fluidra Certikin CUV15V3 Installation And Operating Manual

Uv disinfection system

Advertisement

CUV-SC111020201MAN
UK / EU / USA
UV DISINFECTION SYSTEM
CUV15V3, CUV25V3, CUV30V3, CUV55V3, CUV75V3, CUV110N, CUV220N
INSTALLATION AND OPERATING MANUAL
• Ensure that the unit is switched off at the mains before you attempt to conduct
any type of maintenance on the CUV.
• Ensure the unit is installed in the recommended orientation.
• Fit the quartz sleeves and O-rings and switch on pump to check that unit is water
tight before fitting the bulb, bulb socket and end cap, see pages 9 to 14.
• Ensure that the end cap is tight before running the unit.
• After replacing bulbs or before tightening the end cap, make sure that the O-Rings
are in the correct position, and the bulb sockets are dry.
• If the electrical connections get wet, dry thoroughly before switching power on.
This unit should only be installed by a qualified electrician.
Witan Park, Avenue 2, Station Lane Industrial Estate, Witney, Oxfordshire, United Kingdom, OX28 4FJ
Phone: +44 (0) 1993 777200 | Fax: +44 (0) 1993 778869 | www.certikin.co.uk
WARNING:
CERTIKIN INTERNATIONAL LTD.
Affix serial number here

Advertisement

Table of Contents
loading

Summary of Contents for fluidra Certikin CUV15V3

  • Page 1 CUV-SC111020201MAN UK / EU / USA Affix serial number here UV DISINFECTION SYSTEM CUV15V3, CUV25V3, CUV30V3, CUV55V3, CUV75V3, CUV110N, CUV220N INSTALLATION AND OPERATING MANUAL WARNING: • Ensure that the unit is switched off at the mains before you attempt to conduct any type of maintenance on the CUV.
  • Page 2 WARNING: PLEASE READ THE FOLLOWING SAFETY INFORMATION FIRST. IMPORTANT SAFETY INFORMATION - This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 3: Table Of Contents

    INTRODUCING THE CERTIKIN UV DISINFECTION SYSTEM Congratulations on purchasing a Certikin UV disinfection system. Our range of UV sterilisers have been manufactured using the latest technology and design techniques. The UV will work alongside many different filtration systems designed in combination with a residual sanitiser to disinfect pool water. Please read this instruction manual carefully from start to finish before attempting to install your UV.
  • Page 4: Uv Diagram And Components List

    CUV 15W AND 25W DIAGRAMS AND COMPONENTS LIST Please familiarise yourself with the components shown in the diagram below: (C) (D) (H) Description Diagram Code CERTIKIN Order Code Threaded Pipe Union 1.5" End Cap SPCUVEC UV Bulb Available from your dealer* Quartz Sleeve Available from your dealer* Bulb Socket...
  • Page 5 CUV 30W TO 75W DIAGRAMS AND COMPONENTS LIST Please familiarise yourself with the components shown in the diagram below: (C) (D) (H) Description Diagram Code CERTIKIN Order Code Threaded Pipe Union 1.5" End Cap SPCUVEC UV Bulb Available from your dealer* Quartz Sleeve Available from your dealer* Bulb Socket...
  • Page 6 CUV 110 WATT DIAGRAMS AND COMPONENTS LIST Please familiarise yourself with the components shown in the diagram below: (C) (D) (H) Description Diagram Code CERTIKIN Order Code 2" Slip Fitting End Cap SPCUVEC UV Bulb Available from your dealer* Quartz Sleeve Available from your dealer* Bulb Socket SPCUVLH...
  • Page 7 220 WATT DIAGRAMS AND COMPONENTS LIST Please familiarise yourself with the components shown in the diagram below: (C) (D) (H) Description Diagram Code CERTIKIN Order Code 2" Slip Fitting End Cap SPCUVEC UV Bulb Available from your dealer* Quartz Sleeve Available from your dealer* Bulb Socket SPCUVLH...
  • Page 8: Flow Rates

    FLOW RATES Please note: For optimum performance we recommend that you pass the entire volume of your pool through the CUV unit at least once every 4 to 8 hours. The slower the flow the higher the dosage of UV. We do not recommend the use of pumps with operating pressures in excess of 2.5 bar / 25 metres of head.
  • Page 9: Installing The Quartz Sleeve

    INSTALLING THE QUARTZ SLEEVE Quartz End Cap Sealing Ring (I) Sleeve Locking O-Ring (G) Bulb Socket (F) Nut (H) End Cap (B) UV Bulb (C) Quartz Thread Sleeve (D) Body 1. Starting at one end of the unit, unscrew the black end cap (B). You will notice that this black end cap houses the bulb socket (F).
  • Page 10: Positioning And Mounting The Cuv

    POSITIONING AND MOUNTING THE CUV For best performance, we recommend installing the CUV in a horizontal orientation. Mounting brackets Mounting brackets are pre-fitted to the CUV for easy installation (except CUV-110N) PLEASE NOTE: Wall mounting screws and washers are not provided. Fitting the brackets to the CUV-110N Two stainless steel mounting brackets are included.
  • Page 11: Connection To Your Pipework

    CONNECTION TO YOUR PIPEWORK IMPORTANT: Do not overtighten fittings. Please note that there is no correct direction of flow through the unit, either end of the unit may be used as the inlet or outlet. IMPORTANT: Valves positioned after the CUV must never be closed when the pump is in operation.
  • Page 12: Water Testing

    EQUAL AMOUNTS MUST BE VISIBLE EQUAL AMOUNTS MUST BE VISIBLE WATER TESTING THE QUARTZ, O-RINGS AND LOCKING NUTS EQUAL AMOUNTS MUST BE VISIBLE EQUAL AMOUNTS MUST BE VISIBLE Now that the unit is in position and connected to pipework, the quartz sleeve and O-ring at each end can be leak tested to ensure that they have been fitted properly.
  • Page 13: Connection To The Electricity Supply

    CONNECTION TO THE ELECTRICITY SUPPLY Electrical installations must be done by a qualified electrician. The power supply must meet the specifications on the product. The cores in the supply cable are coloured in accordance with the following code: UK / EU: USA WIRING Brown = Live Black = Live...
  • Page 14: Installing The Uv Bulb

    INSTALLING THE UV BULB 1. Remove all packaging from the UV bulb (C). 2. Slide the UV bulb (C) carefully through the quartz sleeve (D) that you have just fitted, as per the instructions on page 9. 3. While holding one of the black end caps (B) gently push the cable through the end cap which will make it easier to fit the bulb socket (F) in step 5.
  • Page 15: Uv Bulb Replacement

    UV BULB REPLACEMENT ALWAYS ISOLATE THE UNIT FROM ANY ELECTRICITY AND WATER SUPPLY BEFORE CARRYING OUT MAINTENANCE ON THE UNIT. TO REMOVE A UV BULB: It is not necessary to stop the water circulating through the CUV to change the bulb. 1.
  • Page 16: Replacing / Cleaning The Quartz Sleeve

    REPLACING / CLEANING QUARTZ SLEEVE DANGER: ULTRAVIOLET RADIATION. Disconnect Power Before Replacing Lamp ALWAYS ISOLATE THE UNIT FROM ANY ELECTRICITY AND WATER SUPPLY BEFORE CARRYING OUT MAINTENANCE ON THE UNIT. TO REMOVE A QUARTZ SLEEVE: PLEASE NOTE: Removing the quartz sleeve will cause water to flow out of the unit. Flow can be directed to the bypass using the installed bypass.
  • Page 17: Control Box Replacement

    CONTROL BOX REPLACEMENT The control box with ballast can be easily replaced in the event of any issues. Spare control boxes are available from your Certikin dealer. Use the installation instructions provided with the spare part to install the unit. IN BUILT PROTECTION The CUV range of UV disinfection system sterilisers have thermal overload protection which automatically shuts down and then enables a fast re-start when...
  • Page 18: Trouble Shooting

    TROUBLE SHOOTING If the UV bulb is not lit, then you need to investigate the power to your unit. • Has your RCD tripped? If yes, check your wiring and reset. • Examine the UV bulb for signs of failure, and replace if necessary. •...
  • Page 19: Frequently Asked Questions

    FREQUENTLY ASKED QUESTIONS How often should I change the UV bulb? The UV bulb has an effective lifespan of 12 months (9000 hours). This should be changed without fail in order for the unit to remain effective and fit for purpose. Is the UV suitable for salt water use? The UV is manufactured from materials that will not corrode in salt water, however the stainless steel bracket will.
  • Page 20: Guarantee

    GUARANTEE This product is guaranteed against defects in material and workmanship for 2 years from the date of purchase, under normal usage. The guarantee DOES NOT APPLY in case of improper use, negligence, lack of maintenance or accidental damage to the UV.
  • Page 22 CERTIKIN INTERNATIONAL LTD. Witan Park, Avenue 2, Station Lane Industrial Estate, Witney, Oxfordshire, United Kingdom, OX28 4FJ Phone: +44 (0) 1993 777200 Fax: +44 (0) 1993 778869 www.certikin.co.uk...