pcl N72 User Manual

Nitrogen mobile unit
Hide thumbs Also See for N72:

Advertisement

PART NUMBER
SERIAL NUMBER
N72 Nitrogen Mobile Unit Generator User Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

Safety Guidelines

This manual contains information that is very important to know
and understand. This information is provided for safety and to
prevent equipment problems. To help recognise this information,
observe the following symbols.
Danger indicates an imminently hazardous
situation which if not avoided WILL result
in death or serious injury.
Warning indicates a potentially hazardous
situation which if not avoided, COULD
result in death or serious injury.
Caution indicates a potentially minor or
moderate injury.
Notice indicates important information,
that if not followed, may cause damage to
equipment.

Unpacking

After unpacking the unit, inspect carefully for any damage that
may have occurred during transit.
Do not operate unit if damaged during
shipping, handling or use.

General Safety Information

The operator of this product must take the necessary precautions
to prevent the level of danger indicated by these symbols. The
operator is required to read and understand this instruction
manual and all safety warnings, labels etc.
Any employer allowing the use of this product in their field of work
must distribute this instruction manual to all users. The employer
must also ensure all users read, understand and follow the
instructions as described in the manual, safety warnings, labels,
etc.
Read and understand all safety warnings
and instructions before operating this
product. Failure to read and follow all
safety warnings may result in serious
personnel injury or death. Property
damage and/or product damage may also
occur if all warnings are not followed.
76474
Purchased Nitrogen Cart may not be representative of the image shown
www.pclairtechnology.com
1.
Do not expose the product to flammable gases,
vapours or fumes
2.
Do not store flammable gases in or near this product
3.
Never use flammable or toxic solvents to clean the
product or any of the unit's parts
4.
Never remove or alter any safety warning labels, tags,
etc. located or provided with product.
5.
Follow all directions for maintenance.
The use of other than genuine PCL
replacement parts may result in reduced
equipment performance. Repairs must be
performed by authorised repair personnel,
otherwise the warranty will be void.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the N72 and is the answer not in the manual?

Questions and answers

Summary of Contents for pcl N72

  • Page 1 PART NUMBER SERIAL NUMBER N72 Nitrogen Mobile Unit Generator User Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
  • Page 2 N72 Mobile Nitrogen Unit Generator User Manual General Specifications Max Inlet Recommended Min Inflation Display Units of Electrical Variant Supply Supply Pressure Pressure Resolution Measurement Supply 188.5psi/13bar/ 14.5psi/1bar/100 102 psi/7 4psi/0.3bar/ 1psi /0.1bar/ psi/bar/kPa 90 V a.c. to 240 V a.c.
  • Page 3 Nitrogen being produced ensure the unit is turned on inlet port of the Filter Unit. Then connect your outlet hose to the then remove the valve cap and push the connector on a PCL outlet port. Nitrogen Analyser unit (N2A001) which will automatically give you a purity readout.
  • Page 4 Air Inlet Solenoid SPR4500 Battery 7 Ah, 12 V d.c. The PCL tyre inflators are exclusively approved for the dispensing of air/N . Each use which doesn't follow this purpose as well as modifications to the product will be deemed to be improper use. The manufacturer is not liable for damages caused by improper use, the risk lies solely with the user.
  • Page 5 N72 Mobile Nitrogen Unit Generator User Manual Instructions for changing the Inside the top half bowl should be the ozone filter which is black in colour. This can simply be pulled out with a small filter elements on the integral amount of pressure.
  • Page 6 N72 Mobile Nitrogen Unit Generator User Manual Unit view Output Port Filter Indicator LCD Display Battery Voltage Indicator On/Off Switch Charge Status LED Nitrogen Purity Test Point Handle Charger Cable Tray 125mm castors www.pclairtechnology.com...
  • Page 7 N72 Mobile Nitrogen Unit Generator User Manual Trouble Shooting Guide/Error Messages Problem Possible Cause Solution No display No power connected / Battery needs charging Switch power on / Charge Battery No generation process System has reached 8 bar and shut off Wait for pressure to drop &...
  • Page 8 PCL warrants the components of each unit to which this Limited Warranty applies against defects in materials and workmanship for a period of twelve (12) months from date of sale (as evidenced by bill of sale or equivalent) or for a period of eighteen (18) months from date of shipment from PCL manufacturing facility (identifiable by the serial number and noted on original bill of lading from the manufacturing facility), whichever period is shorter.

Table of Contents