INSTALLATION INSTRUCTIONS Blitzductor
Installation / Montage
Blitzductor BXT BAS EX
BXT ML4 BD EX 24, BXT ML4 BC EX 24
IECE DEK 11.0078X
Ex ia [ia Ga] IIC T4/T5/T6 Gb
Ex ib IIC T4/T5/T6 Gb
KEMA 06 ATEX 0274 X
OCP 0004
II 2 (1) G Ex ia [ia Ga] IIC T4/T5/T6 Gb
Certificado N.º: TUV 17.0697X
II 2 G Ex ib IIC T4/T5/T6 Gb
Ex ia [ia Ga] IIC T6...T4 Gb
FISCO
Ex ib IIC T6...T4 Gb
Standards:
Para conexão para circuitos
for ATEX: EN 60079- 0: 2012
intrinsecamente:
EN 60079-11: 2012
U
= 30 V
i
for IECEx: IEC 60079-0:
2011
I
= 500 mA
i
IEC 60079-11: 2011
P
= indeterminada
i
IEC 60079-26: 2006
C
= desprezível
i
L
= desprezível
i
Connection with intrinsically
safe circuits with:
Ou para conexão para circuitos FISCO
U
= 30 V
U
= 17,5 V
i
i
I
= 500 mA
I
= 380 mA
i
i
P
= any
P
= 5,32 W
i
i
C
negligibly small
C
= desprezível
i
i
L
negligibly smal
L
= desprezível
i
i
Special conditions for safe use
Faixa de temperatura ambiente:
The dielectric strength of at least 500 V of
-40 °C ≤ Ta ≤ +55 °C – para T6
the intrinsically safe circuits of the
-40 °C ≤ Ta ≤ +75 °C – para T5
Blitzdutor series BXT is limited only by the
-40 °C ≤ Ta ≤ +80 °C – para T4
overvoltage protection.
Normas Técnicas / Regulamento:
Ambient temperature range:
ABNT NBR IEC 60079-0:2013
ABNT NBR IEC 60079-11:2013
-40°C... +55°C for temperature class T6
ABNT NBR IEC 60079-26:2016
-40°C... +75°C for temperature class T5
Portaria INMETRO n° 179 de 18/05/2010
-40°C... +80°C for temperature class T4
0.08 - 2.5 mm²
AWG 28 -14
7 mm
≤ 0.4
≤ 3.5
Nm
in-lbs
2.5
0.4
mm
mm
Application / Anwendung
Fieldbus FISCO
Power supply
1
U o ≤ 17.5 V,
I o ≤ 380 mA
Field device
2
U i ≤ 17.5 V, I i ≤ 380 mA,
P i ≤ 5.32 W, C i negligibly small,
L i negligibly small
* Intrinsically safe circuits
see Control drawing on page 2
Power supply (Fisco); Segment
1
2
3
Blitzductor BXT ML4 BD EX 24
4
Field device (Fisco)
Terminator
BXT ML4 BD/BC EX 24
®
I
L
protected
≥ 4 mm²
≤ AWG 10
Segment
1
Segment
1
3
3
/
1
1
protected
4
4
1
BXT ML4 BD EX 24, 920 381
1
protected
2
3
4
3
protected
protected
4
1559 / 05.17 / 3009200
2
4
1 2 3 4
4´ 3´ 2´ 1´
1
1
3
BXT BAS EX
BXT ML4...
2
2
4
1 2 3 4
4´ 3´ 2´ 1´
1
3
BXT BAS EX
BXT ML4 BC EX 24, 920 384
1
2
3
4
Note:
Use Test Device
not in
hazardous area!
© COPYRIGHT 2017 DEHN + SÖHNE / protected by ISO 16016
www.dehn.de
www. dehn-international.com

Advertisement

loading

Summary of Contents for dehn Blitzductor BXT ML4 BD EX 24

  • Page 1 Control drawing on page 2 Use Test Device Power supply (Fisco); Segment not in www.dehn.de Blitzductor BXT ML4 BD EX 24 hazardous area! www. dehn-international.com protected protected Field device (Fisco) Terminator © COPYRIGHT 2017 DEHN + SÖHNE / protected by ISO 16016...
  • Page 2 EN 61643-21:2001 + DS-Y-06-12 18.01.2016 A1:2009 + A2:2013 A1:2009 + A2:2013 CE_BXT_ML4_BC_EX_24 07.03.2016 1 of 2 CE_BXT_ML4_BD_EX_24 07.03.2016 1 of 2 CE_BXT_ML4_BD_EX_24 07.03.2016 2 of 2 CE_BXT_ML4_BC_EX_24 07.03.2016 2 of 2 © COPYRIGHT 2017 DEHN + SÖHNE / protected by ISO 16016...
  • Page 3 1559 / 05.17 / 3009200 Überspannungsschutz DEHN + SÖHNE Hans-Dehn-Str. 1 Tel. +49 9181 906-0 IEC 60417-6182: Blitzschutz/Erdung GmbH + Co.KG. Postfach 1640 www.dehn-international.com Installation, Arbeitsschutz 92306 Neumarkt electrotechnical expertise DEHN schützt. ® Germany Instruções de Segurança Informazioni di sicurezza Indicaciones de seguridad Consignes de sécurité...
  • Page 4 1559 / 05.17 / 3009200 Überspannungsschutz DEHN + SÖHNE Hans-Dehn-Str. 1 Tel. +49 9181 906-0 IEC 60417-6182: Blitzschutz/Erdung GmbH + Co.KG. Postfach 1640 www.dehn-international.com Installation, Arbeitsschutz 92306 Neumarkt electrotechnical expertise DEHN schützt. ® Germany Υποδείξει ασφαλεία Instrukcje bezpieczeństwa Bezpečnostní pokyny Güvenlik uyarıları...

This manual is also suitable for:

Blitzductor bxt ml4 bc ex 24