INTRODUCTION Welcome! The Lumin Smart Panel (LSP) is a stand-alone product that extends the capability of an existing circuit breaker panel (or “electrical panel”) by providing measurement and remote control of up to twelve (12) circuits in a home or building. The function of the circuit breaker panel remains the same and is not impacted.
NOTE: The LSP Circuit Label & CT Table (provided with the LSP) must be completed and delivered to the home/building owner upon the successful installation of the LSP. A completed LSP Circuit Label & CT Table is required in order for users to set up their Lumin account.
PRE-INSTALLATION CHECKLIST Items in the Box 1 LSP with Conduit, Conduit 2 Mounting Brackets 1 Pair of 200A Current Transformers Bushings & Wire Whips Attached (Surface-mounted Installation) (A second pair is optional) NOTE: Additional items include an antenna, installation hardware, a LSP Circuit Label & CT Table, an Account Setup Guide and an Installation Overview.
Lumin Smart Panel INSTALLATION MANUAL Installation Steps STEP 1. Turn Off Main Feed and Remove Electrical Panel Cover WARNING: HIGH VOLTAGE. Tools: Screwdriver...
Page 10
STEP 2 (Flush-Mount Only). Cutout and Remove Drywall Drywall Cutout Option A Drywall Cutout Option B Tools: Tape measure, level (optional) and drywall saw or suitable alternative NOTE: Cut and remove enough drywall to accommodate the LSP’s wire whips. Consider drywall cutout “Option B”...
Page 11
Lumin Smart Panel INSTALLATION MANUAL STEP 3. Knock Out One 2” Hole in Electrical Panel for 2” Conduit WARNING: HIGH VOLTAGE. Tools: Knockout punch or suitable alternative NOTE: Exact hole location in electrical panel may very depending on spacing constraints;...
Page 12
STEP 4. Measure and Mark Hole Locations for Mounting the LSP Surface-mounted installation Flush-mounted installation Tools: Tape measure and level (optional) NOTE: Ensure to mark the applicable hole locations for your installation type (flush-mount vs. surface-mount mounting brackets). Exact hole locations may vary depending on existing conditions.
Page 14
STEP 6. Attach the LSP’s Antenna and Guide the LSP’s Wire Whip Through the Electrical Panel Attach Attach Antenna Antenna Surface-mounted installation Flush-mounted installation WARNING: HIGH VOLTAGE. NOTE: Attach the LSP’s antenna (provided with your LSP) and then guide the wire whip through the hole in the electrical panel.
Page 15
Lumin Smart Panel INSTALLATION MANUAL STEP 7. Secure the LSP to the Wall/Bracket and Electrical Panel Surface-mounted installation Flush-mounted installation WARNING: HIGH VOLTAGE. Tools: Drill, screws (x4), washers (x4) and nuts (x4: surface-mount only) NOTE: Lift the LSP to align with the mounting holes and secure it directly to the wall (flush- mount installation) or mounting brackets (surface-mount installation) utilizing the hardware provided.
Page 16
STEP 8. Connect the LSP Ground Wire to the Ground Bar Ground Wire WARNING: HIGH VOLTAGE. Tools: Screwdriver NOTE: Connect the bare copper ground wire from the LSP to the existing ground bar in the electrical panel (exact location of ground bar may vary).
Page 17
Lumin Smart Panel INSTALLATION MANUAL STEP 9. Connect the LSP Power Cable Harness Neutral (white) Line B (red) to Phase B Breaker Line A (black) to Phase A Breaker WARNING: HIGH VOLTAGE. Tools: Screwdriver and wire stripper NOTE: Connect the LSP wire labeled “Neutral” to the existing neutral bar in the electrical panel;...
Page 18
STEP 10. Select A Circuit Breaker to Connect to the LSP, Turn it Off and Disconnect Load Disconnect Load Turn Off Circuit WARNING: HIGH VOLTAGE. Tools: Screwdriver...
Page 19
Lumin Smart Panel INSTALLATION MANUAL STEP 11. Connect a LSP Wire Labeled “Line # A” to the Circuit Breaker Line # A WARNING: HIGH VOLTAGE. Tools: Screwdriver and wire stripper NOTE: All LSP wires labeled “Line # A” must connect to a breaker. Lines 1-6 (6 AWG wire) can connect to circuit breakers rated up to 60 amps and lines 7-12 (10 AWG wire) can connect to circuit breakers rated up to 30 amps.
Page 20
STEP 12. Connect a LSP Wire Labeled “Line # B” to the Load and Then Turn the Circuit Breaker Back On Line # B WARNING: HIGH VOLTAGE. Tools: Wire stripper and wire nut NOTE: All LSP wires labeled “Line # B” must connect to a load wire via a wire nut (ensuring a tight connection).
Page 21
Lumin Smart Panel INSTALLATION MANUAL STEP 13. Record Circuit Label/Name and Phase (A/B) With the Corresponding LSP Wire Number PHASE PHASE CIRCUIT BREAKER CIRCUIT BREAKER LINE (circle LINE (circle LABEL/NAME LABEL/NAME one) one) Refrigerator CURRENT TRANSFORMER (CT) CURRENT TRANSFORMER (CT) Aux.
Page 22
STEP 14. Repeat Steps 10-13 Until All LSP Line # Wires Are Connected X 12 WARNING: HIGH VOLTAGE. Tools: Screwdriver, wire stripper and wire nuts NOTE: The LSP can connect to up to 12 single-pole (or six dual-pole) circuit breakers.
Page 23
Lumin Smart Panel INSTALLATION MANUAL STEP 15. Connect the 200A Current Transformers (CTs) Labeled “Line A/B CT” and Attach to The Electrical Panel’s Main Service Lines Phase A Phase B Line B Line A WARNING: HIGH VOLTAGE. NOTE: Connect the CTs labeled “Line A/B CT” to their corresponding LSP connector and then attach to the main service lines.
Page 24
STEP 16 (Optional). Connect the 2 Pair of CTs (if applicable) Labeled “Aux. A/B CT” and Attach to PV/Solar Generation Output Phase A Phase B Aux. A Aux. B WARNING: HIGH VOLTAGE. NOTE: Connect the CTs labeled “Aux. A/B CT” to their corresponding LSP connector and then attach to the solar output lines.
Page 25
Lumin Smart Panel INSTALLATION MANUAL STEP 17. Record The Line Name of the Corresponding Current Transformers (CTs) PHASE PHASE CIRCUIT BREAKER CIRCUIT BREAKER LINE (circle LINE (circle LABEL/NAME LABEL/NAME one) one) CURRENT TRANSFORMER (CT) CURRENT TRANSFORMER (CT) Aux. A/B CTs...
Page 26
STEP 18. Connect the LSP’s Grid Voltage Detector Wires to an Automatic Transfer Switch (ATS) or Main Distribution Panel Connect to Automatic Transfer Switch or Main Distribution Panel Grid Neutral Grid Line (white) (black) WARNING: HIGH VOLTAGE. Tools: Wire stripper and wire nuts NOTE: Extend the LSP wires labeled “Grid Neutral”...
Page 27
Lumin Smart Panel INSTALLATION MANUAL STEP 19. Replace the Electrical Panel Cover Surface-mounted installation Flush-mounted installation WARNING: HIGH VOLTAGE. Tools: Screwdriver NOTE: Please make any necessary drywall repairs (if applicable) and clean up the area around the circuit breaker panel once the LSP installation is completed. Make sure the...
LSP or go to https://luminsmart.com/accountsetup to establish a user account and set up the Lumin software for use with your LSP. You will need the completed LSP Circuit Label & CT Table to complete the account setup process.
Lumin Smart Panel INSTALLATION MANUAL PRODUCT SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS COMPATABILITY & COMPLIANCE Operating Temperature -20°C to 60°C (-4°F to Panel Any manufacturer 140°F) Enclosure Type Rittal KL 1511.510 Breakers Any manufacturer RoHS Compliant Compliance UL 916/61010 PHYSICAL SPECIFICATIONS INSTALLATION Dimensions 40.0cm x 40.0cm x 12.0cm...
(the “Lumin Service”). Use of the Lumin Service is subject to and governed by the terms of the Lumin Service User Agreement, a copy of which can be accessed at www.lumin.com/legal/useragreement.
Need help?
Do you have a question about the Smart Panel and is the answer not in the manual?