6.2. Connecting Modem
The Unit is connected the modem.
6.2.1. Connecting Coaxical Cable.
The Unit receives the reference and the IF signal and is required to supply
+15 to +30 V DC power from the modem via coaxial cable.
When connecting the coaxial cable from the modem, follow the following
steps:
Step 1:
Step 2:
NJT5669/70/75/77 series Instruction Manual
Connect the coaxial cable with the N or F-type male connectors
to the coaxial connecter equipped with the Unit which is shown
in a figure below under 0.68 to 1.13 N・m torque.
Supplied the IF/Ref./DC Power via Coaxial Cable
Location of Coaxial Connector
Use self-amalgamating tape to seal connector and cable entry
points from the connector to the cable sheath.
Only input a voltage within the range indicated in specified
voltage.
DO operate at the input voltage of +15 to +30 V DC power at
the coaxial connecter on the Unit.
DO NOT input an IF signal over the range of +13 dBm
maximum and a reference signal within the range of -5 to +5
dBm.
IM-T5669 Rev.01