Download Print this page

External Modules - Cisco 1000 Series Manual

Install and upgrade internal modules and field replaceable units

Advertisement

External Modules

Step 1
Read the Safety Warnings and disconnect the power supply before you perform any module replacement.
Step 2
Confirm the router is turned off and disconnected from the power supply.
Step 3
Disconnect all port cables connected to the router. Ensure that you do not work on the router with cables still attached to
the router in the event of lightning or surges.
Step 4
Place the chassis on a flat surface.
Step 5
Align hooks on the cover to slots on the chassis base and lower the cover onto chassis base.
Step 6
Slide the cover from the I/O side to the bezel side
Step 7
Install the fourteen screws on both sides of the chassis. Torque to 6-8 in-lbs.
External Modules
The Cisco 1100 Series Integrated Services Routers have external modules and field-replaceable units (FRUs)
that can be quickly and easily removed and replaced without having to send the entire router for repair.
This section describes how to install external modules and FRUs in the Cisco 1100 Series ISRs. The information
is contained in the following sections:
Warning
Only trained and qualified personnel should be allowed to install, replace or service this equipment. Statement
1030.
Locate External Slots for Modules
This section describes the locations of external modules on the router motherboard.
Install and Upgrade Internal Modules and Field Replaceable Units
4
Install and Upgrade Internal Modules and Field Replaceable Units

Advertisement

loading