GE Lumination LUR Series Installation Manual page 9

Led
Table of Contents

Advertisement

LED Light Engine 1
Connect
BLACK (line)
to Existing
WHITE (neutral)
Power
PURPLE (0-10V dimming+)*
GRAY (0-10V dimming-)*
*Connect 0-10V dimming (purple and gray) wires to dimming controllers, sensors, etc. Cap these wires if not in use.
**When connecting two 4ft LED light engines to one 90W GE driver.
15
If not already connected, insert the blue wire from the GE LED driver into position "1" and the red wire into position
"2" of the DC connector. Insert the black wire from the LED light engine into a position "1" and the red wire into
the corresponding position "2" of the other half of DC connector (left). If the wires are long/very visible, push extra
length back through the grommets. Ensure that wiring matches wiring diagram shown.
NOTE: If connecting two 4ft LED light engines to one GE 90W LED driver, ensure that the light engines are oriented
such that the black and red wires of both light engines reach the DC connector; connect the black and white red
from the second light engine into the two remaining positions in DC connector (right).
NOTE: For single 4ft LED light engines, must connect with provided GE 50W LED driver with a red label, as shown in
the image below.
GE Driver
LED Light Engine 1
LED Light Engine 2
BLUE
GE Driver
RED
9
BLACK
Light Engine 1
RED
BLACK
Light Engine 2**
RED
GE Driver

Advertisement