Download Print this page

Cleaning Solutions; Troubleshooting - Jet JPW-20 Operation Manual

20 gallon parts washer – heavy duty

Advertisement

Available languages

Available languages

Cleaning Solutions

Aqueous-based cleaning solution only with a PH range of 7 - 8
WARNING
The pump of your Parts Washer may be damaged if you use solvents
other than those listed above such as methyl ethyl ketone (MEK),
Perchloroethylene or trichloroethylene.
DO NOT USE FLAMMABLE SOLVENTS.

Troubleshooting

The only trouble you should ever experience with your Parts Washer is reduced volume flow or no flow of
cleaning liquid from the flex hose nozzle. The probable cause is foreign matter in the flex hose.
Corrective Procedure
1.
Check if indicator light on switch box is lit.
2.
Using an insulated handle screwdriver, lightly touch tip of housing of motor.
A light oscillation magnetic pull indicates power is reaching the motor.
3.
Disconnect power plug, remove flex hose from pump flow-out line.
4.
Remove front of pump housing by removing 3 screws. Clean any foreign matter lodged around impeller.
5.
Reassemble in reverse order.
WARNING
1. Do not smoke near Parts Washer
2. Do not use Parts Washer near an open flame
3. Use only in a well ventilated area
4. Do not prop up lid or impede the function
of the fusible link
4
Do not fill to maximum tank capacity
Fill only to 11 gallon (41.8 litre) working capacity

Advertisement

loading

This manual is also suitable for: