OST iConverter 5 Port GM4 Quick Start Manual

OST iConverter 5 Port GM4 Quick Start Manual

Network interface devices

Advertisement

Quick Links

iConverter
5 Port GM4
®
Network Interface Devices
Quick Start Guide
38 Tesla, Irvine, CA 92618 USA
Phone: (949) 250-6510; Fax: (949) 250-6514
General and Copyright Notice
This publication is protected by U.S. and international copyright laws. All rights
reserved. The whole or any part of this publication may not be reproduced, stored
in a retrieval system, translated, transcribed, or transmitted, in any form, or by
any means, manual, electric, electronic, electromagnetic, mechanical, chemical,
optical or otherwise, without prior explicit written permission of Omnitron Systems
Technology, Inc.
The following trademarks are owned by Omnitron Systems Technology, Inc.:
FlexPoint
, FlexSwitch
, HybridNID
TM
TM
OmniLight
, OmniConverter
, RuggedNet
®
®
OST
and the Omnitron logo.
TM
All other company or product names may be trademarks of their respective owners.
The information contained in this publication is subject to change without notice.
Omnitron Systems Technology, Inc. is not responsible for any inadvertent errors.
Warranty
This network product and the included AC/DC power adapter are warranted to the
original purchaser (Buyer) against defects in material and workmanship for a period
of two (2) years from the date of shipment. The warranty for the network product can
be extended to three (3) years by registering the product at www.omnitron-systems.
com/support within ninety (90) days from the date of shipment. During the warranty
period, Omnitron will, at its option, repair or replace a product which is proven to be
defective with the same product or with a product with at least the same functionality.
For warranty service, the product must be sent to an Omnitron designated facility,
at Buyer's expense. Omnitron will pay the shipping charge to return the product
to Buyer's designated US address using Omnitron's standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to product malfunctions resulting from
improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-
supplied equipment, Buyer-supplied interfacing, unauthorized modifications or
tampering with equipment (including removal of equipment cover by personnel not
specifically authorized and certified by Omnitron), or misuse, or operating outside
the environmental specification of the product (including but not limited to voltage,
ambient temperature, radiation, unusual dust, etc.), or improper site preparation
or maintenance.
No other warranty is expressed or implied. Omnitron specifically disclaims the implied
warranties of merchantability and fitness for any particular purpose.
The remedies provided herein are the Buyer's sole and exclusive remedies. Omnitron
shall not be liable for any direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal theory.
, iConverter
, miConverter
, NetOutlook
®
®
TM
, Omnitron Systems Technology, Inc.
®
Page 2
,
®
,
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iConverter 5 Port GM4 and is the answer not in the manual?

Questions and answers

Summary of Contents for OST iConverter 5 Port GM4

  • Page 1 General and Copyright Notice This publication is protected by U.S. and international copyright laws. All rights reserved. The whole or any part of this publication may not be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form, or by any means, manual, electric, electronic, electromagnetic, mechanical, chemical, optical or otherwise, without prior explicit written permission of Omnitron Systems Technology, Inc.
  • Page 2: Product Overview

    iConverter ® 5 Port GM4 Environmental Notices The equipment covered by this manual must be disposed of or recycled in Quick Start Guide accordance with the Waste Electrical and Electronic Equipment Directive (WEEE Product Overview Directive) of the European Community directive 2012/19/EU on waste electrical and electronic equipment (WEEE) which, together with the RoHS Directive 2015/863/ The iConverter GM4 is an intelligent Network Interface Device (NID), that delivers EU, for electrical and electronic equipment sold in the EU after July 2019.
  • Page 3: Serial Console Port

    Serial Console Port 1) Configure DIP-switches The module can be configured by attaching the serial port to a DB-9 serial (RS-232) The GM4 has two banks of DIP-switches. The location of the DIP-switches is equipped computer with terminal emulation software such as ProComm or Putty. The illustrated below.
  • Page 4: Installing The Module

    2) Installing the Module Wall Mounting The wall mounting height of the module should be less than or equal to 2 meters (6.6 feet) from the floor. Use the four mounting holes on the module to secure the module to the wall. The module can accommodate #6 screws (not included). Installation of the module should be such that the air flow in the front, back, side and top vents of the switch are not compromised or restricted.
  • Page 5 3) Apply Power AC Power Secure the ground wire to the ground screw located on the back of the module. Route the power cord through the provided strain relief for additional support and connect the barrel connector at the end of the wire on the AC/DC adapter to the barrel connector on the module.
  • Page 6: Connect Cables

    4) Connect Cables When using SFP models, insert the SFP fiber transceiver into the SFP receptacle on the front of the module (see the SFP Data Sheet 091-17000-001 for supported Fast/Gigabit transceivers). NOTE: The release latch of the SFP fiber transceiver must be in the closed (up) position before insertion.
  • Page 7: Verify Operation

    5) Verify Operation LED Legend/State Link Speed Once the module has been installed and the DIP-switches have been configured, “1000” “100” verify the module is operational by viewing the status of the LED indicators. Port not linked The Power LEDs indicate the module is receiving power from the external power Port linked at 100Mbps source.
  • Page 8: Customer Support Information

    Customer Support Information IEEE 802.1Q, 802.1ad, 802.1ax, 802.1p, 802.3, 802.3ad, 802.3ah, 802.1ag, 1588v2 If you encounter problems while installing this product, contact Omnitron Technical RFC 2819 (RMON), 2863 (IF-MIB), 2131 (DHCP), 2544, 5357 Standard Compliances Support: ITU-T G.8031, G.8032, G.8262, Y.1731, Y.1564 MEF 9, 14, 21, 30, 31, Carrier Ethernet 2.0 Regulatory Compliances UL, CE, FCC Class A, NEBS Level 3...

Table of Contents