8. MAINTENANCE
8.1.
Clean and lubricate on a regular basis.
8.2.
Regularly check oil level via filler hole (fig 3A). With ramp fully down remove filler plug, oil should be approximately 15mm below the filler
hole. Remove filler plug and grommet, top-up as necessary, then replace grommet and filler plug. Use a good quality jack oil such as Sealey
Hydraulic Jack Oil. DO NOT use brake fluid. DO NOT overfill.
8.3.
Ensure no dirt enters hydraulic system when filling or removing/replacing components.
8.4.
Lubricate the air motor with a good quality jack oil such as Sealey Hydraulic Jack Oil, once or twice a month. Add the oil through the air
valve whilst holding down the lever.
8.5.
Always dispose of waste oil according to local authority guidelines. If in doubt consult your local authority.
8.6.
Keep the lift clean and wipe off any oil or grease. Lubricate all moving parts.
8.7.
Before each use check all parts. If any part of the lift is damaged or suspect, remove the lift from service and take necessary action to
repair.
9. TROUBLESHOOTING
Lift will not lift load.
Lift will not lift load.
Lift will not lift smoothly
or to full height.
Lift will not lower completely.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk or 01284 757505. Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
1. Release valve not fully closed.
2. Oil level low.
3. Air supply low.
1. Release valve not fully closed.
1. Oil level low.
2. Air in hydraulic system.
1. Release valve not sufficiently open.
MC680A
01284 703534
sales@sealey.co.uk
Original Language Version
1. Close valve firmly.
2. Top-up to correct level.
3. Min. requirement 100psi.
1. Close valve firmly.
1. Top-up to correct level.
2. Bleed system.
1. Slowly open valve further.
www.sealey.co.uk