iii.
Check the cleaved the end face of the fiber with the cover open.
<Φ250 type>
iv.
Remove the cleaved fiber and holder.
Be careful not to leave any dust or foreign substance on the fiber.
Cleaved chips are collected by an automatic chip collector.
For the detailed use of cleaver, refer to the instructions for blade use.
4.7.1
Blade adjustment and replacement
- 1~16 channels are shown on the blade. (Cleaving locations).
- When the cleaving is not normally done, wash the blade's edge and rubber pad both
at the top and the bottom with cotton swab moistened with alcohol. (Do not use
acetone or solvent when cleaning the rubber pad.)
- If cleaving continuously fails, change the channel or replace the blade as the life of
the blade has ended.
<Connector type>
24