If problems arise contact THE PUMP IF IT IS DAMAGED. Hozelock customer services. NEVER USE THE POWER CABLE TO LIFT THE PUMP. Every Hozelock Flood Pump is carefully tested and packed during assembly. Limitations On receipt, check that the pump has not The pump can be completely or partially been damaged during transport.
Page 5
When set up for automatic Overload protection operation the pump will turn on at a water depth of 400mm, and turn • The Hozelock Flood Pump has off at a water depth of 190mm a built in thermal protection switch. (Fig 1) The pump stops if an overload condition occurs.
Blocked impeller Unplug from the electricity supply and remove possible obstructions from the impeller (Figs 8 & 9) Damaged motor Contact hozelock customer services for assistance Pump has overheated Pump contains thermal protection - check if pump case is hot, and if so, allow to cool...
Page 7
(Figs 8 & 9) intermittently impeller The temperature of the Only use with fluids below 35ºC fluid is too high Faulty motor Contact Hozelock customer services for assistance Water is leaking Inlet assembly not tight Tighten from the outlet enough...
Need help?
Do you have a question about the Flood Pump 7825 and is the answer not in the manual?
Questions and answers