IMPORTANT SAFETY INFORMATION

INSTALLER: Please read all instructions before servicing
this equipment. Pay attention to all safety warnings and
any other special notes highlighted in the manual. Safety
markings are used frequently throughout this manual to
designate a degree or level of seriousness and should not
be ignored. WARNING - Indicates a potentially hazardous
situation that if not avoided, could result in personal injury or
death. CAUTION - Indicates a potentially hazardous situation
that if not avoided, may result in minor or moderate injury or
property damage.
WARNING:
The safety information listed in this manual must
be followed during the installation, service, and
operation of this unit. Unqualified individuals
should not attempt to interpret these instructions
or install this equipment. Failure to follow safety
recommendations could result in possible
damage to the equipment, serious personal
injury or death.
WARNING:
Improper installation, service, adjustment, or
maintenance may cause explosion, fire, electrical
shock or other hazardous conditions which may
result in personal injury or property damage.
Unless otherwise noted in these instructions,
only factory authorized kits or accessories may
be used with this product.
WARNING:
Do not install this furnace if any part has been
submerged under water. A flood damaged furnace
is extremely dangerous. Attempts to use the
furnace may result in fire or explosion. A qualified
service agency should be contacted to inspect the
furnace and to replace any electrical or control
system parts that have been wet or under water.
• To minimize equipment failure or personal injury, it is
essential that only qualified individuals install, service, or
maintain this equipment. If you do not posses mechanical
skills or tools, call your local dealer for assistance.
• Follow all precautions in the literature, on tags, and on
labels provided with the equipment. Read and thoroughly
understand the instructions provided with the equipment
prior to performing the installation and operational
checkout of the equipment.
• Use caution when handling this appliance or removing
components. Personal injury can occur from sharp metal
edges present in all sheet metal constructed equipment.
• Do not store any of the following on, or in contact with,
the unit: Rags, brooms, vacuum cleaners, or other
cleaning tools, spray or aerosol cans, soap powders,
bleaches, waxes, cleaning compounds, plastics or plastic
containers, paper bags or other paper products, gasoline,
kerosene, cigarette lighter fluid, dry cleaning fluids, paint
thinners, or other volatile fluids.
• The installer should become familiar with the units wiring
diagram before making any electrical connections to the
unit. See
Figure 32 (page 31)
the unit wiring label.
• Always reinstall the doors on the furnace after
servicing. Do not operate the furnace without all doors
and covers in place.
REQUIREMENTS & CODES
WARNING:
The information listed below must be followed
during the installation, service, and operation
of this furnace. Failure to follow safety
recommendations could result in possible
damage to the equipment, serious personal
injury or death.
• This furnace must be installed in accordance with these
instructions, all applicable local building codes and the
current revision of the National Fuel Gas Code (NFPA54/
ANSI Z223.1) or the Natural Gas and Propane Installation
Code, CAN/CSA B149.1.
• Use only with type of gas approved for this furnace. Refer
to the furnace rating plate.
• Install this furnace only in a location and position as
specified on
.
page 5
• Provide adequate combustion and ventilation air to the
furnace space as specified on
&
.
page 8
page 9
• Provide adequate clearances around the vent air intake
terminal as shown in
Figure 7 (page 11)
,
, &
11)
Figure 9 (page 12)
• Combustion products must be discharged outdoors.
Connect this furnace to an approved vent system only,
as specified on
page 9
12
.
• Never test for gas leaks with an open flame. Use
a commercially available soap solution to check all
connections. See
page 20
• This furnace is designed to operate with a maximum
external pressure rise of 0.5 inches of water column.
Consult the rating plate for the proper circulating air flow
and temperature rise. It is important that the duct system
be designed to provide the correct flow rates and external
pressure rise. An improperly designed duct system can
result in nuisance shutdowns, and comfort or noise
issues.
• When supply ducts carry air circulated by the furnace
to areas outside the space containing the furnace, the
return air shall also be handled by duct(s) sealed to the
furnace casing and terminating in the conditioned space.
See
.
page 13
• A gas-fired furnace for installation in a residential garage
must be installed as specified on
• This furnace is not approved for installation in mobile
homes. Installing this furnace in a mobile home could
cause fire, property damage, and/or personal injury.
• The
Commonwealth
compliance with regulation 248 CMR 4.00 and 5.00 for
installation of through – the – wall vented gas appliances
as follows:
,
Figure 33 (page 36)