Fisher & Paykel PROFESSIONAL CPV3-488 Installation Manual

Gas rangetops
Hide thumbs Also See for PROFESSIONAL CPV3-488:

Advertisement

Quick Links

GAS RANGETOPS
PROFESSIONAL
CPV3-488, CPV3-485GD, CPV3-366, CPV3-304
INSTALLATION GUIDE
US CA

Advertisement

Table of Contents
loading

Summary of Contents for Fisher & Paykel PROFESSIONAL CPV3-488

  • Page 1 GAS RANGETOPS PROFESSIONAL CPV3-488, CPV3-485GD, CPV3-366, CPV3-304 INSTALLATION GUIDE US CA...
  • Page 2: Safety And Warnings

    SAFETY AND WARNINGS WARNING! WARNING! If the information in this guide is not Never operate the top surface cooking followed exactly, a fire or explosion section of this appliance unattended. may result causing property damage, • Failure to follow this warning statement personal injury or death.
  • Page 3 SAFETY AND WARNINGS Gas Requirements  WARNING! Be sure that the unit being installed is set up for the kind of gas being used. The gas rangetop is shipped from the factory set and adjusted for Natural Gas or LP (propane), Electric Shock Hazard depending on the specific model ordered.
  • Page 4: Components Required

    COMPONENTS REQUIRED PARTS TOOLS Keep all packing materials until the unit has been inspected. Not supplied Inspect the product to ensure there is no shipping damage. If any damage is detected contact the dealer or retailer you bought the product from to report the damage. Fisher &...
  • Page 5 PRODUCT DIMENSIONS 30" MODELS 30" MODELS PRODUCT DIMENSIONS A Overall height (excluding grates) 8 3/8 B Overall width 29 7/8 C Overall depth (excluding dials) 28 1/8 D Height of chassis 6 3/8 E Depth of chassis 24 3/16 F Height above countertop G Depth from chassis to front of control panel 26 11/16 PLAN...
  • Page 6 PRODUCT DIMENSIONS 36" MODELS 36" MODELS PRODUCT DIMENSIONS A Overall height (excluding grates) 8 3/8 B Overall width 35 7/8 C Overall depth (excluding dials) 28 1/8 D Height of chassis 6 3/8 E Depth of chassis 24 3/16 F Height above countertop G Depth from chassis to front of control panel 26 11/16 PLAN...
  • Page 7 PRODUCT DIMENSIONS 48" MODELS 48" MODELS PRODUCT DIMENSIONS A Overall height (excluding grates) 8 3/8 B Overall width 47 7/8 1216 C Overall depth (excluding dials) 28 1/8 D Height of chassis 6 3/8 E Depth of chassis 24 3/16 F Height above countertop G Depth from chassis to front of control panel 26 11/16...
  • Page 8: Cabinetry Dimensions

    CABINETRY DIMENSIONS 30" CABINETRY 36" CABINETRY 30" MODELS 36" MODELS CABINETRY DIMENSIONS CABINETRY DIMENSIONS INCHES INCHES A Height A Max. height B Depth B Depth Flush with counter 26 5/8 Flush with counter 26 5/8 Projecting control panel 24 3/16 Projecting control panel 24 3/16 C Width...
  • Page 9 CABINETRY DIMENSIONS 48" CABINETRY CLEARANCES The below clearances apply to both wall and island installations for all models. Ensure the cook surface sits flush or above the adjacent countertop and any openings behind or under the rangetop are sealed. Flow of combustion and ventilation air must not be obstructed. Ensure the cooktop is adequately supported from the bottom.
  • Page 10: Ventilation Requirements

    VENTILATION REQUIREMENTS Ventilation hoods and blowers are designed for use with single wall ducting, however some local building codes or inspectors may require double wall ducting and/or a damper. Consult local building codes and/or agencies, before installing to ensure local requirements are met. Semi-rigid ducting is recommended for maximum effectiveness. Hood blower speeds should be variable to reduce noise and loss of household air.
  • Page 11: Electrical Requirements

    ELECTRICAL REQUIREMENTS The electrical supply must be a correctly polarized, grounded 120 V AC, 60 Hz, single phase circuit suitable for the maximum current draw of the model, as detailed in the table below. Please verify your model’s current draw by checking the rating label on the rangetop. Required grounding method This appliance is factory equipped with a power supply cord with a three-prong grounding plug (with polarized parallel blades).
  • Page 12: Gas Requirements

    GAS REQUIREMENTS Verify the type of gas supplied to the location. The rangetop is shipped from the factory set up and adjusted for Natural Gas or LP, depending on the specific model ordered. If the rangetop is not set for the gas supplied at the site, return to the dealer. Pressure testing at test pressures in excess of 1/2 psig (3.5 kPa.): the rangetop and its individual shut-off valve must be disconnected from the gas supply piping system Pressure testing at test pressures equal to or less than 1/2 psig (3.5 kPa.): The rangetop must be isolated from the building’s gas supply piping system by closing its individual manual shut-off valve LP GAS CONNECTION...
  • Page 13: Cooktop Burners

    COOKTOP BURNERS LEAK TESTING lifting off yellow tip stable blue flame Ensure all dials are set to before connecting rangetop to gas supply. To check that the ignition system operates correctly, light each burner by itself, then all After final gas connection is made, turn gas supply on and test all connections in gas supply burners in combination.
  • Page 14: Final Checklist

    FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER GENERAL … … Specified clearance maintained. Connection: 1/2 NPT with a minimum 5/8" diameter flex line. Site gas supply is compatible with cooktop model, and sufficient pressure is available … Backguard installed if clearance to combustibles behind unit is less than 6" (152mm). …...
  • Page 16 FISHERPAYKEL.COM © Fisher & Paykel Appliances 2020. All rights reserved. The models shown in this guide may not be available in all markets and are subject to change at any time. The product specifications in this guide apply to the specific products and models described at the date of issue.

Table of Contents