Peri SONO WZ Instructions For Use Manual page 32

Lancehead-shaped probe
Table of Contents

Advertisement

Adjusting and Measuring
Probe info
By selecting this menu item, information
will be provided on the lancehead-shaped
probe.
This includes:
– Name
– Module Code
– Serial No.
– Hardware Version (HW)
– Firmware Version (FW)
Material calibration
By selecting this menu item, the lance-
head-shaped probe can be adjusted to
accommodate another calibration curve.
After switching on the hand-held measuring
instrument, the calibration curve selected
in this menu item is displayed at the bot-
tom of the screen for approx. 3 seconds.
For measuring concrete, the standard
calibration curve "Cal. No. 4" is pre-se-
lected. This setting should not or should
only be changed if another material is
being measured instead of fresh concrete.
A total of up to 15 calibration curves can
be handled for materials such as ceramic
suspension and sludges. Furthermore,
the selection of a different calibration
curve can change the sensitivity of the
concrete measurement.
32
Info
By selecting this menu item, information
is shown about the hand-held measuring
instrument.
This includes:
– Serial No.
– Hardware Version (HW)
– Firmware Version (FW)
– Battery Capacity
– Battery Voltage
Translation of the Original Instructions for Use