Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Safety Guidelines
This manual contains information that is very important to know
and understand. This information is provided for safety and to
prevent equipment problems. To help recognise this information,
observe the following symbols.
Danger indicates an imminently hazardous
situation which if not avoided WILL result
in death or serious injury.
Warning indicates a potentially hazardous
situation which if not avoided, COULD
result in death or serious injury.
Caution indicates a potentially minor or
moderate injury.
Notice indicates important information,
that if not followed, may cause damage to
equipment.
Unpacking
After unpacking the unit, inspect carefully for any damage that
may have occurred during transit.
Do not operate unit if damaged during
shipping, handling or use.
General Safety Information
The operator of this product must take the necessary precautions
to prevent the level of danger indicated by these symbols. The
operator is required to read and understand this instruction
manual and all safety warnings, labels etc.
Any employer allowing the use of this product in their field of work
must distribute this instruction manual to all users. The employer
must also ensure all users read, understand and follow the
instructions as described in the manual, safety warnings, labels,
etc.
Read and understand all safety warnings
and instructions before operating this
product. Failure to read and follow all
safety warnings may result in serious
personnel injury or death. Property
damage and/or product damage may also
occur if all warnings are not followed.
76470
Purchased Nitrogen Cart may not be representative of the image shown
www.pclairtechnology.com
1.
Do not expose the product to flammable gases,
vapours or fumes
2.
Do not store flammable gases in or near this product
3.
Never use flammable or toxic solvents to clean the
product or any of the unit's parts
4.
Never remove or alter any safety warning labels, tags,
etc. located or provided with product.
5.
Follow all directions for maintenance.
The use of other than genuine PCL
replacement parts may result in reduced
equipment performance. Repairs must be
performed by authorised repair personnel,
otherwise the warranty will be void.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the N72 and is the answer not in the manual?

Questions and answers

Summary of Contents for pcl N72

  • Page 1 PART NUMBER SERIAL NUMBER N72 Nitrogen Mobile Unit Inflator User Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
  • Page 2: General Specifications

    N72 Mobile Nitrogen Unit Inflator User Manual General Specifications Max Inlet Recommended Max Inflation Min Inflation Display Units of Electrical Variant Supply Supply Pressure Pressure Resolution Measurement Supply 188.5psi/13bar/ 14.5psi/1bar/100 174psi/12ba 4psi/0.3bar/ 1psi /0.1bar/ psi/bar/kPa 90 V a.c. to 240 V a.c.
  • Page 3 Software Version—i.e. 3.2.3 Software Variant—i.e. 366 ‘PCL’ When PCL is shown press ‘Start’ or ‘N2’ button. The screen will then show ‘NPC’. This is the first of the four parameter settings. These parameters may be scrolled up and down to view by pressing the + or - but- tons.
  • Page 4: Battery Charging

    N72 Mobile Nitrogen Unit Inflator User Manual Unit usage monitoring Hours of N2 cycling Numbers of complete N2 cycles Number of top-offs These can be adjusted if required by the operator by:- Pressing + and - buttons simultaneously (long beep can be heard) The screen at this stage should display CNT.
  • Page 5 N72 Mobile Nitrogen Unit Inflator User Manual Operation 1. Firmly attach the output tyre hoses to the target tyres and ensure that leaks do not exist. 2. Set the Tyre pressure with the + and – buttons on the front panel.
  • Page 6 N72 Mobile Nitrogen Unit Inflator User Manual For inspection and checking of The PCL tyre inflators are exclusively approved for the dispensing of air/N . Each use which doesn't follow this the actual tyre pressure: purpose as well as modifications to the product will be deemed to be improper use.
  • Page 7 N72 Mobile Nitrogen Unit Inflator User Manual Instructions for changing the Inside the top half bowl should be the ozone filter which is black in colour. This can simply be pulled out with a small filter elements on the integral amount of pressure.
  • Page 8: Unit View

    N72 Mobile Nitrogen Unit Inflator User Manual Unit view Filter Indicator LCD Display Battery Voltage Indicator Stop-Fill Valve On/Off Switch Hose Hooks Charge Status LED Nitrogen Purity Test Point Handle Output Hoses (x4) Charger Cable Tray 125mm castors www.pclairtechnology.com...
  • Page 9 4. Remove 4 off M5 Nuts retaining battery charger cage. connector on a PCL Nitrogen Analyser unit (N2A001) which will 5. Discard old charger noting local WEEE regulations.
  • Page 10 N72 Mobile Nitrogen Unit Inflator User Manual Trouble Shooting Guide/Error Messages Problem Possible Cause Solution No display No power connected Switch power on No inflation process Tyre is below 3 psi Press start button Faulty connector Replace faulty connector Buzzer does not sound...
  • Page 11 FITNESS FOR A PARTICULAR PURPOSE. Determination of the suitability of the unit for the use contemplated by the customer is the sole responsibility of the customer. PCL shall not, under any circumstances, be liable in contract, tort or otherwise (including negligence and strict liability) for indirect, special, incidental, or consequential damages, and PCL's total liability shall not exceed the net purchase price for the unit.
  • Page 12: Calibration Certificate

    2014/30/EU (EMC directive) confirmed by report No. TRA-034746-36-02A • 2014/35/EU (LOW Voltage Directive). • National regulations EN12645 : 2014, French National Approval LNE-3345—Rev 0, report no. LNE-33471—Rev 0 and Portugal Approval (IPQ) report no. 245.30.17.3.18 Mark McCaughey Technical Director on behalf of PCL...

Table of Contents