  • Page 1 BELT DRIVEN AIR COMPRESSORS PRODUCT MANUAL BEFORE OPERATION SHOULD BE FAMILIAR WITH THE PRODUCT MANUAL FIRST 1 / 10 pages...
  • Page 2: Important Notice

    IMPORTANT NOTICE THINGS TO BE DONE BEFORE OPERATING YOUR NEW AIR COMPRESSOR FOR THE FIRST TIME 1. On the top front of the air compressor pump head, you shall find a Red Oil Filling Plug, loose the Red Oil Filling Plug, then start to adding lubricating oil from this hole, the lubricating oil shall be designated by the manufacturer or the authorised dealer, the lubricating oil shall reach the halfway mark in the Oil Indicator Glass.
  • Page 3: Safety Guidance

    1. INTRODUCTION Read this manual carefully before operating or servicing the air compressor, to familiarize yourself with proper safety, operation and maintenance procedures. FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS PRODUCT MANUAL COULD RESULT IN PERSONAL INJURY, PROPERTY DAMAGE AND OR VOIDING YOUR WARRANTY. Following the instruction in this manual will make your air compressor runs safer with longer product life.
  • Page 4: Operating Principle

    the tools. High temperatures and moving parts are present in the air compressor, to prevent burns or other injuries, Do not operate the air compressor with the fence cover. Allow the air compressor to cool down before handling or servicing. 10) Be certain to red all labels when you are spraying paints or toxic materials, and follow the safety instructions.
  • Page 5 5. TECHNICA PARAMETERS Exhaust Rated Tank Power Cylinder Pressure Noise Volume MODEL Voltage Capacity (dB) (Liter) 102-1201 V-0.12/8-50L Φ51*2 ≤70 240/50 102-1202 V-0.12/8-70L Φ51*2 ≤70 240/50 102-1203 V-0.12/8-90L Φ51*2 ≤70 240/50 102-1204 V-0.17/8-70L Φ51*2 ≤70...
  • Page 6 102-1214 W-0.36/8-300L Φ65*3 415/50 ≤90 102-1215 V-0.6/8-230L Φ90*2 ≤100 415/50 102-1216 V-0.6/8-300L Φ90*2 ≤100 415/50 102-1217 V-0.6/8-400L Φ90*2 ≤100 415/50 102-1218 W-0.67/8-300L Φ80*3 ≤100 415/50 102-1219 W-0.67/8-400L Φ80*3 ≤100 415/50 102-1220 W-0.67/8-500L Φ80*3 ≤100 415/50 102-1221 W-0.9/8-300L Φ90*3 ≤110 415/50 102-1222 W-0.9/8-400L Φ90*3 ≤110 415/50...
  • Page 7 102-1235 V-0.25/12.5-120L Φ65*1,Φ51*1 12.5 240/50 ≤80 102-1236 V-0.25/12.5-180L Φ65*1,Φ51*1 12.5 240/50 ≤80 102-1237 V-0.25/12.5-230L Φ65*1,Φ51*1 12.5 240/50 ≤80 102-1238 W-0.36/12.5-120L Φ65*2,Φ51*1 12.5 415/50 ≤90 102-1239 W-0.36/12.5-180L Φ65*2,Φ51*1 12.5 415/50 ≤90 102-1240 W-0.36/12.5-230L Φ65*2,Φ51*1 12.5 415/50 ≤90 102-1241 W-0.36/12.5-300L Φ65*2,Φ51*1 12.5 415/50 ≤90 102-1242 V-0.6/12.5-180L...
  • Page 8 102-1256 W-1.6/12.5-400L 1600 12.5 ≤130 415/50 Φ100*2,Φ80*1 102-1257 W-1.6/12.5-500L 1600 12.5 ≤130 415/50 Φ100*2,Φ80*1 6. QUALITY ASSURANCE AND WARRANTY POLICY: From the date of purchase based on in invoice date, product assurance is 12 months. Due to the failure of manufacturing defects, the Company will be in strictly accordance with the following warranty for the users: Quality assurance is only valid in the following circumstances: Users is operating and maintaining the product properly in accordance with the Product Manual.
  • Page 9 Illustrating model:: V-0.17/8-90L Oil filling plug Pump head Silencer Pressure switch Motor Ball valve Pressure meter Handle Safety valve One-way check valve Air receiver tank Wheel Illustrating model:: W-0.9/8-300L Pump head Oil filling plug Silencer Pressure switch and meter Motor Safety valve Ball valve D.O.L Starter...
  • Page 10: Toubleshooting

    9. TOUBLESHOOTING Trouble Phenomenon Reasons Troubleshooting Method 1. problem in the power supply or 1. Check the power supply voltage not sufficient 2. Replace the cable The motor cannot 2. Power cable too thin or too 3. check the pressure switch4. running ,running too slow or long 4.