Download Print this page

Sealey AUTOCHARGE200HF Instructions page 3

Compact auto smart charger (2a, 6/12v)

Advertisement

4.1.
mode Description.
mode indicator light
6V NORM
12V NORM
AGM/GEL
12V SMALL 0.8A
12V LITHIUM IRON
12V RECOND
4.2.
9 stage chargINg.
Stage 1: Desulphation: Pulses of current and voltage.
Stage 2: Battery charge to 25% capacity using 50% constant current.
Stage 3: Battery charge to 50% capacity using max. current.
Stage 4: Battery charge to 75% capacity using constant voltage.
Stage 5: Analysis: Analysing power capacity.
Stage 6: Recond: If power capacity is low use Recond to attempt recovery.
Stage 7: Battery charge to 100% capacity using constant voltage.
Stage 8: Diagnosis: Check battery for 100% charged.
Stage 9: Maintenance: Battery fully charged.
4.3.
coNNectINg to the BatterY.
Note: the charger should be connected to the mains supply before connecting to battery.
4.3.1.
The output cable from the charger terminates in a polarity conscious socket into which the two alternative leads can be connected.
4.3.2.
one lead set has two colour coded battery clamps which can be quickly attached to and detached from the battery posts.
The second lead is for semi permanent connection to the battery via eyelets.
4.4.
chargINg a NegatIVe eartheD BatterY.
4.4.1.
ensure that the black clamp on the clamp lead is not touching the battery or the fuel line.
4.4.2.
Connect the positive (+) red clamp to the positive (+) battery post and connect the negative (-) black clamp to the negative (-) battery
post or vehicle chassis.
4.5.
chargINg a posItIVe eartheD BatterY.
4.5.1.
ensure that the red clamp on the clamp lead is not touching the battery or the fuel line.
4.5.2.
Connect the negative (-) black clamp to the negative (-) battery post and connect the positive (+) red clamp to the positive (+) battery
post or vehicle chassis.
4.6.
BatterY Not coNNecteD to a VehIcLe.
4.6.1.
Connect the (+) red clamp to the positive (+) battery post and connect the (-) black clamp to the negative (-) battery post.
4.7.
permaNeNt coNNectIoN to VehIcLe usINg eYeLet LeaD.
4.7.1.
Connect the eyelet on the red (+) wire to the positive (+) battery terminal and connect the eyelet on the black (-) wire to the negative (-)
battery terminal.
4.8.
chargINg moDe seLectIoN (see chart sectIoN 4.1).
4.8.1.
Choice of charging mode depends on battery rated voltage and battery type.
4.8.2.
Immediately the unit is powered on, cycle through charging mode options by depressing the Mode button (fig.1 Item 4). When the
required option is highlighted hold the Mode key down for 5 seconds and required charging will begin. Charge level is indicated by the
display LED sequence (fig.1 Item 2).
4.8.3.
When charging is complete disconnect the unit from the mains power supply before disconnecting from the battery.
5. trouBLeshootINg
symptom
no reaction when powered on.
Power indicator On - no charging occurring.
(fig.1 - item 3).
© Jack Sealey limited
Charging status
6V normal mode
12V normal mode
12V WINTER MODE
12V MAINTAIN MODE
12V Lithium battery mode
12V RECOVER MODE
solution
Check mains connection and power supply.
Return to Sealey stockist.
Check clamp connections to battery.
Check for broken clamp cables.
Original Language Version
Applicable battery capacity
1.3 - 60Ah
1.3 - 60Ah
1.3 - 60Ah
1.3 - 60Ah
1.3 - 60Ah (LPF)
AUTOCHARGE200HF
Issue 1 22/08/18

Advertisement