Specifications:

Model
Sound conversion principle
Diaphragm size
Directional characteristic
Frequency range
Field transmission factor
Output impedance
Equivalent noise level, A-
weighted
Sound pressure level limit for K
<0.5%
Signal-to-noise ratio
Connection
Power supply

Troubleshooting:

The following overview serves as an aid for quick troubleshooting. If you should be uncertain,
contact the manufacturer, the dealer or the corresponding specialist personnel. Never open the
device yourself!
Symptom
No tone
Delayed tone
If the specified fixes have not been successful, please contact our service staff. The contact
details can be found at
FAME CM2
Condenser microphone
1 inch large diaphragm
Cardioid characteristic
20 Hz – 20 kHz
7 mV / Pa (bei 1 kHz)
200 Ohm
24 dB-A
125 dB
76 dB
XLR3
Phantom power +48 V
Troubleshooting
Check the cable for damage (cuts, extreme kinks,
etc.) and replace if necessary.
Check the wiring. Connectors must be fully
inserted and snap into place!
Check if the 48V phantom power is switched on at
the console/interface.
Check the setting of the preamplifier on the
console/interface/etc.
Change the buffer size in the DAW settings. The
lower the number, the lower the latency. (Note:
with a low buffer size, the machine requires higher
performance. Depending on the computer, this
can lead to higher performance losses). For more
information, please refer to the manual of each
digital audio workstation.