KBi KSM Installation & Operation Manual page 7

Kapower starting module
Table of Contents

Advertisement

Specifications
Electrical Characteristics
Operating Voltage Window
Maximum Voltage
Minimum Voltage
Internal Resistance
Capacitance
Energy Stored within Operating
Voltage Window
Energy Stored at Max Voltage
Maximum Power
Leakage Current at Max Voltage
Operating Conditions
Operating Temperature Range
Cycle Life
Dimensions and Weight
Length x Width x Height
Weight
The KAPower KSM is a product of high electric power. Avoid shorting module
terminals. A brief short circuit will not cause product failure, however, it may result in
burning or igniting of combustible materials adjacent to the point of short circuit.
The KAPower module is polarity sensitive. Polarity shall be strictly observed when
Table 1: Specifications
12V
6 Cell Unit
10 Cell Unit
7 – 14.5V
18V
0V
0.0011 ohms
0.0008 ohms
525 F
42.3 kJ
85.1 kJ
47 kW
4.5 mA
-40° – 185°F
-40° – 185°F
(-40° – 85°C)
(-40° – 85°C)
>1,000,000
>1,000,000
14.79" x 7.75" x 8"
19.44" x 7.75" x 8"
22 lb.
WARNING
CAUTION
connecting the KAPower module.
7
12V
24V
10 Cell Unit
7 – 14.5V
8 – 29V
18V
30V
0V
0V
0.0019 ohms
1250 F
315 F
101.6 kJ
122.4 kJ
141.8 kJ
141.8 kJ
112 kW
112 kW
4.5 mA
4.5 mA
-40° – 185°F
(-40° – 85°C)
>1,000,000
19.44" x 7.75" x 8"
32.5 lb.
32.5 lb.
24V
12 Cell Unit
8 – 29V
33V
0V
0.0022 ohms
263 F
102 kJ
142.9 kJ
94 kW
4.5 mA
-40° – 185°F
(-40° – 85°C)
>1,000,000
19.44" x 7.75" x 8"
34.5 lb.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mksm