4.0 Technical data

Model
Nominal output at 80/60ºC
Nominal output at 50/30ºC
Nominal input (nett)
Nominal input (gross)
Efficiency (gross)
Efficiency (nett)
Maximum Gas firing rate
natural gas
Minimum Gas inlet pressure
natural gas
Maximum Gas firing rate
propane
Minimum gas inlet pressure
propane
Maximum flow temperature
Maximum operating pressure
Cold fill pressure
Safety valve size required
Weight (empty)
Water content
Permissible flue system
classifications
CO
2
CO
NOx emissions max
NOx Class
Flue gas temperature (at 20ºC
ambient)
Dew point temperature
Condensate pH
Surplus flue pressure
Power supply
Power consumption
Protection class
Measured at 1
metre away
from boiler
Acer
60
kW
kW
15-60
kW
14-55
kW
15-61
%
%
109
m³/h
5.9
mbar
m³/h
2.3
mbar
°C
bar
bar
kg
l
%
ppm
<50
ppm
<15
°C
°C
Pa
150
V
230V / 50Hz / 1ph via on/off Isolator fused at 6 Amp
W
375
Maximum
dBA
45
Minimum
dBA
35
Acer
Acer
80
100
55
73
90
20-80
25-100
18-74
23-92
20-82
25-102
98
98
98
109
109
7.9
9.8
3.05
3.8
¾˝
¾˝
¾˝
46
73
78
3.9
5
6.5
B23, C13X, C23X, C33X, C43X, C53X, C63X, C83X
<50
<50
<15
<15
200
250
375
375
45
50
35
35
P a g e 8
Acer
Acer
120
150
109
136
30-120
36-150
27-111
34-138
30-123
38-154
98
98
109
109
11.8
14.7
20
4.6
5.73
35
90
6
1.5
¾˝
¾˝
83
92
8.3
10.4
9
<50
<50
<15
<15
5
85
53
4 – 5.5
250
300
375
460
IP44
50
50
35
35
Acer
180
163
45-180
43-166
48-184
98
109
17.6
6.84
¾˝
101
12.9
<50
<15
300
460
50
35