Check Operation; Gas And Electrical Connection; Electronic Ignition System - Whirlpool Freestanding Gas Range Installation Instructions Manual

30" (76.2 cm) freestanding gas range with standard clean oven
Table of Contents

Advertisement

7.
Making sure the anti-tip bracket is
installed:
• Look for the anti-tip bracket securely
attached to floor.
• Slide range back so rear range foot is
under anti-tip bracket.
anti-tip
bracket
8.
If installing the range in a mobile
home, you must secure the range to the
floor. Any method of securing the range
is adequate as long as it conforms to the
"Manufactured Home Construction and
Safety Standard, " Page 2.
9.
Place rack in oven. Place level on
rack, first side to side; then front to back.
If range is not level, pull range forward
until rear leveling leg is removed from
the anti-tip bracket. Use 3/8" drive ratchet
and channel lock pliers to adjust leveling
legs up or down until range is level. Push
range back into position. Check that rear
leveling leg is engaged in anti-tip bracket.
NOTE: Oven must be level for satisfactory
baking conditions.
Gas and electrical
connection
10.
Assemble the flexible connector
to the gas supply pipe to the pressure
regulator connection fitting, using the
adapter fittings provided with the flexible
connector. Use pipe-joint compound
made for use with L.P . gas to seal all pipe
thread connections.
6
All connections must be wrench-tightened.
Typical
rigid pipe
connection
range foot
Typical flexible
connection
A 1/2" male pipe thread is needed for connection
to pressure regulator female pipe threads.
11.
is used, be certain connector is not
kinked.
12.
in the "OFF" position.
regulator
connection
fitting
90˚elbow
pressure regulator
connection fitting
union
manual
gas
shutoff
nipple
valve
1/2" to 3/4"
gas pipe
pressure regulator
connection fitting
use pipe-joint
compound
adapter
use
pipe-joint
compound
adapter
1/2" to 3/4"
gas pipe
If a flexible appliance connector
Check that all control knobs are
13.
Check that range regulator
shutoff valve is in the "on" position. Open
the manual shutoff valve in the gas
supply line.
black iron
pipe
manual shutoff valve
"open" position
to range
flexible
connector
14.
Test all connections by brushing
manual
on an approved non-corrosive leak-
gas
detection solution. Bubbles will show a
shutoff
leak. If a leak appears, shut off gas supply
valve
valve and tighten connections. Then check
connections again. Clean all leak-
detection solution from gas connections.
Close broiler door.
15.
Place burners, burner caps and
grates on cooktop.
16.
Plug power supply cord into
grounded electrical outlet.

Check operation

Electronic ignition system

Cooktop and oven burners use electronic
ignitors in place of standing pilots. When
a cooktop control knob is turned to the
"LITE" position, the system creates a
spark to light the burner. This sparking
continues until the control knob is turned
to the desired setting.
When the oven control is turned to the
desired setting, a hot surface ignitor
heats to a bright orange and ignites the
gas. No sparking occurs. The glow bar
remains on while the burner operates.
viewed from
inside broiler
compartment
regulator shutoff
valve in
"on" position
gas supply

Advertisement