Page 1
Test Report: CE03111004-A CE EMC TEST REPORT according to EN 301 489-1 V1.4.1 (2002-08) and EN 301 489-17 V1.2.1 (2002-08) Applicant TRENDware International, Inc. Address 3135 Kashiwa Street, Torrance, CA90505 U.S.A. Equipment Cable/DSL 802.11g 54Mbps Wireless Router Model No. TEW-431BRP...
Test Report: CE03111004-A Contents CERTIFICATE OF COMPLIANCE ........................4 Definition..............................5 Test Distance ...............................6 2.1. Summary of Test Results ......................6 Test of Conducted Powerline........................7 3.1. Test Procedures .........................7 3.2. Typical Test Setup Layout of Conducted Powerline..............8 3.3. Conducted Emission Requirement ....................8 Test of Radiated Emission...........................9 4.1.
Page 3
Test Report: CE03111004-A 20.2. Photographs of Radiated Emission Test Configuration ............47 Harmonics Test ..........................48 Voltage Fluctuations Test........................49 22.1. TEST EQUIPMENT SETTINGS....................49 22.2. Photographs of Harmonics test, Voltage Fluctuation and Flicker test ........50 Electrostatic Discharge Immunity Test (ESD) ...................51 23.1. Test Severity Levels .........................51 23.2.
Test Report: CE03111004-A CERTIFICATE OF COMPLIANCE according to EN 301 489-1 V1.4.1 (2002-08) and EN 301 489-17 V1.2.1 (2002-08) Applicant TRENDware International, Inc. Address 3135 Kashiwa Street, Torrance, CA90505 U.S.A. Equipment Cable/DSL 802.11g 54Mbps Wireless Router Model No. TEW-431BRP I HEREBY CERTIFY THAT : The measurements shown in this test report were made in accordance with the procedures given in EUROPEAN COUNCIL DIRECTIVE 99/5/EC.
Test Report: CE03111004-A 1. Definition Unintentional radiator: A device that intentionally generates and radio frequency energy for use within the device, or that sends radio frequency signals by conduction to associated equipment via connecting wiring, but which is not intended to emit RF energy by radiation or induction. Class A Digital Device: A digital device Which is marketed for use in commercial or business environment;...
Test Report: CE03111004-A 2. Test Distance a. The test distance of radiated emission test from antenna to EUT is 10 M. b. The test distance of radio frequency electromagnetic field immunity test from antenna to EUT is 3 M. 2.1. Summary of Test Results 19.1.1 Emission Tests Test Measurement...
Test Report: CE03111004-A 3. Test of Conducted Powerline Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 kHz and return leads The EUT was placed of the EUT according to the methods defined in European Standard EN 301 489-17. on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown in section 2.2.
Test Report: CE03111004-A 3.2. Typical Test Setup Layout of Conducted Powerline 10cm 80cm 80cm 80cm 40cm LISN LISN 40cm 3.3. Conducted Emission Requirement The equipment under test EUT)shall meet the limits in table 1and 3 or 2 and 4,as applicable, including the average limit and the quasi-peak limit when using,repectively, an average detector receiver and quasi-peak detector receiver and measured in accordance with the methods described in clause 9.
Test Report: CE03111004-A 4. Test of Radiated Emission Radiated emissions from 30 MHz to 1000 MHz were measured with a bandwidth of 120 kHz according to The EUT was placed on a nonmetallic the methods defines in European Standard EN 301 489-17. stand in the open-field site, 0.8 meter above the ground plane, as shown in section 3.2.
Test Report: CE03111004-A 4.2. Typical Test Setup Layout of Radiated Emission Antenna Equipment under Test Test distance 0.8M Turn Table Ground Plane Receiver 4.3. Radiated Emission Requirement The EUT shall meet limits of tables as below when measured at the measuring distance R in accordance with the methods described in clause 10.
Test Report: CE03111004-A 5. Harmonics Test 5.1. STANDARD Product Standard : EN 61000-3-2:2000 5.2. Test Procedure As specified on clause 7 and figure Z1 of EN 61000-3-2:2000, the limits are not specified for equipment with a rated power of 75W or less. The EUT meets the above condition, so it conforms to EN 61000-3-2.
Test Report: CE03111004-A 6. Voltage Fluctuations Test 6.1. STANDARD Product Standard : EN 61000-3-3:1995/A1:2001 6.2. Test Procedure The equipment shall be tested under the conditions of Clause 5. The total impedance of the test circuit, excluding the appliance under test, but including the internal impedance of the supply source, shall be equal to the reference impedance.
Test Report: CE03111004-A 7. Test setup (ESD) VCP: 0.5x0.5 m TABLE SIZE 470K ohm 1.6LX0.8WX0.5H m 470K ohm 10cm 10cm 470K ohm 470K ohm 1.6mx0.8m The test setup consists of the test generator, EUT and auxiliary instrumentation necessary to perform DIRECT and INDIRECT application of discharges to the EUT as applicable, in the follow manner : a.
Test Report: CE03111004-A 7.2. Test Procedure a. In the case of air discharge testing the climatic conditions shall be within the following ranges: - ambient temperature: 15 to 35 ; ℃ ℃ - relative humidity : 30% to 60%; - atmospheric pressure : 68 KPa (680 mbar) to 106 KPa (1060 mbar). b.
Test Report: CE03111004-A 8. Test Procedure (RS) a. The equipment to be tested is placed in the center of the enclosure on a wooden table. The equipment is then connected to power and signal leads according to pertinent installation instructions. b.
Test Report: CE03111004-A 9. Test on Power Line (EFT) a. The EFT/B-generator was located on the GRP.. The length from the EFT/B-generator to the EUT as not exceed 1 m. b. The EFT/B-generator provides the ability to apply the test voltage in a non-symmetrical condition to the power supply input terminals of the EUT..
Test Report: CE03111004-A 10. Test Procedure (Surge) Climatic conditions The climatic conditions shall comply with the following requirements : ambient temperature : 15 to 35 ℃ ℃ relative humidity : 10 % to 75 % atmospheric pressure : 86 kPa to 106 kPa ( 860 mbar to 1060 mbar ) Electromagnetic conditions the electromagnetic environment of the laboratory shall not influence the test results.
Test Report: CE03111004-A 11. Test Procedure (CS) The EUT shall be operated within its intended climatic conditions. The temperature and relative humidity should be recorded. This test method test can be performed without using a sell shielded enclosure. This is because the disturbance levels applied and the geometry of the setups are not likely to radiated a high amount of energy, especially at the lower frequencies.
Test Report: CE03111004-A 12. Testing Requirement and Procedure (DIP) The test was based on IEC 61000-4-11 (1994) 12.1. Test Conditions 1. Source voltage and frequency : 230V / 50Hz, Single phase. 2. Test of interval : 10 sec. 3. Level and duration : Sequency of 3 dips/interrupts. 4.
Test Report: CE03111004-A 13. Notice for Class A Product This Notice is for class A product only. If the Equipment under Test is a class B product, this notice should be disregarded. Class A ITE is a category of all other ITE which satisfies the class A ITE limits but not the class B ITE limits.
15.1. History of this test report The Model No. TEW-431BRP (Report No:CE03111004-A) is the same and it only differs from the outside cosmetic. The functions and specifications are the same. Issued date: Dec. 16, 2003...
16.2. Description of Test System For Conducted Emission Test and Radiated Emission Test Product Manufacturer Model No. Serial No. I/O Cable Wireless Non-shielded, 1.2m TRENDware TEW-431BRP Broadband Router Non-shielded, 2.5m Printer EPSON Stylus photo 700 shielded, 1.2m Non-shielded, 2.5m Notebook PC Comoaq...
Test Report: CE03111004-A 17. Test Software During testing, “Ping.exe” under WIN 2000 was executed to link with the remote workstation to receive and transmit data by UTP cable. Issued date: Dec. 16, 2003 23 of 23 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Test Report: CE03111004-A 18. General Information of Test ELECTRONICS TESTING CENTER, Taiwan Test Site No. 34, Lin 5, Ding Fu Tdun, Linkou Hsiang, Taipei, Taiwan, R.O.C. Test Voltage : 230V/ 50Hz EMI Test (conduction and radiation) : EN 301 489-1 V.1.4.1 (2002-08) EN 301 489-17 V.1.2.1 (2002-08) Harmonics Test : European Standard EN 61000-3-2.
Test Report: CE03111004-A 18.1. Description of Major Test Instruments (For Conducted) Test Equipment Calibration Date Recommended Recal. Date Shielded Room\ Riken\--- N.C.R. N.C.R. EMI test receiver\R&S\ESCS30 Aug. 10, 2003 Aug. 09, 2004 L.I.S.N.\EMCO\ESH2-Z5 Sep. 22, 2003 Sep. 21, 2004 Monitor\IBM \E54 N.C.R.
Test Report: CE03111004-A 19. Test Result of AC Powerline Conducted Emission 19.1. Test Mode 1 (CH 01b @ 11Mbps Bit-Rate) Relative Humidity: 70 % Temperature: 24°C Test Date: Nov. 28, 2003 Power Supply System: AC Power: 230Vac 50Hz Test Set-up: Table-top Equipment All emissions not reported here are more than 10 dB below the prescribed limit.
Page 27
Test Report: CE03111004-A Issued date: Dec. 16, 2003 27 of 27 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Page 28
Test Report: CE03111004-A Issued date: Dec. 16, 2003 28 of 28 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Page 29
Test Report: CE03111004-A 19.1.1 Test Mode 2 (CH 07b @ 11Mbps Bit-Rate) Relative Humidity: 70 % Temperature: 24°C Test Date: Nov. 28, 2003 Power Supply System: AC Power: 230Vac 50Hz Test Set-up: Table-top Equipment All emissions not reported here are more than 10 dB below the prescribed limit. ■...
Page 30
Test Report: CE03111004-A Issued date: Dec. 16, 2003 30 of 30 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Page 31
Test Report: CE03111004-A Issued date: Dec. 16, 2003 31 of 31 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Page 32
Test Report: CE03111004-A 19.1.2 Test Mode 3 (CH 13b@ 11Mbps Bit-Rate) Relative Humidity: 70 % Temperature: 24°C Test Date: Nov. 28, 2003 Power Supply System: AC Power: 230Vac 50Hz Test Set-up: Table-top Equipment All emissions not reported here are more than 10 dB below the prescribed limit. ■...
Page 33
Test Report: CE03111004-A Issued date: Dec. 16, 2003 33 of 33 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Page 34
Test Report: CE03111004-A Issued date: Dec. 16, 2003 34 of 34 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Page 35
Test Report: CE03111004-A 19.1.3 Test Mode 4 (CH 01g@ 54Mbps Bit-Rate) Relative Humidity: 70 % Temperature: 24°C Test Date: Nov. 28, 2003 Power Supply System: AC Power: 230Vac 50Hz Test Set-up: Table-top Equipment All emissions not reported here are more than 10 dB below the prescribed limit. ■...
Page 36
Test Report: CE03111004-A Issued date: Dec. 16, 2003 36 of 36 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Page 37
Test Report: CE03111004-A Issued date: Dec. 16, 2003 37 of 37 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Page 38
Test Report: CE03111004-A 19.1.4 Test Mode 5 (CH 07g @ 54Mbps Bit - Rate) Relative Humidity: 70 % Temperature: 24°C Test Date: Nov. 28, 2003 Power Supply System: AC Power: 230Vac 50Hz Test Set-up: Table-top Equipment All emissions not reported here are more than 10 dB below the prescribed limit. ■...
Page 39
Test Report: CE03111004-A Issued date: Dec. 16, 2003 39 of 39 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Page 40
Test Report: CE03111004-A Issued date: Dec. 16, 2003 40 of 40 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Page 41
Test Report: CE03111004-A 19.1.5 Test Mode 6 (CH 13g@ 54Mbps Bit - Rate) Relative Humidity: 70 % Temperature: 24°C Test Date: Nov. 28, 2003 Power Supply System: AC Power: 230Vac 50Hz Test Set-up: Table-top Equipment All emissions not reported here are more than 10 dB below the prescribed limit. ■...
Page 42
Test Report: CE03111004-A Issued date: Dec. 16, 2003 42 of 42 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Page 43
Test Report: CE03111004-A Issued date: Dec. 16, 2003 43 of 43 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Test Report: CE03111004-A 19.2. Photographs of Conducted Powerline Test Configuration The photographs show the configuration that generates the maximum emission. FRONT VIEW REAR VIEW Issued date: Dec. 16, 2003 44 of 44 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Test Report: CE03111004-A 20. Test Result of Radiated Emission 20.1. Test Mode 1 (TX / RX @ 11Mbps Bit – Rate) Relative Humidity: 70 % Temperature: 24°C Test Date: Nov. 28, 2003 Power Supply System: AC Power: 230Vac 50Hz Test Set-up: Table-top Equipment All emissions not reported here are more than 10 dB below the prescribed limit.
Page 46
Test Report: CE03111004-A 20.1.1 Test Mode 2 (TX / RX @ 54Mbps Bit - Rate) Relative Humidity: 70 % Temperature: 24°C Test Date: Nov. 28, 2003 Power Supply System: AC Power: 230Vac 50Hz Test Set-up: Table-top Equipment All emissions not reported here are more than 10 dB below the prescribed limit. ■...
Test Report: CE03111004-A 20.2. Photographs of Radiated Emission Test Configuration The photographs show the configuration that generates the maximum emission. FRONT VIEW REAR VIEW Issued date: Dec. 16, 2003 47 of 47 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Test Report: CE03111004-A 22. Voltage Fluctuations Test Basic Standard : EN 61000-3-3:1995/A1:1998 Temperature : 25 ℃ FINAL TEST RESULT : PASS Test Data : Nov. 28, 2003 Relative Humidity : 50 % RH Dc ( % ) Dmax ( % ) Dt ( % ) Reading 0.070...
Test Report: CE03111004-A 22.2. Photographs of Harmonics test, Voltage Fluctuation and Flicker test Harmonics test Flicker test Issued date: Dec. 16, 2003 50 of 50 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Test Report: CE03111004-A 23. Electrostatic Discharge Immunity Test (ESD) Final Test Result PASS Pass performance Criteria TT/TR Required performance criteria : TT/TR Basic Standard EN 61000-4-2:1995/A1:1998/A2:2000 Product Standard EN 301 489-17 Level 3 for air discharge, 2 for contact discharge ±2 / ±4 / ±8 KV for air discharge, Test Voltage ±2 / ±4 KV for contact discharge...
Test Report: CE03111004-A 23.2. Test Result of Air Discharge/ Contact Discharge Energy-Storage Capacitor: 150 Contact Discharge Times: 10 times/each condition Discharge Resistor : 330 Ω Air Discharge Times : 10 times/each condition \Discharge Mode Contact Discharge Air Discharge \ESD Voltage \Points \Result \Polarity Note: ”N”...
Test Report: CE03111004-A 24. Radio Frequency Electromagnetic Field Immunity Test (RS) Final Test Result PASS Pass performance Criteria CT/CR Required performance criteria : CT/CR Basic Standard EN 61000-4-3:1996/A1:1998/A2:2000 Product Standard EN 301 489-17 Level Frequency Range 80-1000 MHz; 1400-2000 MHz Field Strength 3 V/m (Modulated 80% AM) Temperature...
Test Report: CE03111004-A 24.2. Photographs of Radio Frequency Electromagnetic Field Immunity Test Issued date: Dec. 16, 2003 56 of 56 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Test Report: CE03111004-A 25. Electrical Fast Transient/Burst Immunity Test (EFT/BURST) Final Test Result PASS Pass performance Criteria CT/CR Required performance criteria : TT/TR Basic Standard EN61000-4-4:1995/A1:200 Product Standard EN 301 489-17 Level on Power Supply -- ±1.0 KV Test Voltage on I/O signal, data and control line -- ±0.5 KV Temperature 25 °C...
Test Report: CE03111004-A 25.2. Photographs of Electrical Fast Transient/BURST Immunity Test Issued date: Dec. 16, 2003 58 of 58 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Test Report: CE03111004-A 26. Surge Immunity Test FINAL TEST RESULT PASS Pass performance Criteria CT/CR Required performance criteria : TT/TR Basic Standard EN 61000-4-5 :1995/A1:2000 Product Standard EN 301 489-17 Surge wave form (Tr/Th) 1, 2/50(8/20)µs on Signal ports And Telecommunication – N/A Level on Input AC Power Port -- 2 on Signal ports And Telecommunication –...
Test Report: CE03111004-A 27. Conducted Disturbances Induced by Radio-Frequency Field Immunity Test (CS) Final Test Result PASS Pass performance Criteria CT/CR Required performance criteria : CT/CR Basic Standard EN 61000-4-6 :1996/A1:2000 Product Standard EN 301 489-17 Level Test Voltage 3 V rms ( Modulated, 1KHz, 80%, AM ) Frequency Range 0.15 MHz to 80 MHz Dwell time...
Test Report: CE03111004-A 27.3. Photographs of CS Tests Power Line LAN Line Issued date: Dec. 16, 2003 62 of 62 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Test Report: CE03111004-A 28. Voltage Dips and Voltage Interruptions Immunity Tests Final Test Result PASS Pass performance Criteria TT/TR for voltage interruption, CT/CR and TT/TR for voltage dips Required performance criteria TT/TR for voltage interruption, TT/TR for voltage dips Basic Standard EN 61000-4-11:1994/A4:2000 Product Standard EN 301 489-17...
Test Report: CE03111004-A 28.2. Photographs of Voltage Dips and Voltage Interruptions Immunity Tests Issued date: Dec. 16, 2003 64 of 64 Exclusive Certification Corp Tel:886-2-2792-3366 Fax:886-2-2792-1100...
Test Report: CE03111004-A 29. List of Measuring Equipment Used (EMS) Recommended Test Equipment Calibration Date Recal. Date EMC Emission Tester EMC-Partner Harnmonics-1000 Sep.06,2003 Sep.05,2004 EMC Immunity tester\EMC-Partener\TRANSIENT-1000 Oct.17,2003 Oct.16,2004 Metering Unit & Probe\EMCO\7122 Oct.30,2003 Oct.29,2004 SMGL Generator\Agilent\83640B Jun.23,2003 Jun.22,2004 Amplifier\ar\50S1G4AM1 Jun.23,2003 Jun,22,2004 Test System : FRANKONIA EMV-Mess-System GmbH\CIT-10...
Need help?
Do you have a question about the TEW-431BRP and is the answer not in the manual?
Questions and answers