Sealey SA206 Instructions page 2

Air regulator, filter, lubricator range

Advertisement

filter/regulator - Sa206fr, Sa206fraD
max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)
max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)
max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . .140cfm
filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron
Ports-inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2"BsP
outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2"BsP
Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4"BsP
Auto drain . . . . . . . . . . . . . . . . . . . . . . . . . . sA206frAd only
regulator - Sa206r
max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)
max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)
max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . .210cfm
Ports-inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2"BsP
outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2"BsP
Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4"BsP
4. content & inStallation
4.1.
confirm that all items are present and undamaged. if any parts are missing or damaged please contact the supplier.
sA206 - combined filter, regulator with gauge, lubricator and mounting bracket.
sA206fr - combined filter, regulator with gauge and mounting bracket.
sA206f - filter.
sA206l - lubricator.
sA206r - regulator with gauge and mounting bracket.
sA206fAd - filter with Auto drain,
sA206frAd - combined filter with auto drain, regulator
with gauge and mounting bracket.
4.2.
fig.1 shows a typical air line installation. the filter is located
upstream of the regulator - unless combined, as in sA206
and sA206fr - and the lubricator downstream.
4.3.
filter/regulator - install using the mounting bracket provided.
Before connecting system piping ensure that gauge is visible,
unused gauge port is sealed with plug provided and that flow
direction arrow matches system air flow.
filter and lubricator - install into air piping or connect directly to bracket mounted regulator using fittings provided. Always check that
flow arrows are correct and that filter is upstream, and lubricator downstream, of regulator.
note: to ensure air-tight joints, use Ptfe tape.
5. operation
5.1.
regulator - the output pressure is controlled by the knob. Before pressurising the air system for the first time, pull out and rotate
the knob anticlockwise to remove any loading on the regulator spring. Pressurise the system and then rotate knob clockwise to set
required output pressure, as shown on gauge. When the required pressure is achieved push in knob to prevent inadvertent
adjustment.
note: for correct pressure setting always adjust up from a lower pressure. therefore to reset from 90 to 70psi for example, reduce
pressure from 90 to 60psi and then increase to 70psi.
5.2.
filter - the bowl should be drained regularly to prevent an excessive build-up of water/oil. Pull down the drain valve at the bottom of
the bowl, allow to drain and then release. drain valve has female 1/8" BsP outlet. (sA206frAd and sA206fAd have Auto drain
feature. When pressure in bowl drops, float valve opens and drains condensation. drain valve has male 1/8" BsP outlet).
5.3.
lubricator - remove the filler plug (fig.2.A) and fill bowl up to max. level, with air tool oil. this can be done with the air line pressurised.
With air flowing through the lubricator the oil delivery rate can be adjusted by screw (fig.2.c) whilst watching the drip rate
through the sight dome (fig.2.B). the oil delivery rate will automatically increase or decrease in line with the air flow.
5.4.
Both the filter and the lubricator are supplied with a metal bowl guard. to remove the guard, pull down the latch (fig.3.d) and rotate
the guard until either of the two pairs of lines (fig.3.e) on the guard align with the similar marks (fig.3.f) on the head. the guard can
now be removed.
to refit, slide the top of the guard into the head with the guard and head markings aligned, and the rotate the guard so that the latch
aligns with the marks on the head. the latch will lock into place.
© Jack sealey limited
fig.2
Original Language Version
filter - Sa206f, Sa206faD
max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)
max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)
max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . .140cfm
filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron
Ports-inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2"BsP
outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2"BsP
Auto drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . sA206fAd only
Warning! filter and lubricator bowls are manufactured
from polycarbonate and must not be used at temperatures
over 125°f (52°c) or for pressures over 218psi (15 bar).
polycarbonate can be damaged and may fail if exposed to
certain solvents either internally or externally - strong
alkalies, compressor oils containing aromatic hydrocarbons
or fire retardant oils, or the fumes of any of these. clean
with warm water only.
fig.1
fig.3
sA206/206fr/206f/206l/206r/206fAd/206frAd | issue 4 04/05/17