATER ADJUSTMENTS Water adjustments Adding activator/salt to the water We recommend to add 1 to 2 kg magnesium chloride (MgCl ) or normal salt (NaCl) Adjust the alkalinity between 100 and 200 ppm. per m of water. The TDS should be at around 1200. It is recommended to mix them, for example in a ratio of 1:1 to 1:3 (MgCl :NaCl).
  • Page 4: Temperature Calibration

    10. MEASUREMENTS 10.1 10.2 10.3 10.1 Measurements: Adjustment of setpoints and measuring probes. 10.2 Setpoints for each measurement. 10.3 Setpoints: pH: 7.0-7.4; redox: 600 - 800 mV; free chlorine: 0.1- 0.5 ppm; conductivity: ~ 2000 μS 10.1 pH Calibration pH module 10.11 Calibration of pH probe: Recom- 10.11 10.12...
  • Page 5: Conductivity Calibration

    10.4 Redox Calibration The redox value shows the oxidation/reduction potential and is used to determine the sterility of the water. Adjusting the ideal redox level (setpoint) is the last step in the system start up sequence. Redox control 10.41 Calibration of the redox probe: 10.41 10.42 10.43...
  • Page 6: Manual Mode

    * Note: Mode only visible if the temperature probe is installed and/or heating is activated in the “Installer Menu”. 13. AUTOMATIC BACKWASH 13.1 13.1 Backwash Mode with Besgo Valve: The DA-GEN is configured for automatic backwash with Besgo. Use AUX 2! • Mode: Choose Auto •...
  • Page 7 Open the WIFI box and unscrew the cabels in the box. Put the cable through the cable hole at the DA-GEN controller box and plug it in. Connect the cable then again in the WIFI box and close it Connection...
  • Page 8: Auxiliary Relays

    18. AUXILIARY RELAYS 18.1 18.2 18.3 18.2 It is possible to control up to 4 extra auxiliary 110-230 V DRY CONTACT max. 3.15 A relays (water attractions, dosing pumps, etc). 1 2 3 4 5 6 7 8 9 10 11 12 13 14 In default setting you will only see two available relays: APF ®...
  • Page 9: Troubleshooting

    20. TROUBLESHOOTING Blank display Excess of chlorine in the water • Check if ON/OFF switch is illuminated. • Lower hydrolysis cell intensity. • Check the connection wire between display and motherboard. • If your system includes automatic Redox control, check the Redox setpoint value. •...
  • Page 10: Service Menu

    DA-GEN ® PASSWORT MENU INSTALLATEUR: Dryden Aqua Generator ASK YOUR SUPPLIER OR POOL BUILDER SERVICE MANUAL A) ELECTRICAL CONNECTIONS CONNECT ALL THE SENSORS CAREFULLY, A BAD CONNECTION MAY CAUSE IRREPARABLE DAMAGE TO THE DEVICE Conductivity probe yellow 110-230 V DRY CONTACT max.
  • Page 11: Service Settings

    D) SERVICE SETTINGS D.2 Parameters related to external devices Standard Range Dimension Description factory value 3 Flow mode select 0 - FL1 Lack of water flow - It turns off only the cell. Val: 1 0001 1 - FL1 Lack of water flow - It turns off everything (cells, pumps,...) 1 (Redox) 2 - FL2 Lack of water flow - It turns off only the cell.
  • Page 12: Dosing Pumps

    F) DOSING PUMPS F.2 There are 2 modes for the pH dosing pump: F.3 Normal: Delay - Delay time between detection of incorrect value and the start of dosing. F.4 Repetitive: With the two timers you can programm the ON and OFF time of the dosing pump Scaling: Proportional reduction of the dosing time (Pump On time) when getting close to the setpoint.