2 Safety instructions

The installation and commissioning as well as the connection of electrical components require
technical knowledge commensurate with a recognised vocational qualification as a fitter for
plumbing, heating and air conditioning technology, or a profession requiring a comparable level
of knowledge [specialist]. The following must be observed during installation and
commissioning:
Relevant local and national regulations
Accident prevention regulations of the professional association
Instructions and safety instructions mentioned in this manual
Danger: danger of scalding due to vapour escape!
With pressure relief valves there is risk of scalding due to vapour escape.
During installation, check the local conditions and if a discharge line must
be connected to the safety group. Observe the instructions regarding the
pressure relief valve.
Attention: material damage due to high temperatures!
Install the solar station at a sufficient distance from the collector field,
since the solar fluid may be very hot near the collector. It may be
necessary to install an intermediate tank in order to protect the expansion
tank.
Notice: material damage due to mineral oils!
It is imperative to avoid that the EPDM sealing elements of the station get in
contact with substances containing mineral oils. Mineral oil products cause
lasting damage to the material, whereby its sealant properties are lost.
If necessary, ask the manufacturer whether the solar fluid, greases or
installation aids contain mineral oils.
We do not assume liability nor provide warranty for damage to property
resulting from sealants damaged in this way.
4/20
Installation-Operation Extension Station ST1 TOP - Copyright by Hamworthy
2 Safety instructions
0DNO0202