Error display of additional units on CAN bus (only with FPC)

15.2
Those error numbers consist of 4 digits as follows:
• Digits 1 + 2 indicate the reason of the error
• Digits 3 + 4 specify the name of the unit
Example: error number 1616 means that sensor AKI 1 does
not have any teaching parameter and a teach-in run has to
be performed.
Digits
Display text
1+2 3+4
11
--
CAN node not found
12
--
CAN connect.(SEND)
13
--
CAN connect.(RECV)
14
--
EEPROM defective
15
--
EEPROM void
16
--
No running parameter
17
--
HW defective
18
--
Redundancy path
19
--
Background check
20
--
Software error
21
--
CAN connection blocked
22
--
SAFETY_LEVEL
23
--
24
--
--
08 SENS SI 1
--
09 SENS SI 2
10 SENS SA 1
--
11 SENS SA 2
--
12 SENS SL
--
--
13 SENS SR
--
16 SENS AKI 1
--
17 SENS AKI 2
--
18 SENS AKA 1
--
19 SENS AKA 2
--
32 FPC
--
--
Comments
CAN connection interrupted
Send CAN connection
CAN connection received
EEPROM faulty
EEPROM empty
No teaching parameters available
Hardware faulty
Redundant radar sensor faulty
The background is not appropriate for this sensor or installation is too high, or
weak IR light intensity
An error has arisen in the software of the external unit.
The anti-burglary protection has responded and locked the CAN connection to the
external unit.
The AKI sensor is not allowed for the security level required by the RED door
controller.
SI 1 Presence detector inside 1
SI 2 Presence detector inside 2
SA 1 Presence detector outside 1
SA 2 Presence detector outside 2
SL Side surveillance left
SR Side surveillance right
AKI 1 Actuating device inside 1
AKI 2 Actuating device inside 2
AKA 1 Actuating device outside 1
AKA 2 Actuating device outside 2
Possible troubleshooting
Control connection
Control connection
Control connection
Load factory settings. Replace unit
Load factory settings. Replace unit
Perform teach-in run
Replace unit
Reset or restart control unit
Check/reduce installation height, disable function. Error in IR part, replace unit.
Carry out a new start. If the error is still active after this, the unit must be replaced.
If the door is locked, no external units, such as BDE-D, FPC and FEMx, may be connected to
the CAN bus. Unlock door, briefly press MFT key or actuate the EMERGENCY STOP switch.
Replace sensor with an appropriate redundant sensor.
Service unit FPC902