Elsner KNX PS640+ Installation And Adjustment

Power supply systems with bus functions

Advertisement

Quick Links

Power Supply Systems
KNX PS640+ and KNX
PS640+USB
with bus functions
Installation and Adjustment
Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik
Herdweg 7 D-75391 Gechingen Deutschland
Phone.: +49 (0) 70 56/93 97-0 Fax: +49 (0) 70 56/93 97-20
info@elsner-elektronik.de www.elsner-elektronik.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KNX PS640+ and is the answer not in the manual?

Questions and answers

Summary of Contents for Elsner KNX PS640+

  • Page 1 Power Supply Systems KNX PS640+ and KNX PS640+USB with bus functions Installation and Adjustment Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik Herdweg 7 D-75391 Gechingen Deutschland Phone.: +49 (0) 70 56/93 97-0 Fax: +49 (0) 70 56/93 97-20 info@elsner-elektronik.de www.elsner-elektronik.de...
  • Page 2: Table Of Contents

    Setting of parameters (Software ETS) ................ 11 General settings ..........................11 Messages ............................12 Current threshold value ........................14 KNX PS640+ und KNX PS640+USB from software version 1.01, ETS programme version 1.1 Version: 15.05.2013. Errors excepted. Subject to technical changes.
  • Page 3: Product Description

    Product description The Power Supply Systems KNX PS640+ and KNX PS640+USB deliver a 29 V bus voltage for the KNX system and 24 V DC supply voltage for 24 V devices. Special operating conditions such as short circuit, electrical surge, overcharge or excess temperature are recorded and may be read off on the display.
  • Page 4: Installation And Commissioning

    The power supply system must only be operated as stationary system, i.e. only in a fitted state and after completion of all installation and start-up works, and only in the environment intended for this purpose. Elsner Elektronik does not assume any liability for changes in standards after publication of this instruction manual.
  • Page 5: Installation

    Input operating voltage 230 V AC, L / N / PE USB interface (only KNX PS640+USB) Output direct current voltage 24 V DC, + / - Connections 4 and 6 are suitable for solid conductors up to 1.5 mm²...
  • Page 6: Settings Of The Device

    Connection example for a KNX system without line coupler Connection example for a KNX system with line coupler Settings of the device Starting position elsner elektronik KNX Power Supply Normal Operation Diagnostics > The following may be read off and set on the display of the Power Supply System KNX...
  • Page 7: Line Reset

    The display is dimmed after 60 seconds if during this period no key is pressed. Line reset In starting position, press key once. elsner elektronik KNX Power Supply Normal Operation Diagnostics > Press key once more in order to get into the sector Line Reset >...
  • Page 8: Operating Data

    With key you return to the previous menu level. was detected 0 times! Operating data In starting position, press key once. elsner elektronik KNX Power Supply Normal Operation Diagnostics >...
  • Page 9: Language

    Temperature on the circuit board of the device are displayed. With key you return to the previous menu level. Language In starting position, press key once. elsner elektronik KNX Power Supply Normal Operation Diagnostics > Move the cursor (flashing rectangle at right edge) to Line Reset >...
  • Page 10: Listing Of All Communication Objects

    Listing of all communication objects Name Function EIS type Flags Bus voltage [V] Output 14.030 C R T Bus current [mA] Output 9.021 C R T Permanent reset (1 = active | 0 = inactive) Input 1.003 C R W Time reset Input 1.003...
  • Page 11: Setting Of Parameters (Software Ets)

    Setting of parameters (Software ETS) General settings Measured values: …………………………… Transmission behaviour object “bus voltage” do not send • send cyclically • send in case of change • send in case of change and cyclically Sending cycle 5 sec 10 sec 30 sec 1 min … 2 h (only if sending “cyclically”) Change in % 1 …...
  • Page 12: Messages

    Reset of the linie: …………………………… What shall be used for the reset? display and keyboard object “permanent reset” No Yes 1 = reset | 0 = no reset object “time reset” No Yes 1 = 30 seconds reset | 0 = no reset Use object “reset status of the line”...
  • Page 13 Sending cycle 5 sec 10 sec 30 sec 1 min … 2 h (only if sending “cyclically”) Object “external overvoltage” [The setting options are similar to object “overload”] Object “internal overvoltage” [The setting options are similar to object “overload”] Object “short circuit” [The setting options are similar to object “overload”] Object “overtemperature”...
  • Page 14: Current Threshold Value

    threshold value has been exceeded for 1 minute. The bit is immediately deleted again, if the threshold value is underrun. Error log: …………………………… Use error log No Yes If the error log is used: Object “message part 1” sends signal: Error no.
  • Page 15 Threshold value in mA 0 … 640 Hysteresis of the threshold value in % 0 … 50 If the threshold value is set by communication object: Threshold value is set by Communication object The value communicated last shall be maintained •...
  • Page 16 Evaluation of the blocking object if value 1: block | if value 0: release • if value 0: block | if value 1: release Value of the blocking object 0 • 1 before 1. communication Bahaviour of switching output with blocking do not send telegram •...

This manual is also suitable for:

Knx ps640+usb

Table of Contents