Download Print this page
CEECO WPP-531-D-RP-ADA-STROBE Service Manual

CEECO WPP-531-D-RP-ADA-STROBE Service Manual

Weatherproof emergency telephone with remote programming and optional strobe feature

Advertisement

Quick Links

MODEL WPP-531-D(EMER)-RP-ADA-STROBE
WEATHERPROOF EMERGENCY TELEPHONE WITH REMOTE
PROGRAMMING AND OPTIONAL STROBE FEATURE
EQUIPPED WITH SPK1.07UNVLr1 FIRMWARE
Communication Equipment
& Engineering Company
SERVICE MANUAL
WPP-531-D(EMER)-RP-SPK1.07UNVLr1-ADA-STROBE-ISSUE4.0
FOR
Serving the Telephone Industry Since 1930
519 W South Park Street
Okeechobee, FL 34972
Voice: 863-357-0798
Fax: 863-357-0006

Advertisement

loading
Need help?

Need help?

Do you have a question about the WPP-531-D-RP-ADA-STROBE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CEECO WPP-531-D-RP-ADA-STROBE

  • Page 1 WPP-531-D(EMER)-RP-SPK1.07UNVLr1-ADA-STROBE-ISSUE4.0 SERVICE MANUAL MODEL WPP-531-D(EMER)-RP-ADA-STROBE WEATHERPROOF EMERGENCY TELEPHONE WITH REMOTE PROGRAMMING AND OPTIONAL STROBE FEATURE EQUIPPED WITH SPK1.07UNVLr1 FIRMWARE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering Company Okeechobee, FL 34972 Voice: 863-357-0798 Fax: 863-357-0006...
  • Page 2 Issue 4.0 IMPORTANT INFORMATION CUSTOMER Please fill in before you continue. The following information is necessary when calling CEECO for assistance. MODEL NUMBER MODEL WPP-531-D(EMER)-RP-ADA-STROBE, EQUIPPED WITH SPK1.07UNVLr1 FIRMWARE. SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you, please have this information available when calling for technical support.
  • Page 3: Table Of Contents

    SPECIFICATIONS ...................... 15 PARTS LIST......................... 16 10.0 FCC NOTICE ....................... 17 11.0 REPAIR AND RETURN INFORMATION .............. 18 12.0 WARRANTY POLICY....................19 13.0 TELEPHONE LINE WIRING DIAGRAM ............. 19 14.0 AUTO-ANSWER DIAGRAM..................20 CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 4 Issue 4.0 15.0 AC LINE DIAGRAM....................20 CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 5: Introduction

    Start/Press-To-Stop (CALL) button for the initiation and termination of phone calls. 2.02 The CEECO telephone is equipped with an auto-answer feature to allow remote programming of features, and remote monitoring for “listening” to the room or area in which the CEECO telephone is installed.
  • Page 6: Programming

    Placing this switch in the “ON” position will set the phone so that it cannot be hung up locally after placing a call. Instead, it must hang up by way of automatic call disconnect (timer) or wink detection. CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 7: Programming Continued

    Digit 6 in the next section of programming-3.9. Example: Enter #197771313. During programming in the next section (3.9), enter a “2” for Digit 6. This will program the phone to automatically dial the CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 8: Programming Continued

    Always 0 for this model Digit 9 Do not dial PBX access number stored in location #02. Dial PBX number stored in location #02. Digit 10 No wink detect. Length of the wink detect. CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 9 Issue 4.0 (1=50ms incremental to 450 ms. 5 is recommended). CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 10: Programming Continued

    As depicted in the diagram, the mini-jumper may be placed across any choice of pin pairs 1-9; thus causing the telephone to automatically answer after the selected number of rings (1-9 rings). Make a selection and place the mini- jumper accordingly. CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 11: Programming Continued

    Place a call from another telephone to the CEECO telephone. The CEECO telephone will automatically answer itself after the number of rings selected in section 3.12. The CEECO telephone then sends two tones as a prompt for the security code.
  • Page 12: Remote Monitoring

    Place a call to the CEECO telephone from another phone. The CEECO telephone will answer itself after the number of rings programmed in section 3.12. The CEECO telephone sends out two tones as a prompt for the next step. 5.03 Using the calling telephone, dial # * which will turn on the microphone for remote monitoring of the area of the CEECO telephone.
  • Page 13: Installation Continued

    3.09, Digit 6). After the called party answers, a normal speakerphone conversation should be allowed. If the auto-dial number does not work, please repeat sections 3.02, 3.03, 3.04, 3.07, 3.08, and 3.11 only. If trouble is still experienced, please refer to section 11.02. CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 14: Testing/Operation Continued

    Testing is now complete. If any trouble was encountered that has not been remedied, please refer to section 11.02 of this manual, otherwise the phone is ready for operation. NOTE: CEECO can not be responsible for the called party's response regarding ADA features and compliance, and emergency response. 7.07 Carefully return the telephone assembly to the weatherproof housing.
  • Page 15: Specifications

    WEIGHT: Approximately 16 Pounds DIMENSIONS: 9" Wide x 13" High x 8.5" Deep STROBE LIGHT: 120VAC 50/60 Hz 4” Wide(Dia.) x 5” High TYPE JACK: RJ11C U.L. LISTED NO.: 6OF5 FCC REGISTRATION BW8USA-73021-MT-E CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 16: Parts List

    QUANTITY PART NUMBER DESCRIPTION 331-006 OUTER COVER SECURITY SCREW 301-018 MODULAR LINE CORD 301-054UL MODULAR CONNECTOR (RJ11C) 700-008 KEYPAD CABLE 660-000 CEECO SPEAKER BOARD 660-650 CEECO AUTO-ANSWER PCB 705-110 CONNECTORIZED KEYPAD 6020 MOMENTARY PANEL SWITCH 14024 SPEAKER 14067 MICROPHONE 331-005...
  • Page 17: Fcc Notice

    FCC registration number and ringer equivalence number. These numbers are listed in Section 8.0. The FCC further requires that you notify your local telephone company when permanently disconnecting this telephone. CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 18: Repair And Return Information

    11.03 NON-WARRANTY REPAIR CEECO will repair equipment out of warranty for a set charge, plus parts. The customer must pay the shipping costs in both directions. 11.04 RETURN FOR CREDIT Material may be returned for credit only with prior approval. Material authorized for return is subject to a 20% restocking charge based on the manufacturer’s list price.
  • Page 19: Warranty Policy

    Printed circuit boards should not be repaired in the field. If a unit is found to be faulty, replace it with another unit and return the faulty unit to CEECO for repair. Modifications by anyone other than CEECO will void the warranty.
  • Page 20: Auto-Answer Diagram

    15.0 A/C LINE DIAGRAM Screw Driver AC Wire • Insert screw driver through hole in plastic protector. • Insert wires under plastic protector and onto terminals. • Non-polarity sensitive. Positive and Negative on either post. CEECO Communication Equipment & Engineering Company PROPRIETARY...

This manual is also suitable for:

Wpp-531-demer-rp-ada-strobe